Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 6 dokumen yang sesuai dengan query
cover
Toemin A. Masoem
"Registration handbook of UMPTN mentions that registration form and answer sheet will be processed by computer. It means that registration form and answer sheet will be scanned by optical mark readers that is connected to computer system. Pencil with 2B texture is the only toll that can be used to fulfill the forms. Another kind of tools will cause forms can not be processed. Meanwhile there are producers that promote a special pencil for computer. This cause confusion for many students. Furthermore, it might interfere their concentration in examinations. For student who lives in metropolitan this may not be a problem at all. But there become a problem for student who lives in remote region, since it is not easy to get that kind of pencil in remote region. It seems that computer discriminates against student from remote region.
The result of this study shows that all pencils will give a good result if it is done properly. Improper fulfillment or careless handling of the forms will give an improrer result for HB pencil or harder and for 4B pencil or softer. While B pencils and 3B pencils still give as good result as 2B pencils. This study also discovered that brand of the pencils still give as good result as 2B pencils. This study also discovered that brand of the pencil does not influence the scanning process. Scanning result only depend on the texture of pencil, not on the brand and that there is no special pencil for computer."
Depok: Fakultas Teknik Universitas Indonesia, 1998
JUTE-XII-1-Mar1998-89
Artikel Jurnal  Universitas Indonesia Library
cover
Anita Rachmawati
"Biosensor berbasis penghambatan enzim asetilkolinesterase (AChE) oleh isoprokarb berhasil dikembangkan. Elektroda pensil grafit (GPE) termodifikasi polianilin (PANI) dan nanopartikel emas (AuNPs) digunakan untuk mendeteksi perubahan respon tiokolin dengan adanya isoprokarb. Elektroda ini dipreparasi dalam dua tahap menggunakan teknik cyclic voltammetry (CV), yaitu elektropolimerisasi anilin pada GPE dan elektrodeposisi AuNPs pada permukaan GPE termodifikasi PANI. Karakterisasi yang dilakukan dengan SEM-EDX menunjukkan bahwa AuNPs berukuran 8-80 nm dapat diendapkan pada permukaan pensil grafit termodifikasi polianilin. Karakterisasi elektrokimia menggunakan CV menunjukkan peningkatan luas permukaan aktif elektroda sekitar 2 dan 3,3 kali dibandingkan dengan GPE yang tidak dimodifikasi. Selanjutnya, puncak oksidasi tiokolin yang dibentuk oleh reaksi enzimatik AChE dengan adanya asetiltiokolin dapat diamati pada potensial +0,675 V (vs. Ag/AgCl). Arus puncak yang dihasilkan turun secara linier dengan adanya isoprocarb dalam konsentrasi konstan AChE dan asetilthiocholine. Pada kondisi optimum larutan 0,1 M PBS pH 7,4 yang mengandung 100 mU/ml AChE dan 1 mM asetiltiokolin klorida, waktu kontak 15 menit dan waktu inhibisi 25 menit, kurva kalibrasi linier isoprocarb dapat dicapai pada rentang konsentrasi 0,0005 hingga 0,05 ¼M dengan batas deteksi dan kuantifikasi masing-masing 0,0106 ¼M dan 0,0355 ¼M, dengan sensitivitas 47,4810 ¼A/¼M.mm. Selanjutnya, pengukuran keberulangan menghasilkan nilai yang baik untuk 9 kali pengukuran diamati dengan RSD 4,57%, menunjukkan bahwa biosensor yang dikembangkan menjanjikan untuk mendeteksi isoprocarb.

An analysis tool for isoprocarb has been successfully developed as a biosensor system based on enzymatic inhibition of acetylcholinesterase (AChE) by isoprocarb. A gold nanoparticles-polianiline modified graphite pencil electrode (AuNPs-PANI-GPE) was utilized to detect the change of thiocholine in the presence of isoprocarb. This electrode was prepared by two cyclic voltammetry steps, including electro-polymerization of aniline on a graphite pencil and electro-deposition of gold nanoparticles on the polyaniline surface. Characterization performed by SEM-EDX indicated that 8-80 nm size of gold nanoparticles could be deposited on the surface of polyaniline-modified graphite pencil. Electrochemical characterization using cyclic voltammetry suggested that the active surface area of the prepared electrode was 0.17019 cm2, which was about 2 and 3.3 times compared to that of the unmodified GPE. Furthermore, an oxidation peak of thiocholine was observed at a potential of +0.675 V (vs. Ag/AgCl), formed by an enzymatic reaction of AChE in the presence of acetylthiocholine. This peak current was found to increase linearly with acetyl thiocholine concentrations, while in the presence of isoprocarb in a constant concentration of AChE and acetylthiocholine the peak linearly decreased. At the optimum condition of 0.1 M PBS pH 7.4 containing 100 mU/ml acetylcholinesterase and 1 mM acetythiocholine chloride, the inhibition and the contact time of 25 min and 15 min, a linear calibration curve of isoprocarb could be achieved in the concentration range of 0.0005 to 0.05 ¼M with an estimated limits of detection and quantifications of 0.0106 ¼M and 0.0355 ¼M, respectively, with the sensitivity of 47.4810 ¼A/¼M.cm2. Furthermore, an excellent stability for 9 times measurements was observed with an RSD of 4.57%, suggesting that the developed tools is promising for the detection of isoprocarb."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2023
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Asep Taopik
"Dosis radiasi yang diterima pasien pada pemeriksaan CT. Scan tidak boleh melebihi nilai dosis referensi yang telah ditentukan, sehingga perlu dilakukan evaluasi nilai dosis . Studi ini menganalisa dosis pasien pada pemeriksaan CT. Scan di RS. Husada Jakarta, Perkiraan dosis pasien ( CTDI dan DLP ) yang langsung ditampilkan pada monitor CT setiap selesai pemeriksaan akan diketahui ketepatan nilainya dengan pengukuran langsung menggunakan pencil ion chamber yang ditempatkan pada objek phantom dan dibandingkan dengan nilai dosis referensi yang telah ditetapkan, sehingga diharapkan pasien mendapatkan informasi nilai dosis yang sebenarnya. Kemudian dilakukan juga analisa variasi parameter kV, mA, dan pitch untuk menentukan berapa nilai parameter optimum untuk mendapatkan nilai dosis pasien (CTDI) yang minimum dengan kualitas pencitraan hasil CT. Scan yang baik guna menunjang diagnosa. pengukuran langsung dengan menggunakan head dan body phantom, menunjukkan nilai CTDI tidak melebihi nilai dosis referensi yang ditetapkan, namun tampilan dimonitor tidak menunjukkan kesesuaian. variasi parameter yang dilakukan dapat menentukan parameter pitch, kV, dan mA yang tepat pada setiap pemeriksaan khususnya pasien dewasa pada objek kepala, perut, dan paru - paru.

Evaluation of dose values is needed because radiation dose for patients who undergone on a CT examination do not allow to exceed reference dose values. This study analyzed patients dose on CT Scan examinations at Husada Hospital, Jakarta. Estimation of patients dose ( CTDI and DLP ) which display directly on CT monitor every the end of examination will be known accuracy of values with measuring directly used ion chamber pencil that was placed in phantom object and it was compared with reference dose values. The purpose of this step is intended to give dose values information actually for patient. In this study also analyzed parameter variation of kV, mA, and pitch in order to determine optimum parameter values to get minimum patient dose values (CTDI) with good quality of CT Scan image result to support diagnostic. Measuring directly used head and body phantom had indicated that CTDI values do not exceed reference dose values, however patients dose values that displayed on CT monitor do not indicate suitability with reference dose values. Parameter variation which had done, it could determine parameter of pitch, kV, and mA exactly in every examination especially for adult patients on object of head, abdomen, and thorax."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2007
S29331
UI - Skripsi Membership  Universitas Indonesia Library
cover
Samsun
"Perkiraan nilai dosis yang diterima pasien ( CTDI ) yang langsung ditampilkan pada monitor CT setiap selesai pemeriksaan akan diketahui ketepatan nilainya dengan pengukuran langsung menggunakan pencil ion chamber dan pengukuran tidak langsung menggunakan TLD (Thermolumescence Dosimeter ) yang ditempatkan pada objek phantom dan dibandingkan dengan nilai dosis referensi yang telah ditetapkan, sehingga diharapkan mendapatkan informasi nilai dosis yang sebenarnya.
Analisis variasi parameter kV, mAs, dan pitch untuk menentukan berapa rentang nilai parameter optimum untuk mendapatkan nilai dosis pasien (CTDI/mAs) yang minimum namun tidak mengesampingkan kualitas pencitraan hasil CT. Scan yang baik guna menunjang diagnosa, pengukuran langsung maupun tidak langsung dengan menggunakan fantom kepala dan perut.
Pengukuran tidak langsung dengan menggunakan TLD (Thermolumescence Dosimeter ) pada menunjukan hasil yang tidak jauh berbeda dengan pengukuran langsung dengan menggunakan pencil ion chamber, dapat ditunjukkan dengan hubungan sifat kelinearan antara pitch dan dosis (CTDI/mAs).

An estimation dose (CTDI) received by the patient which is directly displayed on the CT monitor on every examination will be able to known it?s precisien by direct measurement using pencil ion chamber and the indirect measurement using TLD placed on the object (phantom) and compared with the value of dose reference, so the real dose rate will be known.
The variant analysis of kV, mAs and pitch parameters to justify the range of optimal parameter value, it is used to get the minimum patient dose rate (CTDI/mAs) while the image quality for supporting the diagnose still on the right value, directly or not directly using head and abdomen phantom.
Indirect measurement using TLD show unsignificant result if compared with the ion chamber. This value is shown by a relative variant parameter using stright pitch and dose ( CTDI/mAs).
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2008
T21548
UI - Tesis Open  Universitas Indonesia Library
cover
Yakub Aqib Bayhaqi
"Pendahuluan: Radioterapi merupakan salah satu teknik penanganan kanker yang paling sering digunakan di bidang medis, khususnya menggunakan radiasi Sinar-X berenergi tinggi yang diproduksi dari pesawat radioterapi eksternal Linear Accelerator (LINAC). Diperlukan suatu algoritma yang akurat untuk memperkirakan dosis yang akan diterima oleh pasien.
Metode: Kalkulasi dengan menggunakan metode superposisi berkas pensil menggunakan kernel berukuran 1 mm x 1mm pada permukaan fantom yang didapat dari hasil simulasi menggunakan metode Monte Carlo DOSYZnrc. Energi foton yang digunakan berupa pendekatan yaitu sepertiga dari energi maksimum foton sebesar 3,33 MeV dan 2 MeV yang merepresentasikan sinar-X 10 MV dan 6 MV. Penggeseran kernel dilakukan berdasarkan posisi geometris titik terhadap sumber.
Hasil dan Pembahasan: Persentase kesalahan relatif terbesar terjadi pada permukaan fantom untuk seluruh energi. Untuk foton energy 3,33 MeV. Persentase kesalahan realtif konstan kurang dari 5% terjadi pada seluruh lapangan. Sedangkan untuk foton energy 2 MeV, persentase kesalahan realtif kurang dari 10 % dengan adanya peningkatan kesalahan untuk setiap kenaikan kedalaman. Terjadi pergeseran dmax pada seluruh lapangan. Pergeseran dmax terjadi akibat penggunaan foton monoenergetic pada kalkuasi yang mengakibatkan pengabaian energi foton yang lebih besar dan rendah dari energi rata-rata sinar-X. Ditambah lagi kalkulasi superposisi ini hanya dilakukan pada bidang 2 dimensi.
Kesimpulan dan Saran: Penelitian ini dengan secara akurat memperkirakan persentase dosis radiasi sinar-X untuk daerah efektif pada fantom. Namun kurang akurat untuk memperkirakan dosis radiasi sinar-X pada daerah build up. Dibutuhkan beberapa penambahan metode lainnya untuk mengoptimasi waktu dan akurasi kalkulasi. Seperti penggunaan metode konvolusi dan pengabaian nilai piksel pada kernel yang bernilai mendekati nol untuk memperkecil ukuran kernel agar waktu kalkulasi bisa dipersingkat.
Introduction: Radiotherapy is the most effective treatment method in treating cancer for medical treatment, particularly using the high voltage X-ray radiation generated from the Linear Accelerator (LINAC). In implementation, an accurate algorithm to estimate the dose distribution through patient is indispensable.
Method: Percentage Depth Dose (PDD) calculation can be done using the pencil-beam superposition method. 1 mm x 1mm kernel from the phantom surface obtained using the Monte Carlo DOSYZnrc simulation. Photon energy approaches used in the form of one-third of the maximum photon energy of 3.33 MeV and 2 MeV which represents the 10 MV X-rays and 6 MV. Shifting the kernel is based on the geometric position of the point source.
Results and discussion: Largest relative error occurs at the surface and in build up region of the phantom for all energies. For photon energy 3.33 MeV, error is less than 5 % in effective area. As for the photon energy 2 MeV, error is less than 10 % in effective area with a gradient for all field. The monoenergetic representation shift the dmax for all field. The error occurs due to the use of monoenergetic photons disobeying the other photon energies in the X-ray spectrum which has greater or less energies than the mean energy. It is also caused by the calculation has done in the 2 dimensional region.
Conclusion and Suggestion: This experiment accurately compute the PDD in X-ray radiation for the effective area. But it failed to compute the PDD in the build up region. A few addition of other method can optimize this superposistion method to speed the calculation time ad improve the accuration. A suppression of the kernel dimension based on its prime value that is effective to speed up the calculation. And the calculation would be followed by the convolution method principle.
"
Depok: Universitas Indonesia, 2011
S1101
UI - Skripsi Open  Universitas Indonesia Library
cover
Fera Ayu Dianovita
"Kolesterol sebagai elemen struktural utama dalam membran sel, memainkan peran penting dalam fungsi biologis. Tingkat kolesterol dalam tubuh harus dipertahankan pada level normal <5,2 mmol/L untuk mencegah hiperkolesterolemia, yang dapat menyebabkan penyakit kardiovaskular. Tujuan dari penelitian ini adalah merancang dan mengembangkan sensor MIP menggunakan elektroda grafit pensil yang difungsionalisasi dengan grafena oksida untuk mendeteksi kolesterol yang efisien, sensitif, selektif, presisi, dan stabil. Metode deteksi kolesterol telah banyak dipelajari, namun seringkali memerlukan peralatan mahal dan persiapan sampel yang rumit. Metode enzimatik saat ini efektif tetapi memiliki kelemahan berupa biaya tinggi dan degradasi enzim selama penyimpanan. Penelitian ini mengusulkan sensor elektrokimia non-enzimatik berbasis Molecularly Imprinted Polymer (MIP) dengan monomer DMAEMA pada elektroda grafit pensil (PGE) yang dimodifikasi dengan grafena oksida. Melalui optimasi parameter seperti rasio konsentrasi molekul templat terhadap monomer, jumlah siklus polimerisasi dan penghilangan molekul templat, laju polimerisasi dan deteksi, durasi rebinding, serta pH pelarut, sensor menunjukkan kinerja yang memuaskan. LOD sebesar 0,83 mM, LOQ sebesar 2,76 mM, sensitivitas 40,52 μA.μM⁻¹.cm⁻², dan rentang linear 1 - 7 mM, sensor ini menawarkan presisi dan selektivitas yang baik terhadap kolesterol. Hasil penelitian juga menunjukkan stabilitas sensor yang baik selama periode pengujian.

Cholesterol, as a principal structural element in cell membranes, plays a vital role in biological functions. The cholesterol levels in the body must be maintained at a normal level of <5.2 mmol/L to prevent hypercholesterolemia, which can lead to cardiovascular diseases. The aim of this research is to design and develop an MIP sensor using a pencil graphite electrode functionalized with graphene oxide for the efficient, sensitive, selective, precise, and stable detection of cholesterol. Cholesterol detection methods have been widely studied, yet they often require expensive equipment and complicated sample preparation. Current enzymatic methods are effective but have the disadvantages of high cost and enzyme degradation during storage. This study proposes a non-enzymatic electrochemical sensor based on Molecularly Imprinted Polymer (MIP) with DMAEMA monomer on a pencil graphite electrode (PGE) modified with graphene oxide. Through the optimization of parameters such as the ratio of template molecule concentration to monomer, the number of polymerization cycles and template molecule removal, the polymerization and detection rate, rebinding duration, and solvent pH, the sensor demonstrated satisfactory performance. LOD of 0.83 mM, LOQ of 2.76 mM, sensitivity of 40,52 μA.μM⁻¹.cm⁻², and a linear range of 1-7 mM, the sensor offers good precision and selectivity towards cholesterol. The research findings also indicate the sensor’s good stability over the testing period."
Depok: Fakultas Teknik Universitas Indonesia, 2024
T-pdf
UI - Tesis Membership  Universitas Indonesia Library