Budiani Christina Natalia Metrana
"Latar Belakang: Kegunaan laringoskop video untuk intubasi endotrakeal telah terbukti bermanfaat pada tatalaksana jalan napas normal ataupun sulit. Namun harga laringoskop video seperti McGrath MAC® yang mahal menjadi hambatan. Sebagai alternatif, dapat digunakan kamera portabel yang dipasangkan pada bilah Macintosh, dihubungkan via wifi ke telepon genggam, untuk membantu visualisasi laring seperti halnya laringoskop video. Sampai saat ini belum ada penelitian yang membandingkan waktu intubasi endotrakeal menggunakan modifikasi laringoskop Macintosh dengan laringoskop video McGrath MAC® pada populasi dewasa.
Metode: Uji klinis acak tersamar tunggal terhadap 62 subjek penelitian untuk membandingkan waktu intubasi endotrakeal menggunakan modifikasi laringoskop Macintosh dengan laringoskop video McGrath MAC® pada populasi dewasa. Kriteria penolakan adalah sulit jalan napas, kehamilan, penyakit jantung iskemik akut, gagal jantung, blok jantung derajat 2 atau 3, sindrom Guillain Barre, myasthenia gravis.
Hasil: Median waktu intubasi A (waktu yang diukur saat laringoskop masuk melewati gigi sampai mendapatkan visualisasi glotis) menggunakan modifikasi Macintosh 18(6-65) detik dibandingkan McGrath MAC® 21(10-70) detik (p 0.652). Median waktu intubasi B (waktu yang diukur saat mendapatkan visualisasi glotis sampai ETT masuk ke dalam trakea) 39(20-101) detik dibandingkan 50(27-102) detik (p 0,003). Median waktu intubasi total 63 (27-114) detik dibandingkan 74 (40-133) detik (p 0,032). Selain itu juga dicatat angka keberhasilan intubasi pada upaya pertama menggunakan modifikasi laringoskop Macintosh 90,3%, angka visualisasi glotis skor POGO 100 67,7% dan skor POGO 75 29%, komplikasi takikardia dan laserasi mukosa jalan napas berupa abrasi ringan pada daerah orofaring. Secara keseluruhan, para pengguna modifikasi laringoskop Macintosh menganggap alat ini baik untuk digunakan, baik dari segi kemudahan insersi alat, kemudahan penggunaan alat, dan visualisasi glotis.
Simpulan: Intubasi endotrakeal menggunakan modifikasi laringoskop Macintosh membutuhkan waktu yang lebih singkat dibandingkan dengan menggunakan laringoskop video McGrath MAC® pada pasien dewasa.

Background: The use of video laryngoscope has been proven to be beneficial for endotracheal intubation for normal and difficult airway management. But the problem with using a video laryngoscope is often the price of the tools. A widely used video laryngoscope, such as McGrath MAC® is expensive. As an alternative to help visualize the larynx like a video laryngoscope, we can use a portable camera placed in a Macintosh blade, then connected via wifi to a mobile phone. However, there is no available research that compares intubation time using modified Macintosh laryngoscope vs McGrath MAC® video laryngoscope in the adult population.
Methods: This study is a single-blinded randomized clinical trial of 62 subjects to measure the intubation time using modified Macintosh laryngoscope compared with McGrath MAC® video laryngoscope in the adult population. Exclusion criteria are difficult airway, pregnancy, acute ischemic heart disease, second or third-degree heart block, Guillain Barre syndrome, myasthenia gravis.
Results: Median intubation time A (time taken since laryngoscope passes the teeth until glottic visualization) using modified Macintosh and McGrath MAC® were 18(6-65)s and 21(10-70)s (p 0.652), consecutively. Median intubation time B (time taken since glottic visualization until tube insertion into the trachea) was 39(20-101)s and 50(27-102)s (p 0,003). Median total intubation time was 63 (27-114)s using modified Macintosh, compared with 74 (40-133)s (p 0,032) using McGrath MAC®. Besides that, we also noted the first attempt success rate in modified Macintosh was 90,3%, glottic visualization with POGO score 100 was 67,7% and POGO score 75 was 29%. The complications found in this study were tachycardia and airway mucosal laceration such as mild oropharyngeal abrasion. In conclusion, modified Macintosh users decide that this equipment is convenient, in terms of insertion easiness, usefulness, and glottis visualization.
Conclusion: Endotracheal intubation using modified Macintosh laryngoscope takes a shorter time compared with McGrath MAC® video laryngoscope in the adult population
"
Jakarta: Fakultas Kedokteran Universitas Indonesia, 2020
SP-pdf
UI - Tugas Akhir  Universitas Indonesia Library
cover
Intan Anggun Pratiwi
"Latar Belakang: Pandemi COVID-19 telah menjadi tantangan besar bagi dunia kesehatan. Tenaga kesehatan merupakan populasi yang sangat rentan tertular dikarenakan tingginya intensitas dan frekuensi pajanan SARS-CoV-2. Risiko penularan meningkat apabila tenaga medis melakukan tindakan yang memicu aerosilisasi, salah satunya adalah intubasi endotrakeal karena tingginya viral load pada saluran napas. Sebanyak 3,2% pasien COVID-19 memerlukan tindakan intubasi endotrakeal dan ventilasi mekanis. Intubasi endotrakeal yang efektif pada pasien COVID-19 penting dilakukan untuk menurunkan mortalitas dan risiko penularan. Penelitian ini bertujuan intuk mengetahui faktor-faktor yang memengaruhi efektivitas intubasi endotrakeal pada pasien terkonfirmasi COVID- 19 di RSUP Persahabatan.
Metode: Penelitian ini merupakan penelitian observasional yang menggunakan desain potong lintang yang dilakukan di IGD, ICU Rasmin Rasjid dan ICU PINERE RSUP Persahabatan pada bulan Juni 2021 – Juni 2022. Subjek peneltian ini adalah pasien terkonfirmasi COVID-19 yang dilakukan tindakan intubasi endotrakeal yang memenuhi kriteria inklusi dan eksklusi. Tindakan intubasi endotrakeal dinilai dari observasi rekaman CCTV. Selanjutnya karakteristik subjek, karakteristik intubasi endotrakeal dan faktor-faktor yang memengaruhi intubasi endotrakeal dievaluasi.
Hasil: Pada penelitian ini didapatkan 59 subjek penelitian. Proporsi intubasi endotrakeal efektif pada pasien COVID-19 sebesar 20,34%. Median lama waktu tindakan intubasi endotrakeal adalah 38 (19-189) detik. Sebanyak 32 (54,24%) tindakan intubasi endotrakeal dilakukan oleh spesialis anestesi dan 27 (45,76%) oleh PPDS Pulmonologi dan Kedokteran Respirasi. Hasil analisis bivariat didapatkan hasil bermakna secara statistik pada variabel penyakit kardiovaskular+DM (OR 0,24 (IK 95% 0,06-0,91), p=0,028) dan variabel operator (OR 0,07 (IK 95% 0,01-0,62), p=0,004). Hasil analisis multivariat menunjukkan hasil bermakna secara statistik hanya pada variabel operator (adjusted OR 0,06 (IK 95% 0,01-0,60), p=0,016).
Kesimpulan: Terdapat hubungan penyakit kardiovaskular+DM dan operator terhadap intubasi endotrakeal efektif pada pasien COVID-19 di RSUP Persahabatan.

Background: The COVID-19 pandemic has become a major challenge for the healthcare system. Healthcare workers are vulnerable population of COVID-19 transmission due to high intensity and frequency of exposure to SARS-CoV-2. The risk of transmission increases in aerosolization procedure such as endotracheal intubation because of the high viral load in the airways. Approximately 3.2% of COVID-19 patients require endotracheal intubation and mechanical ventilation. Effective endotracheal intubation in COVID-19 patients is important parameter to reduce mortality and the risk of transmission to healthcare workers. This study aims to determine the factors that influence the effectiveness of endotracheal intubation in patients with COVID-19 in National Respiratory Center, Persahabatan Hospital.
Methods: This study is an observational study using a cross-sectional design which was carried out in the emergency department, ICU Rasmin Rasjid and ICU PINERE of National Respiratory Center, Persahabatan Hospital in June 2021 – June 2022. The subjects of this study were COVID-19 patients who underwent endotracheal intubation who met the criteria inclusion and exclusion. The endotracheal intubation procedure was assessed from the observation of CCTV recordings. The characteristics of the subject, the characteristics of endotracheal intubation and the factors that influence endotracheal intubation were evaluated.
Results: In this study, there were 59 subjects. The proportion of effective endotracheal intubation in COVID-19 patients was 20.34%. The median length of time for endotracheal intubation was 38 (19-189) seconds. Among the subjects, 32 (54.24%) endotracheal intubation were performed by anesthesiologists and 27 (45.76%) were performed by Pulmonology and Respiratory Medicine residents. The results of the bivariate analysis showed statistically significant results on the cardiovascular disease + DM comorbid (OR 0.24 (95% CI 0.06-0.91), p=0.028) and operator (OR 0.07 (95% CI 0.01-0.62), p=0.04). The results of the multivariate analysis showed statistically significant results only for operator (adjusted OR 0.06 (95% CI 0.01-0.60), p=0.016).
Conclusion: There is relationship of cardiovascular disease + DM comorbid and operator with effective endotracheal intubation in COVID-19 patients at National Respiratory Center, Persahabatan Hospital.
"
Jakarta: Fakultas Kedokteran Universitas Indonesia, 2023
SP-pdf
UI - Tugas Akhir  Universitas Indonesia Library
cover
Adriana Lukmasari
"Latar belakang: Intubasi endotrakeal merupakan tindakan yang cukup rumit dan memiliki risiko tinggi. Intubasi endotrakeal neonatus memiliki angka keberhasilan yang rendah pada percobaan pertama (first attempt) yaitu 20,3% dikarenakan kondisi desaturasi atau bradikardia. Angka mortalitas dan gangguan neurodevelopmetal meningkat pada neonatus yang gagal pada percobaan pertama intubasi. Penggunaan teknik HFN sebagai oksigenasi tambahan saat percobaan intubasi terbukti meningkatkan keberhasilan intubasi endotrakeal neonatus akan tetapi teknik tersebut memerlukan perangkat tambahan yang tidak selalu tersedia di fasilitas kesehatan. Teknik oksigenasi tambahan berupa VTP nasal dengan kanula RAM belum pernah diteliti.
Tujuan: Untuk mengetahui efikasi ventilasi tekanan positif nasal dengan kanula RAM terhadap keberhasilan intubasi endotrakeal bayi prematur.
Metode: Uji klinis terbuka yang dilaksanakan pada bulan Januari hingga Juni 2024. Sampel penelitian adalah bayi prematur usia gestasi ≥ 25 minggu sampai 34 minggu dengan asfiksia berat atau distres napas berat atau apnea yang memenuhi kriteria inklusi. Dilakukan randomisasi dan dibagi menjadi 2 kelompok yaitu kelompok kontrol (VTP standar) dan kelompok perlakuan (VTP standar yang ditambahkan VTP nasal dengan kanula RAM).
Hasil: Terdapat 78 sampel yang terdiri dari 39 kelompok perlakuan dan 39 kelompok kontrol. Keberhasilan intubasi pada kelompok perlakuan adalah 84,6% dibandingkan kelompok kontrol 41% dengan nilai Absolute Risk Reduction (ARR) 44% dan Number Need to Treat (NNT) 2. Kejadian desaturasi pada kelompok perlakuan adalah 10,3% dibandingkan kelompok kontrol 59% dengan nilai Absolute Risk Reduction (ARR) 49% dan Number Need to Treat (NNT) 2. Rerata rentang waktu sampai terjadi desaturasi pada kelompok perlakuan sebesar 46 detik dibandingkan kelompok kontrol 29,74 (p=0,142).
Kesimpulan: VTP nasal dengan kanula RAM meningkatkan keberhasilan intubasi endotrakeal neonatus dan mengurangi desaturasi. Rerata rentang waktu sampai terjadi desaturasi secara klinis bermakna antara kedua kelompok penelitian.

Background: Endotracheal intubation in neonates is a complex and risky procedure, with a low initial success rate of 20.3% primarily due to desaturation or bradycardia. Neonates who fail in the first attempt of endotracheal intubation are at increased risk of mortality and neurodevelopmental disorders. High-flow nasal (HFN) techniques have been shown to enhance the success of neonatal endotracheal intubation, but their implementation may be limited by the availability of necessary equipment in healthcare settings. Additional oxygenation techniques such as Nasal Positive Pressure Ventilation (PPV) through a RAM cannula in neonatal endotracheal intubation has not been studied.
Objective: To evaluate the efficacy of nasal positive pressure ventilation with ram cannula compared to the outcomes of endotracheal intubation in preterm neonates.
Methods: Open clinical trials conducted from January to June 2023. The research sample consists of preterm neonates with a gestational age of ≥ 25 weeks to 34 weeks with severe asphyxia or severe respiratory distress or apnea that meet the inclusion criteria. Randomization was performed and divided into 2 groups, namely the control group (standard PPV) and the treatment group (standard PPV with the addition of nasal PPV with RAM cannula).
Results: The study sample included 78 neonates consisting of 39 in the treatment groups and 39 in the control groups. The intubation success rate in the treatment group was 84.6%, significantly higher than the 41% success rate observed in the control group. This discrepancy resulted in an Absolute Risk Reduction (ARR) of 44% and a Number Needed to Treat (NNT) of 2. Furthermore, the occurrence of desaturation in the treatment group was notably lower at 10.3% compared to 59% in the control group, leading to an Absolute Risk Reduction (ARR) of 49% and a Number Needed to Treat (NNT) of 2. The mean time to desaturation in the treatment group was 46 seconds compared to 29.74 seconds in the control group (p=0.142).
Conclusion: Nasal PPV with RAM canula improves the success of neonatal endotracheal intubation and decrease desaturation episodes. There is a clinically significant difference in the mean time interval until desaturation occurs between the two research groups.
"