Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 8 dokumen yang sesuai dengan query
cover
Tri Esti Herbawamurti
Abstrak :
Penelitian pengaruh tanah liat atau clay pada pembuatan briket batubara tanpa karbonisasi dengan komposisi tanah liat sebagai variabel yakni 0%, 5%, 10% dan 15%, telah dilakukan di Laboratorium UPT - LSDE, BPPT. Hasil pengamatan diperoleh uji kuat tekan terhadap briket dengan tanah liat 0% = 5,5 kg/cm2 ; 5% = 9,25 kg/cm2 ; 10% = 12,95 kg/cm2 ; 15% = 16,65 kg/cm2. Dari segi ketahanan dan lama pembakaran menunjukkan briket dengan 0% tidak utuh, runtuh pada menit ke 90; briket dengan tanah liat 5% tidak utuh, runtuh pada menit ke 120; briket dengan tanah liat 10% utuh sampai ke menit 152; briket dengan tanah liat 15% utuh sampai ke menit 122. Analisa emisi gas pada pembakaran briket dengan tanah liat 0% menunjukkan CO rata-rata 434 ppm ; tahah liat 5% CO rata-rata 530 ppm ; tanah liat 10% dengan CO rata-rata 394 ppm dan tanah liat 15% CO rata-rata 386 ppm. Dua variabel atau komposisi tanah liat pertama tidak utuh dan dalam pembakaran tidak bertahan lama serta emisi gas CO lebih tinggi. Sedangkan pada dua variabel terakhir dapat disimpulkan bahwa tanah liat dengan komposisi tanah liat 10% lebih baik.
Research on clay as raw material in producing coal briquette without carbonization has been conducted in laboratory of UPT-LSDE, BPPT. Clay to coal composition that was used as variable was 0%, 5%, 10% and 15%. Result of pressure test of the mixture are as follow: for clay to coal 0% the strength is 5.5 kg/cm2; for clay to coal 5% the strength is 9.25 kg/cm2; for clay to coal 10%, the strength is 12.95 kg/cm2; for clay to coal 15%, the strength is 16.65 kg/cm2. From the view of lifetime and combustion time it was showed that briquette for clay to coal to coal 0% will be broken into pieces in 90 minutes, for clay to coal 5% will be broken into pieces in 120 minutes, or clay to coal 10% will be ruined into pieces in 152 minutes, for clay to coal 15% will be ruined into pieces in 122 minutes. The gas analysis showed that CO gas emission of the briquettes for the five are as follows: 0% of clay was 434 ppm, 5% of clay was 530 ppm, 10% of clay was 394 ppm, and 15% of clay was 386 ppm. The first two compositions is considered as weak, shorter durability and emitted more CO gas emission. Finally, between the last two compositions can be concluded that, that one with 10% of clay is the best.
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2000
T2687
UI - Tesis Membership  Universitas Indonesia Library
cover
Gde Arvindo Anandira
Abstrak :
Fungsi transformator dalam transmisi dan distribusi tenaga listrik semakin penting dewasa ini. Pembebanan pada transformator memengaruhi kondisi transformator dan kinerjanya. Salah satu bagian penting dalam operasi transformator adalah minyak transformator. Untuk memastikan kontinuitas operasi transformator ini, maka kondisi minyak transformator ini juga harus dijaga. Dissolved Gas Analysis (DGA) adalah teknik pengujian minyak transformator. Selama operasi transformator, kondisi minyak transformator dapat menurun ataupun rusak. Tingkat pembebanan transformator sangat memengaruhi kinerja transformator, sehingga kondisi minyak transformator juga berubah seiring perubahan tingkat pembebanan transformator. DGA dapat memberikan gambaran tentang kondisi transformator dan merepresentasikan gangguan yang terjadi pada transformator.
Transformer's role in electric power transmission and distribution is getting more important lately. Transformer loading may affect transformer's operation. Transformer oil is capable of maintaining the operation condition of transformer. In order to ensure that, transformer oil?s condition must be preserved. Transformer oil can be laboratory tested in order to get the overall condition of the transformer. The rate of transformer loading is influential in the operation of transformer that it may affect the condition of the transformer oil. Dissolved Gas Analysis (DGA) is a way to test the transformer oil. During the operation of the transformer, oil?s condition may degrade or fail. This periodic analysis? result could represent the problem occurred to the transformer.
Depok: Fakultas Teknik Universitas Indonesia, 2014
S56983
UI - Skripsi Membership  Universitas Indonesia Library
cover
Muhammad Rifky Raihan Fauzi
Abstrak :
Transformator (trafo) merupakan suatu peralatan tenaga listrik yang berfungsi untuk menaikkan tenaga atau daya listrik dari pembangkit untuk kemudian disalurkan ke Gardu Induk. Minyak isolasi merupakan salah satu komponen isolasi yang sangat penting pada transformator. Selain sebagai isolasi, minyak trafo juga berfungsi melarutkan gas-gas akibat kegagalan thermal dan kegagalan elektris. Mengetahui kandungan gas terlarut dan konsentrasinya perlu dilakukan pemantauan rutin melalui pengujian Dissolved Gas Analysis (DGA). Beberapa gas yang menjadi parameter seperti Hydrogen (H2), Methane (CH4), Ethane (C2H6), Ethylene (C2H4), Acetylene(C2H2), Carbon Monoxide (CO), dan Carbon Dioxide (CO2) serta Air (H2O). Pengujian gas tersebut mengacu pada standar IEEE C57.104-2019. Hasil pengujian DGA dapat digunakan untuk mengidentifikasi indikasi jenis kegagalan pada trafo. ......The transformer (transformer) is an electric power equipment that functions to increase the power or electric power from the generator to then be channeled to the substation. Insulating oil is one of the most important insulation components in a transformer. Aside from being an insulation, transformer oil also functions to dissolve gases due to thermal failure and electrical failure. Knowing the dissolved gas content and its concentration needs to be routinely monitored through the Dissolved Gas Analysis (DGA) test. Some of the gas parameters are Hydrogen (H2), Methane (CH4), Ethane (C2H6), Ethylene (C2H4), Acetylene (C2H2), Carbon Monoxide (CO), and Carbon Dioxide (CO2) and Water (H2O). The gas test refers to the IEEE C57.104-2019 standard. The results of the DGA test can be used to identify indications of the type of failure on the transformer.
Depok: Fakultas Teknik Universitas Indonesia, 2023
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Nafisah
Abstrak :
Pandemi Coronavirus Disease 2019 (COVID-19) telah menjadi masalah kesehatan utama saat ini. Selain gejala respiratorik, pada COVID-19 juga diyakini dapat menyebabkan gangguan pada ginjal dan menyebabkan gangguan asam basa dan elektrolit. Analisa gas darah, elektrolit, dan kreatinin adalah pemeriksaan laboratorium sederhana yang hampir selalu diperiksa pada saat pasien COVID-19 dirawat, tetapi peranannya dalam memprediksi luaran buruk COVID-19 belum banyak diketahui. Luaran buruk pada penelitian ini ialah subjek yang memiliki perawatan di intensive care unit (ICU) dan/atau menggunakan ventilator mekanik dan/atau meninggal. Penelitian ini memiliki desain kohort retrospektif, dengan jumlah sampel 136 subjek. Gangguan asam basa yang tersering adalah alkalosis respiratorik (), sedangkan kelainan elektrolit tersering adalah hiponatremia. Pada penelitian ini didapatkan hubungan yang bermakna secara statistik pada parameter pH, pCO2, PO2, SO2, TCO2, dan kadar natrium. Parameter pH, pCO2, PO2, SO2, TCO2, dan kadar natrium memiliki luas Area Under the Curve secara berurutan sebesar 62,8%; 61,7%; 64,8%; 69,7%; 60,6% dan 73%. Pada analisis regresi logistik, didapatkan suatu model prediksi luaran buruk dengan menggunakan parameter pH, PO2, TCO2, kadar natrium, dan riwayat kardiovaskular. ......Coronavirus Disease 2019 (COVID-19) pandemic has become a major health problem. COVID-19 cause respiratory and kidney problems and cause acid-base and electrolyte disturbances. Blood gas analysis, electrolytes, and creatinine are basic laboratory test that always be examined when a COVID-19 hospitalized, but it’s role in predicting COVID-19 poor outcome is still not clear. The poor outcome in this study was the intensive care unit (ICU) admission and/or using mechanical ventilator and/or died. This study has a retrospective cohort design, with a sample size of 136 subjects. The most common acid-base disorder is respiratory alkalosis, while the most common electrolyte abnormality is hyponatremia. In this study, we found statistically significant association between pH, pCO2, PO2, SO2, TCO2, and sodium levels with COVID-19 poor outcome. The parameter pH, pCO2, PO2, SO2, TCO2, and sodium content have an area under the curve respectively ​​62.8%; 61.7%; 64.8%; 69.7%; 60.6% and 73%. In logistic regression analysis, a model for poor prediction was obtained using pH, PO2, TCO2, sodium levels, and cardiovascular history.
Depok: Fakultas Kedokteran Universitas Indonesia, 2022
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Dewanto Indra Krisnadi
Abstrak :
ABSTRAK
Transformator daya merupakan peralatan dengan investasi terbesar pada sebuah Gardu Induk, oleh karenanya diusahakan sebuah transformator daya dapat berfungsi sesuai dengan perkiraan masa gunanya. Banyak faktor yang mempengaruhi lama masa guna dari transformator, salah satunya adalah memperkirakan kemungkinan terjadinya kegagalan yang diakibatkan karena penurunan sifat isolasi dari isolasi minyak dan kertas.Kegagalan transformator dapat diakibatkan adanya gas-gas yang mudah terbakar didalam kandungan minyak isolasi yang menyebabkan penurun kemampuan isolasi dari isolasi Minyak dan isolasi Kertas. Selain itu pengaruh pembebanan pada pengoperasian transformator daya juga merupakan faktor penting, karena pembebanan dapat menimbulkan panas pada minyak didalam transformator. Dari kedua hal tersebut dibuat sebuah pemodelan tingkat kekritisan transformator daya menggunakan metode logika fuzzy, untuk bisa mendeteksi dini kemungkinan terjadinya kegagalan transformator, sehingga dapat mengurangi risiko penurunan masa guna pada Transformator. Juga didapatkan tren prediksi pengaruh gas terhadap tingkat kekritisan dari gas-gas yang terlarut didalam transformator daya.
The power transformer is the largest invested equipment in a Substation, therefore a power transformer can function in accordance with the estimated useful life. Many factors influence the longevity of the transformer, one of which is to estimate the likelihood of failure resulting from a decrease in the insulating properties of oil and paper insulation.The failure of the transformer may result from the presence of Combustible gases in the insulating oil contents which lead to the lowering of insulation capacity from Oil insulation and Paper insulation. In addition, the loading effect on the operation of the power transformer is also an important factor, since loading may cause heat to the oil within the transformer. From these two things, a model of critical transformer power level using fuzzy logic method is used to detect the possibility of failure of the transformer, thereby reducing the risk of decreasing the life of the Transformer. Also, there is a prediction trend of the effect of gas on the criticality level of the dissolved gases in the power transformer.
Depok: Fakultas Teknik Universitas Indonesia, 2018
D2588
UI - Disertasi Membership  Universitas Indonesia Library
cover
Stefan Heryanto
Abstrak :
Transformator merupakan salah satu peralatan yang tidak dapat dipisahkan dari suatu sistem tenaga listrik. Transformator berfungsi untuk mengubah level tegangan dari daya yang dialirkan tanpa merubah frekuensi tegangan tersebut. Salah satu jenis dari transformator adalah transformator tenaga. Transformator tenaga merupakan transformator yang berfungsi sebagai penyalur daya dari pembangkit ke sistem tenaga listrik. Disini penulis mengambil contoh minyak isolasi dari transformator tenaga yang digunakan untuk transmisi tenaga listrik dengan rating 70 kV. Banyak pengujian yang dapat dilakukan pada minyak transformator untuk mengetahui karakteristik minyak transformator tersebut. Pengujian-pengujian secara garis besar dibagi menjadi pengujian karakteristik dan analisis gas terlarut. Pengujian karakteristik yang digunakan penulis antara lain adalah pengujian tegangan tembus, pengujian tegangan antar muka, pengujian kadar air, pengujian kadar asam (angka kenetralan), dan pengujian warna. Pengujian yang kedua dilakukan dengan metode analisis gas terlarut. Metode ini digunakan untuk mengukur berapa banyak gas yang terlarut di dalam minyak transformator tersebut. Gas-gas yang terdeteksi merupakan indikasi dari terjadinya suatu kerusakan didalam transformator sehingga dengan melihat gas mana yang jauh melebihi batas kita dapat mengetahui kerusakan apa yang ada pada transformator. Berdasarkan analisis dari data-data pengujian tersebut akan ditentukan tindakan yang akan dilakukan pada setiap transformator. ...... Transformer is one of many tools that can not be separated from a power system. Transformer is used to change the voltage level of the transmitted power without changing its frequency level. One example of transformer is a power transformer. Power transformer is a transformer that serves as a supplier of power generation to the power system. Here the authors take the example of the insulating oil of power transformers used for electric power transmission with a rating of 70 kV. Many tests that can be performed on transformer oil to know the characteristics of the transformer oil. Oil tests broadly divided into characteristics tests and dissolved gas analysis. Testing characteristics used by the author, among others, is the breakdown voltage, interfacial tension, water level, acid levels (neutrality number), and color. The second test was conducted using dissolved gas analysis. This method is used to measure how much gas is dissolved in the transformer oil. The gases that were detected point out the occurrence of a fault in the transformer so we can know that there is damage to the transformer when the detected gas is beyond the limit. Based on the analysis of the test data, we must take specified action on each transformer.
Depok: Fakultas Teknik Universitas Indonesia, 2014
S56543
UI - Skripsi Membership  Universitas Indonesia Library
cover
Ramadana Guna Prakasa
Abstrak :
Transformator merupakan mesin listrik stastis yang berperan penting dalam sistem distribusi tenaga listrik yang berfungsi mengatur besar tegangan pada masukan maupun keluaran dari sistem distribusi. Kinerja transformator dipengaruhi oleh kondisi beberapa komponen dasarnya salah satunya adalah isolator minyak yang berfungsi untuk memisahkan dua atau lebih konduktor yang berdekatan untuk mencegah adanya kebocoran arus dan juga sebagi pelindung mekanis. Selain itu minyak isolator dapat membantu dalam memprediksi kegagalan pada transformator dengan mengolah konsentrasi gas gangguan menggunakan metode Dissolved Gas Analysis, yaitu metode Total Dissolved Combustible Gas, Gas Kunci, Rasio Roger, Segitiga Duval, dan Pentagon Duval. Data konsentrasi gas diperoleh dari transformator distribusi yang digunakan pada suatu sistem listrik dalam beberapa perushaan. Melalui pengolahan data menggunakan metode-metode DGA, diperoleh bahwa metode Penatagon Duval merupakan metode paling baik dalam memprediksi kegagalan pada transformator dibandingkan metode lainnya, karena menghasilkan hasil prediksi yang tepat dan spesifik, tidak memiliki syarat yang harus dipenuhi oleh suatu data untuk dapat diolah oleh metode tersebut, dan tidak memerlukan tahap lanjutan dalam menentukkan hasil akhir prediksi.
Transfomer is a static electrical machine that plays important role in power distribution system that serves to set input and output voltage of the system. The performance of the transformer is effected by condition of it components, one of the important components is an isolator oil that works for separate two or more conductors to prevent current leakage and also as a mechanical shielding. In addition, the isolator oil can be use for tools for predicting the failure in the transformer by processing fault gas with dissolved gas analysis method, such as Total Dissolved Combustable Gas, Key gas, Rogers Ratio, Duvals Triangel and Duvals Pentagon. The gas concentration is obtained from distribution transformers that used in electrical system in several firms. By processing fault gas cocentration with DGA methods, it can be concluded that Duvals Pentagon Method is the most excelent method for predicting the failure in transformers since the method predicting results correctly and more specific interm of failure, it doesnt have a condition that must be fulfilled by the data before using this method, and also does not require an advance step in defining prediction result.
Depok: Fakultas Teknik Universitas Indonesia, 2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Thoriksyah Putra
Abstrak :
Transformator daya merupakan salah satu komponen penting dalam sistem tenaga listrik yang paling banyak digunakan. Tingginya pengoperasian pada transformator daya yang dapat menyebabkan kegagalan ini menjadikan pentingnya minyak sebagai komponen isolasi dan pendinginan pada transformator. Minyak transformator akan melarutkan gas-gas akibat kegagalan thermal dan kegagalan elektris. Sejalan dengan hal tersebut, pengujian Dissolved Gas Analysis (DGA) digunakan untuk mendiagnosis kegagalan transformator sebelum terjadi kerusakan yang lebih parah dengan menganalisis indikator gas yang terlarut pada minyak transformator melalui beberapa metode seperti Segitiga Duval, Rasio Doernenburg, Rasio Roger dan IEC.  Namun, berdasarkan pengujian yang dilakukan oleh peneliti sebanyak 688 kasus sampel, tingkat akurasi pendeteksian metode konvensional tersebut masih cukup rendah, yaitu berturut-turut sebesar 85,67%, 75,08%, 47,34%, dan 39%. Hal ini menjadikan metode tiga rasio karya Osama E. Gouda hadir dalam memberikan hasil diagnosis kegagalan transformator lebih akurat sebesar 99,86%. Oleh karena itu, penelitian skripsi ini memiliki tujuan utama dalam membandingkan metode tiga rasio dan metode konvensional yang digunakan pada empat unit transformator daya dalam kasus di PT. Indonesia Power Priok, PT. PLN Persero UPT Siantar, PT. Indonesia Power PLTU Suralaya, dan PT. Indonesia Power PLGU Grati. Harapannya, penelitian ini bukan hanya menganalisis kelayakan kondisi transformator daya, akan tetapi juga dapat memberikan hasil diagnosis kegagalan yang lebih mudah, detail, dan akurat melalui metode Tiga Rasio yang diterapkan di Indonesia. ......Power transformers are one of the most important components in the electric power system. The high operation of power transformers can cause failure, making oil an important component for insulation and cooling system in transformers. Transformer oil will dissolve gases due to thermal and electrical failures. In line with this, Dissolved Gas Analysis (DGA) testing is used to detect transformer failure before more serious damage occurs by analyzing gas indicators dissolved in transformer oil through methods such as the Segitiga Duval, Doernenburg ratio, Roger ratio and IEC. However, based on tests conducted by researchers with 688 sample cases, the detection accuracy of conventional methods is still quite low, namely 85.67%, 75.08%, 47.34%, and 39%. This led to the emergence of the three-ratio method by Osama E. Gouda in providing more accurate transformer failure detection of 99.86%. Therefore, this thesis research has the main aims to analyze for the comparison of the three ratios technique and conventional methods used on four power transformers in a case at PT. Indonesia Power Priok, PT. PLN (Persero) UPT Siantar, PT. Indonesia Power PLTU Suralaya, dan PT. Indonesia Power PLGU Grati. Hopefully, this research not only analyzes the feasibility of power transformer conditions but also provides easier, more detailed, and accurate failure diagnosis results through the three ratios technique applied in Indonesia.
Depok: Fakultas Teknik Universitas Indonesia, 2024
S-pdf