cover
Rama Aryarakhito Wongso
"The reactive power plays an important role in almost every power transmission industry. Assessing the reactive power, its component influences the voltage stability, voltage reliability, and transient stability in the grid is important to maintain the power transmission grid. Those components are also used to improve system efficiency, maintain the system ability to stand in the standard values to avoid unwanted tragedies, such as sudden voltage drop caused by sudden decrease of reactive power or when the transmission flow does not go in line caused by overloaded current increase. Those unwanted phenomena are potentially harmful to the system.
In order to adjust the reactive power level into the needed and its components that are influenced by the reactive power values, the reactive power compensation devices are strongly needed. There are already some reactive power compensation devices in the recent industry. The performance factor, reliability, and the availability are considered in this bachelor thesis. Therefore, comparison and analysis will be conducted on the reactive power compensation devices and methodologies to determine the requirement and the placing of reactive power will be conducted. The need to control the reactive power is done by some devices, and the system is made so in such way in order to maintain its qualities, these qualities are going to be discussed mainly in this bachelor thesis.

Daya reaktif memiliki peran penting di hampir setiap industri transmisi daya. Dengan daya reaktif, nilai dari komponen tersebut dapat mempengaruhi kestabilan tegangan, keandalan dan kestabilan sementara untuk menjaga jaringan transmisi listrik. Komponen-komponen tersebut juga digunakan untuk meningkatkan efisiensi sistem, menjaga kemampuan sistem untuk tetap pada nilai standar untuk menghindari tragedi yang tidak diinginkan, seperti penurunan tegangan secara tibatiba yang disebabkan oleh penurunan daya reaktif secara spontan atau ketika aliran transmisi tidak berjalan karena kelebihan beban. Fenomena yang tidak diinginkan tersebut berpotensi membahayakan sistem.
Untuk menyesuaikan level daya reaktif dan komponennya menjadi sesuai, perangkat kompensasi daya reaktif sangat diperlukan. Sudah ada beberapa perangkat kompensasi daya reaktif yang tersedia di pasar. Faktor kinerja, kehandalan, dan ketersediaan akan dibahas di dalam skripsi ini. Oleh karena itu, perbandingan dan analisis perangkat kompensasi daya reaktif dan metodologi perlu dilakukan untuk menentukan kebutuhan dan penempatan daya reaktif. Kebutuhan untuk mengontrol daya reaktif dilakukan oleh beberapa perangkat dan membuat sistem sedemikian rupa untuk mempertahankan kualitas daya reaktif yang diinginkan. Pembahasan kualitas tersebut akan dibahas di dalam skripsi ini.
"
Depok: Fakultas Teknik Universitas Indonesia, 2023
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Achmad Bambang Sumadiyana
"Salah satu faktor yang menentukan kualitas dan keandalan sistem tenaga listrik adalah pengoperasian sistem pada tegangan dan frekuensi konstan dengan rugirugi daya seminimal mungkin. Hal ini dapat diketahui dengan analisis aliran daya pada kondisi normal. Simulasi yang menggunakan ETAP dilakukan terhadap sistem 150 kV Region Jakarta-Banten dengan dua situasi yaitu penggunaan grid dan atau IBT.
Simulasi dengan menggunakan IBT menghasilkan data perhitungan yang lebih baik dibandingkan simulasi dengan menggunakan grid. Kompensasi pada suatu rel akan menyebabkan berkurangnya aliran daya reaktif menuju rel tersebut sehingga dapat mengurangi arus, rugi-rugi daya dan jatuh tegangan pada saluran serta menambah faktor daya.
One of the factors which determines quality and reliability of power system is system operation with constant voltage and frequency with minimal losses. Those can be seen using load flow analysis in normal condition. ETAP can be applied on 150 kV Region Jakarta-Banten System with two situations that are using grid or IBT.
The result of simulation using IBT is better than the simulation using Grid. The compensation at one bus will cause decreasing of reactive power to the bus, and lead to decreasing of current, power losses and voltage drop at line transmission, and increasing power factor.
"
Depok: Fakultas Teknik Universitas Indonesia, 2009
R.03.09.06 Sum s
UI - Skripsi Open  Universitas Indonesia Library
cover
Boromeus Sakti Wibisana
"KWH meter merupakan instrumen yang memiliki fungsi utama melakukan pengukuran energi listrik. KWh-meter digunakan oleh PLN untuk mendata dan menganalisa penggunaan energi oleh konsumen. KWH meter yang dikenal luas oleh masyarakat umum adalah KWH meter konvensional yang memiliki fitur terbatas. KWh-meter konvensional ini kita kenal dengan KWh-meter analog. KWh-meter analog mampu membaca jumlah pemakaian daya aktif dengan cukup baik. Namun daya reaktif yang terbaca tidak cukup baik, oleh karena itu digunakan KWh-meter digital, yang dapat membaca daya aktif dengan baik begitu juga dengan daya reaktifnya. KWh-meter digital memiliki ketelitian yang lebih baik dari pada KWh-meter analog. Ketelitian dari KWh-meter digital ini membuat PLN akan melakukan penggantian pemasangan KWh-meter analog dengan KWhmeter digital.

KWH meter is the instrument that have a main function to measure the electricity energy. KWh-meter is used by PLN to record and analyze the energy that used by consumen. KWH meter that we already know is conventional KWH meter that have limited function. The conventional KWh-meter we know as analogue KWhmeter. The analogue KWh-meter can read total amount of active power used well enough. But the reactive power can't be read as well as the active power.therefore we use the digital KWh-meter,that can read the reactive power as well as the active power. Digital KWh-meter is also more accurate than the analogue. The accuracy of the Digital KWh-meter make PLN will change the installation of the analogue KWh-meter to Digital KWh-meter."
Depok: Fakultas Teknik Universitas Indonesia, 2008
S51035
UI - Skripsi Open  Universitas Indonesia Library
cover
Octa Puara Aryani
"Kualitas tegangan merupakan salah satu persyaratan keandalan sistem penyaluran tenaga listrik yang harus dipenuhi untuk pelayanan kepada konsumen. Walaupun suatu sistem mempunyai kualitas tegangan yang baik dan stabil, belum tentu sistem dapat mempertahankan tegangan tersebut karena jatuh tegangan akan terjadi di semua bagian sistem dan akan berubah dengan adanya perubahan beban. Pada sistem transmisi, daya reaktif sangat berpengaruh pada kestabilan sistem.
Pada penelitian ini akan dibahas mengenai perbaikan tegangan dengan menambahkan Static Synchronous Compensator (STATCOM) menggunakan aplikasi perangkat lunak DIgSILENT Power Factory 14.1. STATCOM akan melakukan perbaikan tegangan dengan mengendalikan daya reaktif. Pengaturan daya reaktif oleh STATCOM terjadi dengan cara membandingkan besarnya nilai tegangan terminal antara STATCOM dengan sistem.
Simulasi dilakukan pada Bus Lengkong yang sering terjadi penurunan tegangan. Dengan penambahan STATCOM, tegangan rendah pada Bus Lengkong tersebut berhasil ditingkatkan dari 130,01 kV menjadi 135,13 kV. Kemudian dilakukan juga skenario 1 trip pembangkit pada PLTU Teluk Naga 3. Pada saat dilakukan simulasi trip pembangkit, STATCOM tidak memberikan pengaruh apapun terhadap sistem. Untuk skenario 2, ketika dilakukan penurunan kapasitas pada pembangkit yang sama, STATCOM berhasil menaikkan tegangan di sistem tetapi berada dibawah toleransi yang diizinkan SPLN.

Voltage quality is one of the requirements of the reliability of the electric power distribution system that must be met for a service to consumers. Although a system has a good quality and stable voltage, not necessarily the system can maintain the voltage due to voltage drop will occur in all parts of the system and will change with the change in load. In the transmission system, reactive power influences the stability of the system.
In this paper will discuss the improvement of voltage by adding Static Synchronous Compensator (STATCOM) using a software application DIgSILENT Power Factory 14.1. STATCOM will make improvements voltage by controlling the reactive power. STATCOM reactive power by setting occurs by comparing the value of the terminal voltage between the STATCOM system.
Simulations performed on Bus Lengkong frequent voltage drops. With the addition of STATCOM, the voltage drop on the bus Lengkong successfully upgraded from 130,01 kV to 135,13 kV. Then do the trip scenarios in PLTU Teluk Naga 3. During the simulation, STATCOM not give any influence on the system. For scenario 2, when performed on a capacity decrease in the same plant, STATCOM raise the voltage in the system but is below the allowed tolerance SPLN.
"
Depok: Fakultas Teknik Universitas Indonesia, 2015
S59260
UI - Skripsi Membership  Universitas Indonesia Library
cover
Refdinal Nazir
"This paper analyzes the effect of multiple Distributed Renewable Energy Generation penetration on improving the performance of the B3 feeder typical distribution system structure in Painan, Indonesia. Analysis uses a simple concept of load and distributed generation current injection at the distributed main, lateral and sublateral lines. The algorithm begins from completion of the main line variables, then uses an algorithm to complete the lateral line variables associated with the main line variable, and finally calls algorithms to resolve the sublateral variables associated with the lateral line variable. The results have shown that integrating three Distributed Renewable Energy Generation units to this distributed system has increased the minimum voltage of the main line from 17.35 kV to 20.37 kV, reduced active power loss from 1914.747 kW to 569.925 kW, and diminished reactive power loss from 650.747 kVAr to 188.624 kVAr."
Depok: Faculty of Engineering, Universitas Indonesia, 2016
UI-IJTECH 7:1 (2016)
Artikel Jurnal  Universitas Indonesia Library
cover
Ardiaty Arief
"This paper presents a novel analytical methodology to determine location for reactive power devices placement in power systems. The proposed method modifies modal analysis technique and develops new formulation to compute the Reactive Contribution Factor (RCF) of each load buses based on the inversed reduced Jacobian matrix. The objective of this research is to achieve the most stable condition as well as to minimize network losses. The proposed method is implemented at the modified IEEE 30-bus Reliability Test System (RTS) and compared with different placement. This work compares the voltage profile, eigenvalue and network losses to assess the method. The simulation results show the proposed method can provide a solution to the ideal shunt compensator placement to improve the system’s voltage stability and minimizing losses."
Depok: Faculty of Engineering, Universitas Indonesia, 2018
UI-IJTECH 9:3 (2018)
Artikel Jurnal  Universitas Indonesia Library