Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 17 dokumen yang sesuai dengan query
cover
Endah Ayu Tri Wulandari
"ABSTRAK
Latar belakang: Infeksi HIV masih banyak ditemukan di Indonesia saat ini. Terapi antiretroviral telah merubah morbiditas dan mortalitas pasien terinfeksi HIV, dan juga merubah manifestasi oral HIV/AIDS, termasuk kandidiasis orofaring KOF . Dalam penelitian ini dieksplorasi peran faktor genetik dan respons imun pasien terinfeksi HIV dengan dan tanpa KOF, sebelum dan sesudah terapi ARV.Metode: Subyek penelitian sebesar 82 pasien terinfeksi HIV, ARV-na ve dengan jumlah sel T CD4

ABSTRACT
Background HIV infection remains common in Indonesia nowadays. Antiretroviral therapy ART has altered morbidity and mortality of HIV infected people, and also altered oral manifestation of HIV AIDS, including oropharyngeal candidiasis OPC . Here we explore the role of host genetic factors and immune responses in HIV infected patients beginning ART.Methods This study included 82 ARV na ve HIV infected patients with "
2017
D-Pdf
UI - Disertasi Membership  Universitas Indonesia Library
cover
Irma Tri Aryani
"Kebijakan sistem zonasi digunakan dalam proses penyeleksian penerimaan peserta didik baru (PPDB) untuk jenjang pendidikan SMP dan SMA yang diselenggarakan oleh negara. Tujuan kebijakan ini sebagai upaya pemerintah dalam melakukan pemerataan pendidikan di Indonesia untuk menghapus stigma eklusivitas sekolah unggulan dan sekolah non-unggulan. Dalam pelaksanaan penerimaan peserta didik baru tahun 2017 dan tahun 2018 masih ditemukan tindak kejahatan; tindak jual-beli kursi, kasus pungutan liar dan kasus pemalsuan Surat Keterangan Tidak Mampu (SKTM) yang baru muncul sejak diterapkan PPDB sistem zonasi.
Dalam penulisan ini menggunakan Routine Activity Theory untuk mengidentifikasi dan menganalisis bagaimana peluang membentuk beberapa kasus kejahatan dalam proses pelaksanaan PPDB. Pengumpulan data diperoleh dari berbagai sumber laporan dan berita, serta wawancara. Hasil penelitian ditemukan bahwa peluang kejahatan terbentuk akibat rentannya target, para pelaku yang termotivasi untuk melakukan tindak kejahatan dan lemahnya pengawasan yang cakap.

The school zoning system policy is applied in the process of selecting new student admissions (PPDB) for the level of junior and senior high school education held by the state. The purpose of the school zoning system is one of the government efforts inequitable education in Indonesia to eliminating the stigma of exclusivity in schools. In the implementation of new student admissions in 2017 and 2018, crimes are still found; seat purchases, extortion, and relief letter for students from disadvantaged families (SKTM) Forgery that has emerged since the PPDB zoning system were implemented.
This writing is using the Routine Activity Theory to identify and analyze how opportunities form several criminal cases in the process of implementing PPDB. Data collection is obtained from various sources of reports and news, as well as an interview. The result found that chances of crime formed are due to the vulnerability of the targets, the motivated offenders who willing to commit crimes and lack of capable guardians.
"
Depok: Fakultas Teknik Universitas Indonesia, 2019
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Burhanuddin Ahmad
"Debit air (flowrate) yang bernilai konstan merupakan besaran fisis fundamental dalam sistem transportasi fluida dari satu tempat ke tempat lain. Untuk mencapai hal tersebut, dibutuhkan suatu sistem kendali yang mampu menghasilkan debit air bernilai konstan. Pada penelitian ini, transportasi fluida dibuat dalam sebuah rangkaian plant miniatur dengan menerapkan sistem kendali didalamnya. Pada plant tersebut terdapat actuator control valve, flow transmitter, dan Programmable Logic Controller (PLC). OPC Server merupakan perangkat lunak antarmuka menggunakan mode client/server berbasis COM/ DCOM yang memungkinkan MATLAB dapat berkomunikasi dengan PLC. Dalam proses komunikasi antara PLC dengan MATLAB digunakan OPC server yang berfungsi sebagai "jembatan" antara keduanya. Sistem kendali yang diterapkan berupa PID-Controller dan soft computing Neural Network (NN) dengan menggunakan MATLAB SIMULINK. Penerapan soft computing Neural Network (NN) bertujuan untuk mengoptimasi performa sistem kendali PID-Controller yang telah umum digunakan. Faktor-faktor performa yang dijadikan parameter pembanding adalah nilai rise time, settling time, maximum overshoot, dan steady-state error. Berdasarkan hasil percobaan, Neural Network Controller memiliki nilai permformansi yang lebih baik daripada PID-Controller. Nilai performansi Neural Network Controller yang didapatkan yakni maximum overshoot = 5.36% dan steady-state error = 0.85%.

Flowrate is a fundamental physical quantity in the fluid transportation system from one place to another. To achieve this, a control system is needed that is able to produce a constant flow of water. In this study, fluid transport was made in a miniature plant series by implementing a control system in it. At the plant there is a control valve actuator, flow transmitter, and Programmable Logic Controller (PLC). OPC Server is interface software using COM / DCOM-based client / server mode that allows MATLAB to communicate with the PLC. In the process of communication between PLC and MATLAB, the OPC server is used as a "bridge" between the two. The control system applied is in the form of PID-Controller and soft computing Neural Network (NN) using MATLAB SIMULINK. The application of soft computing Neural Network (NN) aims to optimize the performance of the PID-Controller control system that has been commonly used. Performance factors that are used as comparison parameters are the value of rise time, settling time, maximum overshoot, and steady-state error. Based on the results of the experiment, the Neural Network Controller has a better value of permformance than PID-Controller. The performance value of the Neural Network Controller obtained is maximum overshoot = 5.36% and steady-state error = 0.85%."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2019
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Muhammad Dhafa
"Kebutuhan bahan bangunan yang terus meningkat menjadi tantangan signifikan dalam perkembangan kehidupan manusia. Permintaan akan pasir dan agregat, yang merupakan bahan penting dalam pembuatan beton, diperkirakan akan terus meningkat, dengan proyeksi konsumsi pasir global mencapai 60 miliar ton pada tahun 2030. Ketersediaan terak feronikel yang melimpah di Indonesia dapat menjadi solusi pemenuhan kebutuhan agregat pada bahan bangunan. Penelitian ini membahas karakteristik secara fisik (visual, morfologi mikro, kehalusan, kekerasan) dan secara kimiawi (komposisi kimia, fasa senyawa) pada terak feronikel, dan juga mortar yang dibuat dengan campuran semen OPC tipe I dengan 100% agregat terak feronikel. Hasil penelitian menunjukkan terak feronikel memiliki kekerasan 646 HV dengan bentuk angular yang didominasi oleh tiga unsur oksida utama yautu SiO2 45,76%, MgO 27,12%, dan Fe2O3 15,92% dalam bentuk fasa mineral forsterite dan enstatite. Perhitungan parameter pengoperasian ball mill dilakukan dengan menggunakan 80% kecepatan kritis tabung mill dan 30% ball filling ratio, serta rasio fraksi bola dengan powder sebesar 0,6 untuk mengoptimalkan proses reduksi ukuran. Secara umum, mortar beragregat terak feronikel menunjukkan kuat tekan yang lebih baik daripada mortar beragregat pasir Ottawa. Pada FM 3,398, 2,349, 2,00, 1,853, dan 1,615 secara berurutan kuat tekan yang dihasilkan sebesar 32,08 MPa, 31,40 MPa, 29,15 MPa, 30,51 Mpa, dan 33,77 MPa. Tidak ditemukan hasil reaksi MgO dan pozzolanik dari terak feronikel pada proses hidrasi semen Portland.

The increasing demand for building materials poses a significant challenge in human development. The demand for sand and aggregates, which are essential materials in concrete production, is expected to continue to rise, with projected global sand consumption reaching 60 billion tons by 2030. The abundant availability of ferro-nickel slag in Indonesia can be a solution to meet the aggregate needs in construction materials. This research discusses the physical characteristics (visual, micro-morphology, fineness, hardness) and chemical characteristics (chemical composition, compound phases) of ferro-nickel slag, as well as the mortar made with a mixture of Type I OPC cement and 100% ferronickel slag aggregate. The research results show that ferro-nickel slag has a hardness of 646 HV with angular shape, predominantly consisting of three main oxide components, namely SiO2 45.76%, MgO 27.12%, and Fe2O3 15.92%, in the form of the mineral phases forsterite and enstatite. The operating parameters of the ball mill were calculated using 80% of the critical speed of the mill cylinder, a 30% ball filling ratio, and a ball-to-powder fraction ratio of 0.6 to optimize the size reduction process. Overall, the ferro-nickel slag aggregate mortar exhibits better compressive strength compared to Ottawa sand aggregate mortar. For FM 3.398, 2.349, 2.00, 1.853, and 1.615, the resulting compressive strengths are 32.08 MPa, 31.40 MPa, 29.15 MPa, 30.51 MPa, and 33.77 MPa, respectively. No MgO or pozzolanic reaction was observed from the ferro-nickel slag during the hydration process of Portland cement."
Depok: Fakultas Teknik Universitas Indonesia, 2023
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Raina S. Dryana
"Skripsi ini membahas tentang pengaruh faktor air semen (FAS) terhadap kekuatan tekan, tarik belah, dan tarik lentur beton normal yang dibuat menggunakan semen tipe Ordinary Portland Cement (OPC). Penelitian ini dilatarbelakangi oleh kebutuhan adanya gambaran hubungan antara kekuatan, umur dan FAS beton dengan semen portland tipe I yang digunakan untuk berbagai tujuan namun keberadaannya mulai tergantikan dengan semen tipe baru. Penelitian dilakukan melalui pengujian di laboratorium dengan membuat benda uji silinder beton diameter 100 mm dan tinggi 200 mm untuk uji kuat tekan sebanyak 105 buah, silinder beton diameter 150 mm dan tinggi 300 mm untuk uji kuat tarik belah sebanyak 105 buah, dan balok untuk uji kuat lentur dengan ukuran 150 mm x150 mm x 600 mm sebanyak 63 buah.
Dari hasil penelitian didapatkan bahwa semakin besar nilai FAS maka kekuatan beton yang diperoleh baik kuat tekan, kuat tarik belah, dan kuat lentur akan semakin menurun karena jumlah semen sebagai sumber kekuatan beton juga berkurang. Pengolahan data menggunakan dua metode statistik yaitu metode nilai rata - rata dan metode chi square yang menghasilkan hubungan untuk beton umur 28 hari: kuat tekan (fc - ) dengan kuat lentur (fr) adalah : fr=0.656?fc - kuat tarik belah (ft) dengan kuat lentur (fr) adalah : fr=0.967ft kuat tekan ((fc - ) dengan kuat tarik belah (ft) adalah : ft=0.666?fc - .

The focus of this study is about the effect of water cement ratio (FAS) on the compressive strength, splitting tensile strength, and flexural strength of normal concrete made using Ordinary Portland Cement (OPC). The background of this research is the need for illustrating the correlation between concrete strength, age and FAS with OPC which is used for many purposes but its existence began to be replaced with other Portland cement. This research through attempt in laboratory by making 105 samples concrete cylinder with diameter of 100 mm and 200 mm height for compressive strength test, 105 samples cylinder with diameter of 150 mm and 300 mm height for splitting tensile strength test and 63 samples beam for flexural strength test with size 150 mm x 150 mm x 600 mm.
The result shows that the greater value of FAS, the concrete strength obtained compressive strength, splitting tensile strength, and flexural strength will also decrease because the amount of cement concrete as a source of strength is also reduced. Processing data was using two statistical methods which is average value method and chi square method, produced the relationship for 28 days of concrete age : compressive strength (fc') and flexural strength (fr) : fr=0.656?fc' splitting tensile strength (ft) and flexural strength (fr) : fr=0.967ft compressive strength ((fc') and splitting tensile strength (ft) : ft=0.666?fc'.
"
Depok: Fakultas Teknik Universitas Indonesia, 2010
S50642
UI - Skripsi Open  Universitas Indonesia Library
cover
Agung Cahyadi
"Terak akhir timah merupakan produk samping hasil peleburan terak-1 yang mengandung jenis oksida serupa dengan semen Portland OPC , yaitu SiO2, CaO, Al2O3, dan Fe2O3 sehingga terdapat potensi untuk diutilisiasi sebagai beton. Penelitian ini bertujuan untuk mengetahui karakteristik OPC dan semen campuran terak-2 terhadap korosivitas material semen dan baja berdasarkan metode Electrochemical Impedance Spectroscopy EIS dan Cyclic Polarization. Penelitian ini menggunakan terak akhir timah Bangka yang dicampurkan dengan OPC masing-masing sebanyak 10 , 20 , dan 30 . Beton yang dicetak memiliki rasio 0.5 w/c dengan proses curing selama 28 hari lalu direndam di dalam larutan NaCl 3.5 selama 6 hari. Hasil analisa menunjukkan baja di dalam campuran 20 terak memiliki ketahanan korosi yang paling kompetitif dan stabil terhadap beton OPC murni, diikuti campuran 10 , dan 30 terak secara berturut-turut.

Final tin slag is a byproduct of slag 1 smelting process that contains similar oxides compared to Portland cement OPC , which is SiO2, CaO, Al2O3, and Fe2O3 so that there is potential to be initiated as a concrete. The aim of this research is to know the characteristics of OPC and cement of slag 2 mixture against corrosivity of cement and steel material based on Electrochemical Impedance Spectroscopy EIS and Cyclic Polarization methods. This study uses final tin slag from Bangka mixed with OPC each of 10 , 20 , and 30 . The molded concrete has a ratio of 0.5 w c with 28 days curing process then immersed in a 3.5 NaCl solution for 6 days. The analysis shows that the steel in 20 slag 2 concrete mixture has the most competitive and stable corrosion resistance compared to original OPC concrete, followed by 10 , and 30 slag mixture respectively."
Depok: Fakultas Teknik Universitas Indonesia, 2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Jeffry Adityapriatama
"Dengan berkembangnya konstruksi perkotaan dan kebutuhan industri, maka semakin diperlukannya pipa yang panjang. Untuk Kebutuhan industri diperlukannya sistem pengendalian yang kuat, adaptif, efisien, dan ramah lingkungan untuk memenuhi kebutuhan yang sangat besar. Pada penelitian ini telah dirancang suatu sistem kendali berbasis kecerdasan buatan dengan logika fuzzy pada pengendalian debit air berbasis PLC .Dalam penelitian ini sistem logika fuzzy menggunakan 2 input fuzzy set yaitu error dan perubahan error. Setiap Fuzzy set menggunakan 5 fungsi keanggotaan yaitu negatif besar (NB), negatif medium(NM), zero(ZO), positif medium(PM), positif besar(PB). Sistem dapat melakukan pengendalian debit sesuai yang dibutuhkan.
Sistem ini berada pada sebuah komputer yang berfungsi sebagai pusat pengendalian dan mengambil data dari OPC server dimana data tersebut diambil dari PLC menggunakan komunikasi ethernet yang langsung terhubung dengan plant. Sistem pengendalian berbasis logika fuzzy dioperaasikan pada prototype plant dalam skala lab, dan analisis performa diverivikasi secara eksperimental. Data secara langsung dapat diambil dan dilihat menggunakan SIMULINK MATLAB. Berdasarkan hasil eksperimen dapat simpulkan pengendalian menggunakan logika fuzzy lebih baik dibanding pengendalian konvesional PID. Hasil pengendalian menggunakan logika fuzzy lebih cepat mencapai steady state yaitu 24.24 sekon tanpa adanya overshoot dibandingkan dengan menggunakan PID yaitu 48.6 sekon dengan overshoot sebesar 16.2%.

With the development of urban construction and industrial needs, the need for long pipes is increasing. For industrial needs, a control system that is strong, adaptive, efficient, and environmentally friendly is needed to meet huge needs. In this study, a control system based on artificial intelligence has been designed with fuzzy logic for PLC-based water flow control. In this study, the fuzzy logic system uses 2 fuzzy set inputs, namely error and error change. Each Fuzzy set uses 5 membership functions, namely large negative (NB), medium negative (NM), zero (ZO), medium positive (PM), large positive (PB). The system can control the discharge as needed.
This system is located on a computer that functions as a control center and retrieves data from the OPC server where the data is retrieved from the PLC using ethernet communication which is directly connected to the plant. The fuzzy logic-based control system was operated on a prototype plant on a lab scale, and the performance analysis was verified experimentally. Direct data can be retrieved and viewed using SIMULINK MATLAB. Based on the experimental results, it can be concluded that controlling using fuzzy logic is better than conventional PID control. The result of controlling using fuzzy logic reaches a steady state faster, which is 24.24 seconds without overshoot, compared to using PID, which is 48.6 seconds with an overshoot of 16.2%.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2019
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
James Andrean Noel
"Beton merupakan material yang kerap digunakan dalam suatu struktur bangunan dan jembatan. Beton memiliki properti material berupa kuat tekan dan modulus elastisitas dimana kedua variabel memiliki andil besar dalam proses desain struktur. Nilai kedua parameter tersebut dapat diperoleh melalui pengujian properti material beton baik secara destruktif maupun non destruktif.
Korelasi antara pengujian destruktif dan non destruktif bersifat empiris sehingga memerlukan studi lebih lanjut dalam menilai dampak setiap variasi material pada beton. Penelitian ini melakukan pengujian destruktif dan non destruktif terhadap beton instan non OPC dimana sampel yang digunakan dalam setiap proses pengujian merupakan produk PT. Solusi Bangun Indonesia Tbk. Pengujian destruktif yang dilakukan berupa uji kuat tekan dan uji modulus elastisitas, sedangkan pengujian non destruktif yang dilakukan berupa uji Ultrasonic Pulse Velocity (UPV).
Hasil pengujian antara kedua jenis metode digunakan untuk membentuk korelasi antara pengujian destruktif dan non destruktif spesifik untuk beton dengan tipe yang sama. Pembentukan korelasi antara uji kuat tekan dengan cepat rambat gelombang menghasilkan korelasi meningkat secara eksponensial dan korelasi antara uji modulus elastisitas dengan cepat rambat gelombang menghasilkan korelasi meningkat secara logaritmik.

Concrete is a material that is often used in a building structure and bridges. Concrete has material properties in the form of compressive strength and modulus of elasticity where these two variables play a large role in the structural design process. The values ??of these two parameters can be obtained by testing the properties of the concrete material both destructively and non-destructively.
The correlation between destructive and non-destructive testing is empirical so that it requires further studies in assessing the impact of each material variation on concrete. This study conducted destructive and non-destructive tests on non-OPC instant concrete where the samples used in each testing process were products of PT. Build Solutions Indonesia Tbk. Destructive tests were carried out in the form of compressive strength tests and modulus of elasticity tests, while non-destructive tests were carried out in the form of Ultrasonic Pulse Velocity (UPV) tests.
The test results between the two types of methods are used to establish a correlation between specific destructive and non-destructive tests for concrete of the same type. Establishing a correlation between the compressive strength test and the wave propagation speed resulted in an exponentially increasing correlation and the correlation between the elastic modulus test and the wave propagation speed resulted in a logarithmically increasing correlation.
"
Depok: Fakultas Teknik Universitas Indonesia, 2023
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Wan Ahmad Alviranza
"Beton merupakan material yang paling banyak digunakan pada perencanaan infrastruktur di Indonesia. Dalam perencanaan struktur bangunan beton, terdapat beberapa parameter penting untuk menentukan kekakuan dan kualitas beton yaitu kuat tekan dan modulus elastisitas. Kedua parameter tersebut dapat ditentukan melalui pengujian destruktif dan non destruktif. Penelitian ini melakukan pengujian destruktif untuk mendapatkan nilai kuat tekan dan modulus elastisitas pada sampel beton inti menggunakan produk beton instan PakCrete dari PT. Solusi Bangun Indonesia Tbk. Selain itu, dilakukan juga pengujian non-destruktif yaitu Ultrasonic Pulse Velocity dan Ultrasonic Concrete Tomography yang bertujuan untuk mendapatkan nilai cepat rambat gelombang longitudinal dan geser pada medium perambatan berupa sampel beton. Korelasi pengujian destruktif dan non-destruktif memerlukan studi lebih lanjut dalam menilai dampak variabel uji non-destruktif terhadap material beton secara empiris. Korelasi pengujian destruktif dan non-destruktif diperoleh dari pengujian pada sampel beton dengan berbagai variasi persebaran mutu. Pembentukan korelasi antara cepat rambat gelombang dengan kuat tekan dan modulus elastisitas menghasilkan tren meningkat secara logaritmik.

Concrete is the most widely used material in infrastructure planning in Indonesia. In the design of concrete structures, there are several important parameters to determine the strength and quality of concrete, namely compressive strength and modulus of elasticity. Both parameters can be determined through destructive and non-destructive testing. This research conducts destructive testing to obtain the values of compressive strength and modulus of elasticity on core concrete samples using the instant concrete product PakCrete from PT. Solusi Bangun Indonesia Tbk. In addition, non-destructive testing, such as Ultrasonic Pulse Velocity and Ultrasonic Concrete Tomography, is also performed to obtain the values of longitudinal and shear wave velocities in the concrete sample as a propagation medium. The correlation between destructive and non-destructive testing requires further study to assess the empirical impact of non-destructive test variables on concrete materials. The correlation between destructive and non-destructive testing is obtained from testing concrete samples with various quality variations. The correlation between wave velocity and compressive strength and modulus of elasticity results in an increasing logarithmic trend."
Depok: Fakultas Teknik Universitas Indonesia, 2023
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Almer Prabaswara Swardana
"Beton merupakan salah satu material konstruksi yang paling sering digunakan. Untuk dapat mengetahui kekuatan beton pada komponen struktur eksisting, diperlukan pengujian kuat tekan pada sampel beton inti yang diambil dari komponen strukur tersebut. Kuat tekan atau mutu beton merupakan properti material beton yang seringkali menjadi perhatian dalam suatu desain struktur. Namun, modulus elastisitas juga merupakan salah satu parameter yang penting dalam suatu desain struktur, seperti menentukan kekakuan struktur beton. Oleh sebab itu, diperlukan adanya studi mengenai modulus elastisitas beton inti menggunakan material yang ada di Indonesia, yang kemudian akan dibandingkan dengan literatur digunakan. Hubungan kuat tekan dengan modulus elastisitas pada beton inti yang menggunakan semen non-OPC (yaitu PPC atau Portland Pozzolan Cement) yang diukur menggunakan 3 buah ekstensometer memiliki persamaan berupa E = 10355ln(fc’) – 10944 (dalam MPa) untuk metode ASTM C469. Bila disesuaikan dengan bentuk ACI 318-14, yaitu dalam akar dari fc’ dan konstanta tersebut dihilangkan atau intercept nol, maka persamaan yang diperoleh untuk metode ASTM C469 adalah E = 4421√fc’ (dalam MPa). Hubungan antara hasil yang didapat jika dibandingkan dengan literatur ACI 318-14 adalah nilai modulus elastisitas beton dengan semen PPC lebih rendah daripada literatur ACI 318-14 untuk mutu 14,50 MPa sampai 39,03 MPa.

Concrete is one of the most frequently used construction materials. To be able to determine the strength of the concrete in the existing structural components, it is necessary to test the compressive strength of the core concrete samples taken from these structural components. Compressive strength or quality of concrete is a property of concrete material that is often a concern in a structural design. However, the modulus of elasticity is also an important parameter in a structural design, such as determining the stiffness of a concrete structure. Therefore, it is necessary to study the modulus of elasticity of core concrete using existing materials in Indonesia, which will then be compared with the literature used. The relationship between compressive strength and elastic modulus in core concrete using non-OPC cement (ie PPC or Portland Pozzolan Cement) as measured using 3 extensometers has the equation E = 10355ln(fc') – 10944 (in MPa) for the ASTM C469 method. When adjusted to the ACI 318-14 form, namely in the roots of fc' and the constant is omitted or the intercept is zero, then the equation obtained for the ASTM C469 method is E = 4421√fc' (in MPa). The relationship between the results obtained when compared with the ACI 318-14 literature is that the elastic modulus value of concrete with PPC cement is lower than the ACI 318-14 literature for quality 14.50 MPa to 39.03 MPa."
Depok: Fakultas Teknik Universitas Indonesia, 2023
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
<<   1 2   >>