Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 8 dokumen yang sesuai dengan query
cover
Siregar, Leonardus
"The electric power is something that is very important and widely used in supporting human life, but the power is also very dangerous to human safety itself. Low voltage 220 V is part of the electric power distribution system. On this channel it is possible short circuit due to installation errors. Disturbances in this system becomes a possibility of being harmful to humans, because the electric current can make men swoon even death. So that people can avoid the danger that occurs, then the system installation households should be connected to the ground through a prisoner whose price is relatively low. Of the prisoners is to be investigated in the installation of existing homes in the city of Medan.
"
Universitas HKBP Nonmensen, 2017
050 VISI 25:2 (2017)
Artikel Jurnal  Universitas Indonesia Library
cover
Rynaldo
"Microwave Link System adalah salah satu sistem komunikasi yang menggunakan gelombang radio sebagai medium menyampaikan data dari satu titik ke titik lain nya. Umum nya, untuk mendapatkan jangakauan jarak yang jauh, antenna dari Microwave Link dipasang di tempat yang lebih tinggi menggunakan tower. Hal ini membuat antena rawan akan gangguan petir terutama dalam keadaan cuaca hujan. Seringkali terdengar bahwa banyak terjadi kerusakan alat elektronik akibat adanya petir. Salah satu yang menjadi penyebabnya adalah grounding system yang tidak baik.
Tower telekomunikasi tidak lepas dari potensi permasalahan ini. Sistem proteksi petir adalah alat yang paling utama dalam menghadapi petir, dimana petir akan dialirkan ke tanah dari beberapa titik proteksi. Selain ini, grounding system juga harus diperhatikan terhadap peralatan elektronik baik di tower maupun di dalam Gedung, termasuk untuk Sistem Microwave Link.
Permasalah grounding yang buruk terjadi di salah satu tower telekomunikasi di Handil Kalimantan Timur, yang menyebabkan adanya kerusakan rusaknya beberapa perangkat Microwave Link. Sehingga diperlukan upaya menyeluruh dalam perbaikan grounding system nya. Dalam pelaksanaan ditemukan bahwa buruk nya instalasi grounding serta kurang nya perawatan (maintenance) adalah penyebab utama. Perbaikan dimulai dengan survei terhadap keadaan yang ada (existing), dilanjutkan dengan rencana serta pelaksanaan perbaikan.

Microwave Link System is a communication system that uses radio waves as a medium to convey data from one point to another. In generally, to get a long-distance range, the antenna from the Microwave Link is installed at a higher place using a tower. It makes the antenna prone to lightning interference, especially in rainy conditions. It’s quite common shown in news that a lot of damage to electronic equipment due to lightning. One of the causes is a bad grounding system.
The telecommunication tower cannot be separated from this potential problem. Lightning protection system is the most important tool in dealing with lightning, where lightning will be grounded to the ground(earth) from several points of protection. In addition, the grounding system must also be considered for electronic equipment both in the tower and inside the building, including for the Microwave Link System.
A poor grounding problem occurred in one of the telecommunications towers in Handil, East Kalimantan, which caused damage to several Microwave Link devices. It’s needed to improve the grounding system in holistic manners. In the implementation, it was found that poor grounding installation and lack of maintenance were the main causes. Improvements begin with a survey of the existing conditions, followed by plans and implementation of improvements
"
Depok: Fakultas Teknik Universitas Indonesia, 2022
TA-pdf
UI - Tugas Akhir  Universitas Indonesia Library
cover
Sophie Dwiyanti
"ABSTRAK
Collaborative learning/CL sebagai suatu metode pengajaran alternatif, diyakini bisa
membawa perubahan bagi falsafah pengajaran tradisional yang masih dianut di
Indonesia saat ini. Ciri pengajaran tradisional yang bertumpu pada pusat otoritas guru
dalam kelas, banyak mengakibatkan situasi berharga yang bisa dipetik siswa di kelas,
menjadi begitu saja terlewatkan dan bahkan pada akhirnya hanya menjadikan siswa
bersikap pasif pada proses pembelajaran dirinya sendiri (Harris & Graham, 1994;
Hewitt & Scardamalia, 1995).
Metode CL dibangun melalui pendekatan belajar yang mendefinisikan belajar sebagai
proses konstruksi pengetahuan, penggunaan pengetahuan terdahulu dan selalu terkait
dengan situasi (Resnick, 1989), sehingga implikasinya adalah harus ada kegiatan aktif
dalam proses belajar. Dengan demikian dalam kelas CL guru diminta untuk berbagi
otoritas dengan siswa, saling memberikan pengalaman dan pengetahuan bersama
menetapkan pilihan tugas dan menyelesaikannya secara bersama (Tinzmann, dkk.,
1990)
Aktivitas kelas yang demikian, didominasi oleh keadaan saling berbagi, yang akan
berimplikasi pada penggunaan alat dan kegiatan bersama. Kenyataan ini hanya bisa
sampai pada tujuan yang ditetapkan hanya bila ada pemahaman bersama (shared
understanding) mengenai tugas (Traum, 1996). Tercapainya pemahaman bersama
dalam CL dapat terlihat dari mekanisme social grounding/ SG (Dillenbourg &
Schneider, 1993). SG adalah proses dimana dua orang yang berdiskusi berusaha
mengelaborasi keyakinan bersarna (mutual belief) bahwa salah satu rekan diskusinya
telah memahami apa yang disampaikan pembicara SG terlihat dalam setiap unit
percakapan dimana masing-masing pembicara secara terus menerus berkoordinasi
untuk tetap ?terhubung? dengan ini pembicaraan, dengan cara menunjukkan bukti-
bukti yang dapat memandu pembicara mengetahui bahwa lawan bicaranya telah
memahami ucapannya.

Dalam aktivitas CL, komunikasi yang terjadi adalah hasil aktivitas kolektif yang
memerlukan tindakan yang terkoordinasi. Oleh karena itu grounding menjadi penting
artinya untuk melihat bahwa tiap anggota tetap berada di jalur yang sama. Selain itu,
shared understanding ini adalah kondisi yang dibutuhkan agar aktivitas CL berjalan,
karena kita tidak mungkin berasumsi bahwa kelompok rnemang berkolaborasi, bila
setiap anggota tidak mengerti apa yang dikolaborasikan. Dari pemikiran ini, maka
peneliti ingin memperoleh gambaran bagaimana social grounding yang terjadi pada
sekelompok siswa yang berpartisipasi dalam kegiatan collaborative learning.
Grounding dalam percakapan dapat dilihat melalui model kontribusi yang
dikemukakan oleh Clark dan Schaefer (dalam Clark & Brennan, 1991). Dalam model
ini, setiap kalirnat dianalisa dengan melihat bukti-bukti grounding, seperti relevant
next turn, continued attention, gelengan kepala atau dari teknik yang digunakan,
seperti menunjuk sesuatu, memberikan deskripsi alternatif dan sebagainya. Analisis
yang dilakukan dari tiap kalimat yang ada, dikenal dengan analisis percakapan
(conversation analysis) yang dikemukakan Schegloff (1991).
Untuk melihat gambaran social grounding, maka satu kelompok (terdiri dari 5 orang
siswa) berdiskusi mengenai suatu tugas (materi AIDS), dan direkam secara audio-
video selama kegiatan berlangsung. Penelitian yang dilakukan selama 8 kali sesi
diskusi, menghasilkan 8 buah transkrip percakapan, dengan total kalimat/giliran
bicara sebanyak 6452 buah. Selain itu penelitian ini menunjukkan juga bahwa dalam
kelompok terjadi grounding dengan persentase yang cukup tinggi (88,8%). Hal ini
dikuatkan dengan bukti-bukti positif bahwa siswa memiliki pemahaman dengan isi
diskusi.
Beberapa saran bisa diberikan untuk penelitian ini, bila guru ingin menerapkan CL
dalam kegiatan belajarnya, maka ia harus memainkan peran sebagai mediator yang
terus memantau jalannya diskusi yang rnemastikan siswa tetap terkoordinasi. Saran
lain yang dapat diberikan antara lain perumusan tujuan yang lebih jelas, pengaturan
jadwal kegiatan yang lebih lama namun dalarn frekuensi 1 kali saja dalam seminggu.
Selain itu, penulisan transkrip harus lebih mengikuti kaidah penulisan yang baku, dan
perlu untuk menonton kembali rekaman video nntuk melihat kalimat-kalimat yang
tidak bisa diidentifikasi dan sekaligus untuk mernperkaya observasi."
1998
S2756
UI - Skripsi Membership  Universitas Indonesia Library
cover
Muhammad Rizky Haritsyafah
"Pembumian (grounding) listrik merupakan sebuah sistem pentanahan untuk menghilangkan perbedaan potensial pada suatu instalasi listrik, sehingga kebocoran tegangan atau arus dapat langsung dialirkan ke tanah. Sistem pentanahan disini diperlukan untuk melindungi bangunan dan peralatan dari aliran listrik akibat gangguan sambaran petir. Grounding juga bisa berfungsi untuk melindungi alat elektronik dari kebocoran arus listirk. Dikarenakan banyak fungsi sistem pentanahan(grounding), maka grounding merupakan suatu sistem yang sangat vital bagi suatu bangunan, dan instalasi suatu sistem pentanahan di suatu gedung sebaiknya perlu diperhatikan agar fungsi-fungsi dari grounding itu sendiri bisa digunakan secara optimal. Penelitian pengukuran sistem pentanahan ini dilakukan di gedung Departemen Teknik Elektro, Departemen Teknik Mesin, dan Departemen Arsitektur Universitas Indonesia. Tujuan dari penelitian ini adalah mengevaluasi kelayakan sistem grounding di gedung-gedung tersebut. Untuk mendapatkan hasil yang lebih akurat maka penulis melakukan pengukuran sebanyak 3 kali. Dalam penelitian ini meninjau berbagai elemen seperti struktur tanah, kondisi tanah, serta kondisi lingkungan. Hasil yang didapat dari pengukuran dengan menggunakan earth tester yakni ketujuh objek yang diukur nilai pentanahannya sudah sesuai dengan standar PUIL 2000 yakni sebesar 5 Ω, dilihat dari hasil pengukuran nilai pentanahan di gedung Departemen Teknik Elektro, Departemen Teknik Mesin, serta Departemen Arsitektur ini maka bisa dikatakan “baik dan optimal’’ untuk sebuah sistem grounding. Setelah melakukan penelitian ini, maka penulis bisa menyimpulkan bahwa ketujuh objek yang diteliti sudah sesuai dengan standar PUIL 2000 dan instalasi pentanahannya masih cukup optimal.

Electrical grounding is a grounding system to eliminate potential differences in an electrical installation, so that voltage or current leakage can be directly channeled to the ground. The grounding system here is needed to protect buildings and equipment from electricity due to lightning strikes. Grounding can also serve to protect electronic devices from leakage current. Due to the many functions of the grounding system, grounding is a very vital system for a building, and the installation of a grounding system in a building should be considered so that the functions of the grounding itself can be used optimally. This grounding system measurement research was conducted in the building of the Department of Electrical Engineering, Department of Mechanical Engineering, and Department of Architectural, University of Indonesia. The purpose of this research is to evaluate the feasibility of the grounding system in these buildings. To get more accurate results, the author took measurements 3 times. This study reviewed various elements such as soil structure, soil conditions, and environmental conditions. The results obtained from measurements using an earth tester are that the seven objects measured grounding value is in accordance with PUIL 2000 standards of 5 Ω, seen from the measurement results of the grounding value in the building of the Department of Electrical Engineering, Department of Mechanical Engineering, and Department of Architecture, it can be said "good and optimal" for a grounding system. After conducting this research, the author can conclude that the seven objects studied are in accordance with the PUIL 2000 standard and the grounding installation is still quite optimal."
Depok: Fakultas Teknik Universitas Indonesia, 2023
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Ginting, Jefanya
"Sistem informasi pada suatu industri sangat dibutuhkan kehandalannya untuk menjaga keberlangsungan proses bisnis perusahaan itu. Untuk proses informasi tersebut menggunakan alat-alat elektronik yang bekerja pada range millivolt. Karenanya dibutuhan pengaman gedung beserta peralatan terutama peralatan elektronik yang bekerja dalam range milivolt dari efek sambaran petir yang bekerja dalam range kilovolt sangatlah penting.
Sistem informasi pada industri PT. X yang berlokasi di Kawasan Industri MM2100 Cibitung ? Bekasi Jawa Barat dalam kurun waktu 5 tahun terakhir mengalami gangguan kerusakan peralatan elektronik akibat sambaran petir. Penangkal petir dan sistem proteksi berupa sistem pentanahan kurang memadai untuk melindungi peralatan elektronik dari bahaya sambaran petir.
Berdasarkan data, hasil pengukuran dan perhitungan kondisi aktual maka ditemukan tegangan langkah dan resitansi tanah yang melebihi dari nilai standar.

Information systems on an industry badly needed to maintain the continuity of the process of establishment of business company. To process such information using electronic tools which work in the millivolt range. Hence the need for building safety and equipment mainly electronic equipment that works in a range from the effects of lightning milivolt who worked in the kilovolt range is important.
Information system on industrial PT. X located in an industrial area MM2100 Cibitung - Bekasi in West Java in a span of 5 years experience in electronic equipment damage due to lightning strikes. Lightning rods and grounding protection system of the system is less adequate to protect electronic equipment from the danger of lightning strikes.
Based on data, measurement and calculation of results and the actual condition of the voltage step and then discovered resistance land in excess of the value of the standard.
"
Depok: Fakultas Teknik Universitas Indonesia, 2012
S1386
UI - Skripsi Open  Universitas Indonesia Library
cover
Kezia Sherlita
"Perlindungan pada sistem tenaga listrik harus dirancang untuk memenuhi prinsip kehandalan, selektivitas, dan prinsip kestabilan, yang dapat dicapai melalui zonasi dan koordinasi proteksi. Dalam hal deteksi dan koordinasi proteksi gangguan tanah, sistem harus mempertimbangkan alokasi pentanahan dan kesesuaian hubungan, seperti pentanahan solid atau impedansi. Oleh karena itu, pemilihan lokasi dan koneksi pentanahan yang tidak tepat dapat menyebabkan gangguan yang tidak diinginkan dan kegagalan yang bertingkat. Studi ini menyajikan desain korektif untuk deteksi dan koordinasi proteksi gangguan hubung singkat satu fasa ke tanah. Sistem pentanahan dievaluasi dengan menggunakan rangkaian urutan nol untuk memperkirakan gangguan yang dapat terjadi pada sistem. Implementasi dari Standar IEEE 142-2007 digunakan untuk menyediakan sistem yang terhubung secara efektif, yang menghasilkan lokasi dan koneksi yang sesuai untuk pentanahan. Simulasi dilakukan dengan menggunakan perangkat lunak analisis sistem tenaga untuk membandingkan kinerja sebelum dan setelah desain korektif yang diusulkan. Hasilnya menunjukkan bahwa desain yang diusulkan dapat mengoreksi kesalahan operasi proteksi kesalahan tanah.

Power system protection must be designed to meet the reliability, selectivity, and stability principle, which can be achieved through zoning and coordination. In the case of ground fault protection detection and coordination, the appropriate grounding allocation and connection, i.e. solid or impedance, shall be considered throughout the system. Hence, inaccurate selection for grounding location and connection may lead to undesirable disturbances and cascaded failure. This paper presents a corrective design for ground fault protection detection and coordination in an actual 34.5 kV power system network which has faced several misoperation of the ground fault protection. For this, the system’s grounding is assessed by using zero sequence network and the issues are summarized. The implementation of IEEE 142-2007 Standard is utilized to provide an effectively grounded system, resulting in the suitable location and connection for the grounding. The simulation is carried out by using power system analysis software to compare the performances before and after the proposed corrective design. The results shows that the proposed design can solve the misoperation of the ground fault protection."
Depok: Fakultas Teknik Universitas Indonesia, 2024
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Hartadhi
"Gangguan adalah kenyataan yang tidak dapat dihindari pada sistem transmisi dan distribusi listrik. Gangguan yang paling sering terjadi adalah gangguan tanah, baik itu satu fasa maupun dua fasa ke tanah yang disebabkan fenomena alam sepeti pohon dan petir. Gangguan ini biasanya bersifat sementara sehingga akan sangat merugikan kalau terjadi pemutusan suplai daya pada beban yang bertujuan mengisolasi gangguan. Sistem pentanahan peralihan bekerja dengan memutuskan hubungan netral transformator ke tanah selama satu atau dua detik selama terjadi gangguan. Sistem ini akan bekerja sebagai proteksi tingkat pertama pada gangguan tanah yang bersifat sementara sehingga pemutusan suplai daya tidak perlu dilakukan.

Faults in transmission system are inevitably exist. Faults that occur are mostly ground fault, either one phase or two phase to ground. This type of fault is usually temporary due to natural phenomenons such as trees and lightnings. It would be so inefficient to disconnect the load from the power source just in order to isolate the fault. Ground Fault Path Clearance (GFPC) system will disconnect the connection between the transformator neutral and ground for one or two second(s) during the fault occurence. This system will be the preliminary protection against ground fault so it would not be necessary to disconnect the load from the power source."
Depok: Fakultas Teknik Universitas Indonesia, 2009
S51390
UI - Skripsi Open  Universitas Indonesia Library
cover
"This book covers the basic scientific theory and related application technologies of the pantograph-catenary system, including research findings on pantograph/catenary contact resistance, pantograph interface thermal effect, laws and characteristics of current-carrying friction and wear, the main research methods for pantograph arcs, the effects of arcs on pantograph systems and onboard equipment, and the materials used for pantographs and contact wires. Given its scope, it offers a valuable resource for students, scholars, and development engineers alike.
The relationship between pantograph and catenary is one of the three core aspects of the safe operation of high-speed electrified railways. The pantograph system provides electric power for the high-speed train through the sliding electric contact. As the trains operating speed increases, the pantograph system enters a state of prolonged sliding/vibration, resulting in frequent arcs, electrode erosion, and increased wear."
Singapore: Springer Nature, 2019
e20509618
eBooks  Universitas Indonesia Library