Annisa Dwinda Fildzah Hani
Abstrak :
Penelitian ini bertujuan untuk mendapatkan kombinasi parameter eksposi optimum pada pemeriksaan sinar-x diagnostik menggunakan Computed Radiography (CR). Kombinasi faktor eksposi yang diuji berada dalam rentang 55 kVp-66 kVp dan 15 mAs-24 mAs untuk toraks, 81 kVp-102 kVp dan 8 mAs-20 mAs untuk abdomen, serta filter tambahan 0 mmAl, 1 mm Al + 0.1 mm Cu, 1 mm Al + 0.2 mm Cu, dan 2 mm Al. Figure of Merit (FOM) sebagai rasio antara kuadrat Signal Difference to Noise Ratio (SDNR) dan dosis dipilih sebagai parameter uji, dengan parameter kualitas citra tambahan berupa Modulation Transfer Function (MTF) dan Contrast Consistency (CV). Meskipun didapatkan kombinasi dengan FOM tertinggi, hasil penelitian menunjukkan bahwa FOM tidak dapat digunakan sebagai parameter optimisasi tunggal dan penggunaannya harus disertai parameter lain. Karenanya, diperlukan penelitian lanjutan sebelum metode ini dapat diterapkan secara klinis. ......This study aims to obtain an optimum combination of exposure parameters on diagnostic x-ray examinations using Computed Radiography (CR). The combination of exposure parameters tested were in the range of 55 kVp-66 kVp and 15 mAs-24 mAs for thorax, 81 kVp-102 kVp and 8 mAs-20 mAs for the abdomen, and additional filters 0 mmAl, 1 mm Al + 0.1 mm Cu, 1 mm Al + 0.2 mm Cu, and 2 mm Al. Figure of Merit (FOM) as a ratio between the squared Difference to Noise Ratio (SDNR) signal and the Entrance Surface Dose (ESD) was chosen as optimization parameter alongside with additional image quality parameters such as Modulation Transfer Function (MTF) and Contrast Consistency (CV). Although the combination with the highest FOM was obtained, the results showed that FOM cannot be used as a single optimization parameter and its use must be accompanied by other parameters. Therefore, further research is needed before this method can be applied clinically.
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Asep Taopik
Abstrak :
Penelitian ini mengevaluasi pengaruh Teknik Automatic Tube Current Modulation dengan variasi pitch dan diameter efektif terhadap estimasi nilai dosis dan tingkat noise untuk pemeriksaan Abdomen pada pesawat CT Scan menggunakan in-house phantom yang merepresentasikan organ Abdomen. Pemindaian dilakukan pada objek in-house phantom menggunakan CT Scan Ingenuity 128 Philips dengan parameter eksposi tegangan tabung 120 kVp, variasi Dose Right Index (DRI) 10-14, serta variasi pitch 0,6; 0,8; 1,0; 1,2; dan 1,49. Hasil penelitian menunjukkan DDRI terverifikasi sekitar 10% sampai 13%, kecuali DRI 10 sampai 11 yang relatif tinggi yaitu rata- rata 15% sampai 17%. Nilai CTDIvol bergantung pada DRI atau arus tabung. Peningkatan DRI meningkatkan CTDIvol. Modulasi mAs pada akuisisi gabungan phantom terjadi pada ukuran phantom yang lebih kecil dengan tetap menjaga kestabilan noise. Noise terendah pada penerapan ATCM dihasilkan pada DRI 14. Penerapan ATCM pada objek in-house phantom pada pemeriksaan CT Scan protokol Abdomen berpengaruh terhadap perubahan nilai mAs, CTDIvol, dan noise. Spesifikasi ATCM pesawat CT Ingenuity 128 sesuai dengan ketentuan Philips. ......This study evaluates the effect of the Automatic Tube Current Modulation technique on pitch and effective diameter variation on the estimated dose value and noise level for abdominal examination on CT Scan machine using an in-house Phantom to represent abdominal region. Scanning use an Ingenuity 128 Philips CT Scan with parameters namely tube voltage 120 kVp, varied Dose Right Index (DRI) of 10-14, as well as under pitch variations of 0.6; 0.8; 1.0; 1.2; and 1.49. The changes in mAs, CTDIvol, and noise to the Philips reference value were then verified. ΔDRI is verified to be approximately 10% to 13%, except for DRI 10 to 11 which is relatifly high on average 15% to 17%. The CTDIvol value does depend on the DRI or tube current. An increase in DRI increases the CTDIvol. mAs modulation in combined phantom acquisition occurs at smaller phantom sizes while maintaining noise stability. The lowest noise in the application of ATCM is produced in the DRI 14. The application of ATCM to in-house phantom objects in the abdominal protocol CT Scan examination affects the change in mAs, CTDIvol, and noise values. The ATCM specifications of the Ingenuity 128 CT machine according to Philips regulations.
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2023
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Ade Riski Setiadi
Abstrak :
Mendapatkan citra kualitas tinggi dengan dosis pasien yang rendah merupakan suatu tujuan sekaligus tantangan dalam pemeriksaan radiologi diagnostik. Penelitian ini dilakukan menggunakan fantom in house yang dibuat dan didesain berdasarkan pengukuran ketebalan 116 pasien anak usia 0-15 tahun sebagai acuan ketebalan toraks, abdomen dan kepala. Citra fantom diambil dari berbagai faktor ekposi dalam rentang 45-60 kVp dan 4-12.5 mAs untuk toraks, 50-81 kVp dan 8-25 mAs untuk abdomen, serta 44-60 kVp dan 7.1-16 mAs untuk kepala. Optimasi ditentukan dengan menggunakan parameter figure of merit FOM yang merupakan rasio antara kuadrat dari signal-to-noise rasio SNR dengan dosis permukaan kulit ESD. Hasilnya diperoleh kondisi eksposi optimum pada fantom toraks sebesar 45-56 kVp dengan 4-5 mAs untuk anak usia 0-5 tahun, 45-60 kVp dengan 5-6.3 mAs untuk anak usia 5-10 tahun dan 45-60 kVp dengan 6.3-8 mAs untuk usia 10-15 tahun. Untuk fantom abdomen diperoleh kondisi optimum sebesar 50-53 kVp dengan 8 mAs untuk 0-3 tahun, 60-66 kVp dengan 12.5-16 mAs untuk usia 3-5 tahun, dan 63-70 kVp dengan 12.5-16 mAs untuk usia 5-15 tahun. Hasil optimasi untuk fantom kepala diperoleh 47-50 kVp dengan 8 mAs untuk usia 0-5 tahun, 50-56 kVp dengan 8 mAs untuk usia 5-15 tahun. Disamping itu diperoleh juga nilai Backscatter Factor BSF untuk fantom toraks sebesar 1.274-1.435 pada rentang 45-60 kVp, abdomen sebesar 1.274-1.395 pada rentang 50-81 kVp, dan kepala sebesar 1.110-1.586 pada rentang 44-60 kVp. ......Obtaining high image quality with low dose i.e. optimization remains a challenge in the practice of diagnostic radiology procedures, especially in pediatric cases. This research was carried out as an attempt to address the issue using an in house phantom designed based on the geometry in terms of thoracic, abdomen and cranial thickness of 116 pediatric patients 0 to 15 years . Images of the phantom were obtained from varied factors of tube potentials ranging from 45 60 kVp with 4 12.5 mAs for thoracic, 50 81 kVp with 8 25 mAs for abdomen, and 44 60 kVp with 7.1 16 mAs for cranial. Figure of Merit FOM was employed as optimization parameter, being a ratio of squared signal to noise ratio SNR and entrance surface dose ESD calculated and measured, respectively, for each exposure. The result demonstrated that the optimum exposure parameter on thoracic phantom ranged from 45 56 kVp with 4 5 mAs 0 5 years, 45 60 kVp with 5 6.3 mAs 5 10 years, and 45 60 kVp with 6.3 8 mAs 10 15 years. For abdomen examination with grid, optimized parameters were at the ranges of 50 53 kVp with 8 mAs 0 3 years, 60 66 kVp with 12.5 16 mAs 3 5 years , and 63 70 kVp with 12.5 16 mAs 5 15 years. For cranial examinations, the optimum parameter combination was obtained at the ranges of 47 50 kVp with 8 mAs 0 5 years , and 63 70 kVp with 12.5 16 mAs 5 15 years. This work also obtained that the backscatter factors for thoracic phantom were 1.274 1.435 at 45 60 kVp, 1.274 1.395 at 50 81 kVp for abdomen phantom, and 1.110 1.586 at 44 60 kVp for cranial phantom.
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2017
T47944
UI - Tesis Membership  Universitas Indonesia Library
cover
Marwazi
Abstrak :
Computed Tomography (CT) merupakan modalitas sinar-X untuk membuat citra organ dalam tiga dimensi. Akuisisi citra dilakukan dengan perputaran tabung sinar-X yang disertai gerakan meja, sehingga tabung mengelilingi pasien dalam bentuk spiral. Gerakan meja pasien persatu rotasi gantry dibagi lebar kolimator pada isocenter dikenal dengan pitch, yang berpengaruh pada kualitas citra maupun dosis radiasi pada pasien. Telah diobservasi profil ditribusi dosis sepanjang sumbu-Z fantom simulasi toraks in house berbentuk silinder elips dengan ukuran 28 cm × 21 cm dan panjang 22 cm. Fantom terbuat dari bahan PMMA dengan Hounsfield Unit (123,10 ± 3,96 HU) dilengkapi dengan objek simulasi paru dari gabus patah (-790,60 ± 15,55 HU), dan tulang belakang dari material teflon dengan (918,60 ± 7,35) balok dan silinder untuk tempat film gafchromic ukuran 1 cm x 25 cm. Posisi film ditandai dengan 1-9 dengan koordinat berturut turut (0, 0), (5, 0), (10, 0), (-5, 0), (-10, 0), (0, 4), (0, 8), (0,-4), (0,-8). Citra fantom diakuisisi dengan kondisi eksposi 120 kV,100 mAs dan pitch 0,8, 1,0, dan 1,5. Dosis minimum terjadi pada awal dan akhir scan untuk seluruh profil dan nilai pitch, dosis rata-rata material paru (2, 3, 4, dan 5) dalam rentang (2,49-2,90) mGy untuk pitch 0,8 dan (2,36-2,88) mGy untuk pitch 1,0, serta (2,33-2,74) mGy untuk pitch 1,5, relatif lebih rendah disbanding dengan pada jaringan lunak dan tulang. Dosis maksimum selalu terjadi di pertengahan sumbu-Z. Dapat disimpulkan bahwa penggunaan pitch 0,8 dan 1,0 tidak memberikan perbedaan dosis yang signifikan dan menurunkan dosis rata-rata pada pitch 1,5. Selain itu dosis maksimum tidak selalu terjadi di pertengahan sumb-z dikarenakan oleh material isotropis.
Computed Tomography (CT) is an X-ray modality for scanning organ in three dimensional images. Image acquisition is performed by rotating X-ray tube that match with table movements, there by the tube can cover patient body in a spiral scan. Patient table movements by gantry rotation divided by the width of the collimator on the isocenter is known as a pitch, which affects the image quality and radiation dose in the patient. A dose distribution profile has been observed along the z-axis of the in-house thorax phantom simulation in an elliptical cylinder form with the size of 28 cm x 21 cm and 22 cm length. Phantom is made from PMMA with Hounsfield Unit (123.10 ± 3.96 HU) was equipped with a lungs simulation object using a cork (-790.60 ± 15.55 HU), a spine using Teflon material (918.6 ± 7.35 HU), and 9 bar and a cylinder to place 1 cm x 25 cm gafchromic films. The position of the film was marked with point position 1-9 for the series of coordinates (0,0), (5, 0), (10, 0), (-5, 0), (-10, 0), (0, 4), (0, 8), (0,-4), (0, -8) cm. The phantom images was performed with an exposure condition by 120 kV, 100 mAs and pitch variations (0.8, 1.0 and 1.5). The minimum dose occured at the beginning and end of the scan for all profiles and pitch values. The average dose of lung material (2, 3, 4, and 5) in the range (2.49-2.90) mGy for pitch 0.8, (2.36-2.88) mGy for pitch 1.0 and (2.33-2.74) mGy for pitch 1.5. The dose in lung was relatively lower compared to the dose in soft tissue and bone. The maximum dose always occur in the middle of the z-axis. It can be concluded that the use of pitch 0.8 and 1.0 did not provide a significant dose difference and reduced the average dose on pitch 1.5. Moreover, the maximum dose does not always occur in the middle of the z-axis due to an isotropic material.
Depok: Universitas Indonesia, 2020
T55322
UI - Tesis Membership  Universitas Indonesia Library
cover
Khairul Mar`ie
Abstrak :
Computed Tomography (CT) Scanner merupakan modalitas pencitraan tubuh tiga dimensi. Untuk observasi organ tubuh yang bergerak, selain menggunakan Singlesource CT (SSCT) telah dikembangkan pula Dual-source CT (DSCT) yang dilengkapi dengan sumber sinar-X primer dan sekunder. Posisi kedua sumber DSCT membentuk sudut 90°, dan pada saat akuisisi citra keduanya berputar 90°. Dengan demikian proses akuisisi citra organ tubuh yang bergerak dapat dilaksanakan dalam waktu yang relative singkat. Berbagai pengujian untuk menganalisis kualitas citra biasanya dilakukan menggunakan fantom. Berbagai macam jenis fantom yang telah dibuat dengan menggunakan material ekuivalen jaringan telah banyak dikembangkan. Dalam meningkatkan studi fantom untuk menganalisa kualitas citra CT scan yang meliputi pengukuran detectability, noise, dan resolusi spasial pada penelitian ini dilakukan suatu konstruksi dan pengembangan fantom desain khusus (in-house) yang terdiri dari beberapa material ekuivalen jaringan. Fantom terdiri dari 3 bagian. Fantom in-house yang dibuat digunakan untuk analisis kualitas citra dan dikhususkan untuk QC pada DSCT dan SSCT. Fantom in-house yang di buat telah dilakukan uji coba dan dapat digunakan untuk evaluasi kualitas citra dari DSCT dan SSCT. Hasil pengukuran detektabilitas, menunjukkan DSCT mampu mendeteksi objek dengan kontras rendah pada objek pipa silinder berukuran 2 mm. Pengukuran SNR pada citra SSCT didapatkan terjadinya peningkatan nilai SNR seiring dengan pertambahan mAs, dan nilai SNR objek pada bagian perifer tidak selalu sama daripada center dikarenakan proses scanning helical. Pengukuran resolusi spasial menunjukkan nilai MTF 10% dari DSCT lebih rendah di bandingkan dengan dengan SSCT. Perbedaan mAs yang digunakan tidak berpengaruh terhadap MTF 10% yang dihasilkan. ...... Computed Tomography (CT) Scanner is a three-dimensional body imaging modality. Instead of using Single-Source CT (SSCT), the observation of moving organs could be performed also by Dual-Source CT (DSCT) that has been developed recently. DSCT is equipped with primary and secondary x-ray sources. The position of the two sources DSCT forms an angle of 90°, and at the time of image acquisition, both rotate 90°. This new technology of CT could reduce the scan time so that the process of image acquisition of a moving body can be carried out in a relatively short time. A special phantom would be needed to perform several testing procedures for analyzing the image quality. Many phantom modules were designed with tissue-equivalent materials. The proposed in-house phantom was aimed to enhance the phantom study in order to analyze the CT scan image quality: detectability, noise and spatial resolution. The phantom was special designed and constructed with several tissue-equivalent materials. The phantom was consist of three part modules. This in-house phantom can be used for image quality analyzis for both quality control (QC) of DSCT and SSCT. The in-house phantom was tested and image quality evaluation of DSCT and SSCT can be succesfully performed with the phantom. The detectability measurement shows that DSCT was able to detect the object with low contrast in cylidrical pipe object with 2 mm diameter. The SNR measurement for noise test in SSCT image shows that the SNR tends to rise proportional to the mAs increment. The SNR value of the object in periferal region seems to be higher compared to the SNR value from the central region, due to the helical scanning process. The highest SNR value shows the lowest noise. The spatial resolution shows that 10% MTF value from DSCT is lower than SSCT. It means that SSCT represents the better spatial resolution compared to DSCT. The mAs difference during this work was not affect the 10% MTF value produced.
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2020
T55298
UI - Tesis Membership  Universitas Indonesia Library
cover
Irfan Nur Fathur Rahman
Abstrak :
Pada penelitian ini, telah dilakukan studi karakter pada CR AGFA 85-X dalam hal sensitivitas detektor dan kualitas citra sekaligus untuk mendeskripsikan rekomendasi penggunan fantom in-house yang dibuat khusus untuk studi ini. Uji karakter sensitivitas detektor dilakukan dengan memetakan korelasi antara nilai piksel dan dosis pada reseptor citra, sedangkan evaluasi kualitas citra dilakukan berdasarkan nilai SDNR dari masing-masing obyek pada fantom in-house. Hasil dari evaluasi citra direpresentasikan dengan koefisien variasi (CV), koefisien linearitas (CL), dan Modulation Transfer Function (MTF). CV merupakan nilai yang menunjukkan konsistensi kontras terhadap perubahan ukuran obyek, sedangkan CL merepresentasikan linearitas perubahan kontras terhadap perubahan kedalaman obyek. Sementara itu, MTF sebagai ukuran resolusi spasial dievaluasi dengan menggunakan metode slanted edge dengan menggunakan lempengan tembaga pada fantom in-house. Hasil uji sensitivitas detektor memperlihatkan korelasi logaritmik terbalik antara nilai piksel dengan dosis reseptor dengan persamaan y=-18.5ln(x) + 79.655dengan nilai R2=0.9642. Fantom in-house yang telah dibuat direkomendasikan untuk digunakan pada 70 kVp atau 75 kVp pada representasi anatomi abdomen, 110 kVp atau 115 kVp untuk mensimulasikan pemeriksaan thorax dan 75 kVp atau 80 kVp pada simulasi pemeriksaan cranial. ......In this research, the characters of AGFA CR 85-X in terms of detector sensitivity and image quality has been performed. The study was carried out also to provide recommendations on the use of in-house phantom specifically constructed for this study. Detector sensitivity was characterized by plotting the correlation between pixel value and dose on image receptor, while image quality evaluation was performed based on the Signal Difference Noise Ratio (SDNR) values of each object at the in-house phantom. Resulting image quality were represented by coefficient of variance (CV), coefficient of linearity (CL), and Modulation Transfer Function (MTF). CV represent the consistency of contrast (SDNR) with the change of object size, while CL reflect the linearity of contrast with the change of object depth. Meanwhile, MTF served as a measure of spatial resolution and was evaluated using the slanted edge method using copper plates at the in-house phantom. The detector sensitivity test results shown inverse logarithmic correlation between pixel values ​​and receptor doses with the equation y = -18.5ln (x) + 79,655 with the value of R2 = 0.9642. The constructed in-house phantom was recommended to be used at 70 kVp or 75 kVp when representing the abdominal anatomy, 110 kVp or 115 kVp for thorax examination and 75 kVp or 80 kVp in cranial examination simulation.
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2019
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Nurul Aini
Abstrak :
Pada penelitian ini telah dilakukan studi karakter fantom pada sistem computed radiography (CR) Fuji dalam beberapa parameter kualitas citra yang direpresentasikan dalam evaluasi koefisien linearitas (CL), koefisien variasi (CV), dan modulation transfer function (MTF). Penelitian ini menggunakan tiga fantom yang berbeda sebagai pembanding dengan representasi tubuh abdomen. Koefisien linearitas merupakan nilai yang menunjukkan linearitas perubahan kontras terhadap perubahan kedalaman objek, sedangkan koefisien variasi menunjukkan nilai konsistensi kontras terhadap perubahan ukuran objek. Hasil MTF menunjukkan resolusi spasial yang dievaluasi menggunakan metode slanted edge dengan menggunakan lempengan tembaga yang terdapat pada in-house phantom Hasil yang diperoleh dari penelitian ini adalah pada fantom in-house nilai yang direkomendasikan adalah 75 kV dengan filter 1 mm Al + 0.1 mm Cu untuk linearitas kontras, 65 kV dengan filter 2 mmAl untuk konsistensi kontras, dan 70 kV dengan filter 1 mm Al + 0.2 mm Cu untuk MTF. Sedangkan untuk fantom in-house diperoleh nilai 60 kV dengan filter 1 mm Al + 0.2 mm Cu untuk linearitas kontras dan 60 kV dengan filter 0 mm Al untuk konsistensi kontras. ......This study was performed to characterize in-house phantoms on computed radiography (CR) systems in terms of image quality parameters that represented coefficient of linearity (CL), coefficient of variation (CV), and modulation transfer function (MTF). This study used three different phantoms as a comparison, combined with abdominal anatomy representation. The CL is a value that shows the changes of contrast linearity to the changes of object depth, while the coefficient of variation shows the value of contrast consistency to changes of object size. MTF showed the spatial resolution that evaluated using the slanted edge method using copper slabs in the in-house phantoms. The results obtained from this study are that in-house phantom 1.0 is recommended to be used at 75 kV with filters 1 mm Al + 0.1 mm Cu for contrast linearity, 65 kV with 2 mmAl filters for contrast consistency and 70 kV with 1 mm Al filter + 0.2 mm Cu for MTF. As for the in-house phantom 2.0 the recommended conditions are 60 kV value with a filter of 1 mm Al + 0.2 mm Cu for contrast linearity and 60 kV with a 0 mm Al filter for contrast consistency.
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2019
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Ika Hariyati
Abstrak :
Akuisisi citra sistem digital perlu dioptimasi untuk mendapatkan kombinasi parameter fisis paling optimum, sehingga menghasilkan kualitas citra yang cukup dengan dosis radiasi atau mengikuti prinsip ALARA (as low as reasonably achievable). Studi ini dilakukan pada dua anatomi yaitu thoraks dan abdomen dengan fantom in-house yang dibuat khusus sebagai alat kuantisasi kualitas citra. Parameter Figure of Merit (FOM) dikalkulasi sebagai perbandingan antara SDNR kuadrat dan dosis yang aplikasinya diuji pada studi ini. Parameter kualitas citra lainnya direpresentasikan oleh Modulation Transfer Function (MTF) dan Contrast Consistency (CV). Pada pengukuran menggunakan fantom In-house menghasilkan nilai FOM tertinggi pada thoraks ketika kombinasi faktor eksposi di 57 kV, 8 mAs, 1 mm Al + 0.1 mm Cu; 55 kV, 6.3 mAs, 1 mm Al +0.1 mm Cu dan 63 kV, 5 mAs, 1 mm Al +0.1 mm Cu untuk ketebalan 15 cm, 20 cm, dan 24 cm. Pada abdomen, kombinasi faktor eksposi di 102 kV, 12.5 mAs; 96 kV, 12.5 mAs; 81 kV, 8 mAs, dengan 1 mm Al +0.2 mm Cu menghasilkan nilai FOM tertinggi untuk ketebalan 20 cm, 25 cm, dan 30 cm. Studi ini menunjukkan perlunya penelitian lanjutan untuk mendeskripsikan parameter lain untuk keperluan optimasi. ......Digital image acquisition system needs to be optimized to get the most optimum combination of physical parameters, to produce sufficient image quality with radiation doses following ALARA (as low as reasonably achievable) principles. This study was carried out on two anatomies, namely thorax and abdomen with in-house phantoms specifically constructed as image quality quantization tool. The Figure of Merit (FOM) parameter is calculated as the ratio between squared Signal Different to Noise Ratio (SDNR) and the dose for which the application was tested in this study. Other image quality parameters are represented by Modulation Transfer Function (MTF) and Contrast Consistency (CV). The measurements using the in-house phantom produced the highest FOM values ​​on the thorax when the combination of exposure factors at 57 kV, 8 mAs, 1 mm Al + 0.1 mm Cu; 55 kV, 6.3 mAs, 1 mm Al + 0.1 mm Cu and 63 kV, 5 mAs, 1 mm Al + 0.1 mm Cu for thicknesses of 15 cm, 20 cm, and 24 cm. On the abdomen, a combination of exposure factors at 102 kV, 12.5 mAs; 96 kV, 12.5 mAs; 81 kV, 8 mAs, with 1 mm Al +0.2 mm Cu was resulting in the highest FOM value for 20 cm, 25 cm, and 30 cm thickness. This study shows the need for further research to describe other parameters for optimization purposes.
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2019
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Intan Apriliani Syaridatul Mu`minah
Abstrak :
Pengecekan akurasi kualitas citra dalam program kontrol kualitas quality control, QC dapat ditingkatkan dengan penggunaan fantom yang mendekati kondisi realistis pada pemindaian klinis. Penelitian ini ditujukan untuk mengembangkan fantom desain khusus yang terdiri dari material organik ekuivalen-hati dan otot jaringan lunak . Karakterisasi sifat radiologi material ekuivalen jaringan menunjukan bahwa material ekuivalen jaringan lunak otot yang tersusun atas campuran Gondorukem, Malam Cecek, dan tepung beras dengan rasio massa 70/20/10 memiliki CT Number -20.27 0.33 HU, densitas massa 1.055 g/cm3 dan densitas elektron 3.461 1023 e/m3. Material ekuivalen jaringan hati yang tersusun atas campuran Malam Cecek dan tepung beras dengan rasio massa 60/40 memiliki CT Number 74.17 1.48 HU, densitas massa 1.024 g/cm3 dan densitas elektron 3.396 1023 e/m3. Penggunaan fantom desain khusus dalam mengevaluasi kualitas citra PET berdasarkan parameter full-width-half-maximum FWHM resolusi dan signal-to-noise ratio SNR menunjukan bahwa detektabilitas sistem pemindaian PET bergantung terhadap ukuran pixel dan metode rekonstruksi citra yang digunakan. Sistem pencitraan PET/CT Siemens Biograph dengan rekonstruksi True-X dan filter Butterworth menggunakan ukuran pixel 1 x 1 mm2, memberikan ukuran obyek pada citra PET lebih kecil daripada ukuran obyek sebenarnya, kecuali pada obyek 4.02 mm. Sistem pemindaian PET/CT Philips Gemini TOF 16 dengan ukuran pixel 4 x 4 mm2 menunjukan adanya perbesaran ukuran obyek kecil dengan diameter kurang dari 16 mm. Kedua pesawat PET/CT menunjukan bahwa ukuran obyek pada citra cenderung lebih kecil atau mencapai threshold 80 dari ukuran sebenarnya pada obyek berdiameter lebih besar sama dengan 16.30 mm. Sebaliknya, overestimation nilai FWHM terjadi pada obyek berukuran kecil 4.20 mm sebagai akibat dari terjadinya partial volume effect. Studi pengukuran kualitas citra dengan fantom desain khusus ini menunjukan bahwa pemilihan metode rekonstruksi, filter post processing, dan ukuran pixel mempengaruhi resolusi atau detektabilitas dan SNR pada citra PET. Pada akhirnya, fantom desain khusus ini mampu memberikan analisa kualitas.
The purpose of this research was to develop a phantom for quality control QC of PET CT image quality. The phantom was constructed by tissue equivalent materials which consist six cylindrical hot lesions with diameter of 4.20, 6.20, 8.30, 9,80, 16.30, and 19.00 mm. Wax and rice starch were combined to produce the tissue equivalent materials. The results showed that combination 70 20 10 of gondorukem cecek wax rice starch and 60 40 of cecek wax rice starch yielded liver and muscle surrogate materials respectively. Liver equivalent material LEM was 74.17 1.48 HU, 1.024 g cm3 of mass density, and 3.396 1023 e m3 of electron density. While, muscle equivalent material MEM was 20.27 0.33 HU, 1.055 g cm3 of mass density and 3.461 1023 e m3 of electron density. Then, the phantom was scanned using two different PET CT scanner to determine the detectability and signal to noise ratio SNR as measure PET CT imaging performance. It showed that the detectability of PET CT scanner was affected by pixel size and reconstruction method for image acquisitions. For Siemens Biograph PET CT scanned using pixel sixe of 1 1 mm2, FWHMs were smaller than the actual size of the hot lesions. Meanwhile, for Philips Gemini PET CT scanned using pixel sixe of 4 4 mm2, FWHMs were larger than the actual size of the hot lesions. For both PET CT scanner, ratio of FWHM actual size reached the threshold of 80 at object diameter ge 16.30 mm. In contrast, overestimation of FWHM occurred at smaller object diameter 4.20 mm significantly caused by the partial volume effect. The study also indicated that image reconstructions, post processing smoothing filter, and pixel size may give impact to the detectability and SNR performed by a PET CT system. It was concluded that the phantom could be used to analyze the image quality performance in PET CT imaging.
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2018
T50690
UI - Tesis Membership  Universitas Indonesia Library