Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 17 dokumen yang sesuai dengan query
cover
St. Louis: Elsevier Mosby, 2011
616.7 FUN
Buku Teks SO  Universitas Indonesia Library
cover
Rodriguez-Gonzalez, Federico Angel
"This book reviews the biomaterials (metallic, non-metallic and bone allografts) used for orthopaedic applications and explains both the engineering and clinical aspects of their use and performance within the human body."
London: ASM International, 2009
e20451712
eBooks  Universitas Indonesia Library
cover
Magee, David J.
"Provides step-by-step guidance for evaluating movements and performing the most common special tests in musculoskeletal assessment."
Philadelphia, PA: Saunders/Elsevier, 2011
616MAGO001
Multimedia  Universitas Indonesia Library
cover
Chung, Kevin C.
Philadelphia: Saunders/Elsevier, 2008
617.575 CHU o
Buku Teks SO  Universitas Indonesia Library
cover
Chung, Kevin C.
Philadelphia: Saunders/Elsevier, 2008
617.575 CHU o
Buku Teks SO  Universitas Indonesia Library
cover
Maher, Ann Butler
Philadelphia: W.B. Saunders, 2002
616.702 31 MAH o
Buku Teks SO  Universitas Indonesia Library
cover
Magee, David J.
St. Louis, Missouri: Elsevier-Saunders, 2011
616.7 MAG o
Buku Teks SO  Universitas Indonesia Library
cover
Daradjatun M.
"ABSTRAK
Laporan pendahuluan dari patah tulang tibia terbuka derajat 3 didapat 5 kasus dengan 2 kasus derajat III A, 2 kasus derajat III B dan 1 kasus derajat III C. Walaupun belum dapat diambil kesimpulan karena belum lengkap jumlah kasus dan waktu yang diperlukan, namun pengamatan sementara dari lima kasus yang mendapat pengobatan Cypro Floxacin 2 x 750 mg maupun 2 x 500 mg secara klinis umum dan lokal dinilai baik.
Perlunya mempercepat penutupan jaringan granulasi dan "Bone expose" oleh tandur alih kulit dan flap serta mengevaluasi kuman yang muncul apakah merupakan nosokomial infeksi atau penyebab osteomyelitis di kemudian hari terutama jenis pseudomonas aerogenosa.
"
1990
T-Pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Nurul Ilmaniar
"ABSTRAK
Pengenduran pada interfasa dan infeksi pada implan merupakan dua penyebab utama dari kegagalan implan ortopedi dini. Salah satu cara untuk mencegah pengenduran pada interfasa dan infeksi pada implan adalah dengan memodifikasi permukaan implan ortopedi. Permukaan yang diinginkan akan memiliki kekasaran permukaan yang rendah serta topografi skala nano. Plasma electrolytic polishing adalah proses finishing yang diketahui akan kemampuannya dalam menghasilkan permukaan yang sangat halus dan mengkilap. Plasma electrolytic polishing dilakukan dengan variasi komposisi elekrolit dan waktu poles. Kekasaran permukaan diukur menggunakan surfcom roughness contouring detector dan topografi permukaan diamati menggunakan SEM. Hasil pengukuran kekasaran menunjukkan kekasaran permukaan paling rendah dan paling tinggi sebesar 0,0889 µm dan 0,6281µm. Pengamatan SEM menunjukkan terbentuknya struktur nano yang menyerupai kawah dengan adanya pits dan ridges pada perlakuan dengan elektrolit H3PO4, NaClO4, dan HF serta terbentuknya pits di permukaan pada perlakuan dengan elektrolit etilen glikol dan NH4F serta NaCl. Kedua struktur mengalami penghalusan seiring dengan bertambahnya waktu poles terutama pada waktu poles 90 dan 120 detik. Kenaikan kekerasan sampel mengindikasikan adanya lapisan oksida yang terbentuk di permukaan. Sampel hasil poles bebas dari sisa-sisa elektrolit sehingga mencegah kemungkinan terjadinya reaksi alergi atau kontaminasi zat toksik.

ABSTRACT

Aseptic loosening and infection are the two major causes for premature orthopedic implant failure. One of the strategies to prevent both scenarios is by modifying surface of orthopedic implant. The surface should have minimum surface roughness with nano topography. Plasma electrolytic polishing is a finishing process known for its ability to provide highly smooth and glossy surface. The two variables are electrolyte composition and polishing time.  Surface roughness is measured using surfcom roughness contouring detector and surface topography is observed using SEM. The result of surface roughness measurement shows lowest and highest surface roughness are at 0,0889 µm and 0,6281 µm. SEM observation shows crater-like nanostructure with pits and ridges with electrolyte comprised of H3PO4, NaClO4, and HF meanwhile nanotructures of pits on top of smooth surface is available with electrolyte comprised of ethylene glycol and NH4F and electrolyte comprised of NaCl. The increase of polishing time shows smoothing effects on orthopedic implant surfaces especially on 90 and 120 s. Increase in hardness of polished samples indicates the presence of oxide layer in the surface. Polished samples are free from remainder of electrolyte therefore preventing possibility of allergic reaction or contamination of substance that is toxic for the body."

2019
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Muhammad Rizky
"Pelapisan hidroksiapatit dengan doping ion antibakteri pada implan logam memiliki dampak signifikan dalam meningkatkan osseointegrasi dan mengurangi kolonisasi bakteri. Perlakuan panas pasca-deposisi juga berpengaruh terhadap sifat permukaan dan kristalinitas logam implan yang memengaruhi adhesi, proliferasi sel, dan sifat bioaktivitas. Penelitian ini menggunakan metode Pulsed Laser Deposition (PLD) dengan sumber laser Nd:YAG (? = 532 nm) untuk melapisi logam SS 316L dengan HA-Zn lalu dilakukan annealing pada temperatur 400°C, 500°C, dan 600°C selama 1 jam. Pengujian SEM dan AFM menunjukkan bahwa permukaan yang dihasilkan semakin seragam dengan peningkatan temperatur annealing, tetapi pada 600°C kekasaran lapisan HA-Zn cenderung meningkat akibat tumbuhnya partikel nano. Hasil XRD menunjukkan bahwa lapisan yang dideposisi pada substrat memiliki fasa amorf, dan kristalinitas meningkat setelah perlakuan annealing pada temperatur 400°C dan 600°C. Pengujian bioaktivitas dengan merendam sampel dalam larutan SBF selama 7 hari menunjukkan terbentuknya presipitat apatit pada semua lapisan, menunjukkan sifat bioaktivitas yang baik. Terdapat perbedaan morfologi apatit yang terbentuk pada temperatur annealing yang berbeda, akibat perubahan fasa. Pengujian sudut kontak menunjukkan bahwa semua lapisan memiliki sifat hidrofilik, dengan peningkatan sudut kontak akibat proses annealing pasca-deposisi. Dengan demikian, metode pelapisan ini menghasilkan lapisan HA-Zn dengan morfologi, sifat permukaan, dan sifat bioaktivitas yang diinginkan untuk aplikasi sebagai implan ortopedi.

Antibacterial ion doped hydroxyapatite coating on metal implants has a significant impact in increasing osseointegration and reducing bacterial colonization. Post-deposition annealing also plays a crucial role in achieving desired surface morphology, crystallinity, and bioactivity. In this study, Pulsed Laser Deposition (PLD) method using Nd:YAG laser source (? = 532 nm) was employed to coat SS 316L metal with HA-Zn, followed by annealing at temperatures of 400°C, 500°C, and 600°C for 1 hour. SEM and AFM revealed that the surface became more uniform with increasing annealing temperature. However, after annealed at 600°C, the roughness tended to increase due to the growth of nano-sized particles. XRD results showed that the deposited layer exhibited an amorphous phase, and an increase in crystallinity was observed after annealing at 400°C and 600°C. The bioactivity testing by immersing the samples in simulated body fluid (SBF) for 7 days indicated the formation of apatite precipitates on all layers, suggesting their good bioactivity properties. Morphological differences were observed in the apatite formed at different annealing temperatures, which were attributed to phase changes. The contact angle measurements demonstrated that all layers exhibited hydrophilic properties, with an increased contact angle after annealing process. In conclusion, this coating method yielded HA-Zn layers with desired morphology, surface properties, and bioactivity for orthopedic implant."
Depok: Fakultas Teknik Universitas Indonesia, 2023
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
<<   1 2   >>