Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 7 dokumen yang sesuai dengan query
cover
Allan Asrar
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2008
S28978
UI - Skripsi Open  Universitas Indonesia Library
cover
Kiswanta
Abstrak :
ABSTRAK
PERANCANGAN SISTEM AKUISISI DATA TEMPERATUR PADA BUNDEL UJI SIMULASI EKSPERIMEN HIGH TEMPERATURE GASCOOLED REACTOR. Perancangan dilakukan untuk membangun suatu sistem pengambilan data berbasis komputer yang digunakan untuk pengukuran temperatur suatu proses eksperimen termohidraulik. Sebagai sensor temperatur digunakan termokopel tipe K (Chromel-Alumel). Kegiatan ini bertujuan untuk menyediakan fasilitas eksperimental sehingga pengujian bahan atau komponen pada kondisi temperatur tinggi sekitar 500°C -1000°C dengan aliran gas Helium dapat dilakukan. Kegiatan diawali dengan perancangan sumber pemanas, fabrikasi, komisioning dan pengujian. Komisioning dan pengujian dilakukan dengan pemanasan sampai temperatur yang dikehendaki melalui pemberian tegangan listrik yang bertahap mulai dari 10 ? 160 Volt, agar kenaikan tegangan bertahap dan tidak melonjak tinggi secara tiba-tiba. Hal ini dimaksudkan agar kekuatan heater dapat bertahan lama dan tidak cepat putus. Kegiatan yang dimulai dari desain, fabrikasi, komisioning dan pengujian berhasil dilakukan. Hasil kegiatan berupa sistem akuisisi data pada perangkat sumber pemanas yang mempunyai kemampuan pemanasan pada saat komisioning hingga temperatur 753,045°C selama 10.484 detik pada tegangan listrik 160 Volt dari tegangan maksimum 220Volt (72,73%), dengan error kesalahan pada saat kalibrasi sebesar 60C atau sekitar 1% pada temperatur di atas 6000C
Abstract
DESIGNED OF TEMPERATURE DATA ACQUISITION SYSTEM FOR HIGH TEMPERATURE GAS-COOLED REACTOR SIMULATION EXPERIMENT TESTING BUNDLE. Design carried out to build a computer based data acquisition system used for measuring the temperature of a process of experimentation termohidraulik. Thermocouples used as temperature sensor type K (Chromel-Alumel). This activity aims to provide an experimental facility to test materials or components under conditions of high temperatures around 500 °C - 1000 °C with a flow of Helium gas can be done. Activity begins with the design of heating sources, fabrication, commissioning and testing. Commissioning and testing is done by heating to a desired temperature by providing a gradual voltage from 10-160 volts, so that a gradual increase in voltage and high jump suddenly. This is so that the power of the heater can last a long time and did not quickly broken. Activities starting from design, fabrication, commissioning and testing was done. The results of the activities of a data acquisition system on the device having a heat source at the time of commissioning the heating capability of up to 753.045 °C temperature for 10,484 seconds at a voltage of 160 volts maximum voltage 220Volt (72.73%), with an error when the calibration error by 60c or about 1% at temperatures above 6000C.
2012
T31948
UI - Tesis Open  Universitas Indonesia Library
cover
Rizki Arif
Abstrak :
Dalam penelitian ini, telah dibuat sebuah sistem akuisisi data 32-channel berbasis Field Programmable Gate Array FPGA untuk mengakuisisi dan memroses sinyal Electroencephalography EEG . Sistem akuisisi data yang dibangun menggunakan board PYNQZ1, dengan Xilinx ZYNQ XC7Z20-1CLG400C All Programmable System-on-Chip APSoCs yang dapat memberikan sebuah sistem tertanam dengan performa tinggi, karena memiliki kombinasi antara fleksibilitas serta versatility dari programmable logic PL dengan prosesor embedded atau programmable system PS dengan kecepatan tinggi. Sebagai pusat dari sistem akuisisi data yang dibangun, FPGA menerima, memproses, dan menyimpan data dari Front-End Analog to Digital Converter ADC ADS1299EEG-FE. Komunikasi data yang digunakan dalam sistem akuisisi data yang dibangun adalah Serial Peripheral Interface SPI dengan konfigurasi daisy-chain. Untuk bagian pemrosesan sinyal, penulis mengimplementasikan filter bandpass Butterworth dengan orde 5 dan Fast Fourier Transform FFT pada overlay dari PYNQ-Z1. Overlay merupakan desain FPGA yang dapat dikonfigurasi sehingga menghubungkan PS pada ZYNQ dengan PL, memberikan penulis kemampuan untuk mengendalikan secara langsung platform hardware memanfaatkan Python pada PS. Rerata dari error akurasi yang didapatkan dari hasil validasi adalah 1.34 dan kriteria performa Total Harmonic Distortion THD menghasilkan 0.0091 , dengan memanfaatkan NETECH MiniSIM EEG Simulator 330. Perbandingan dari sistem akuisisi data dengan Neurostyle NS-EEG-D1 System yang mengambil data EEG yang sama menghasilkan parameter korelasi gradien dengan 0.9818, y-intercept dengan -0.1803, dan R2 dengan 0.9742 berdasarkan analisis least square. Parameter tersebut memperlihatkan sistem akusisi data yang telah dibangun cukup, jika tidak setara, dengan sistem akuisisi data komersil dengan standar medis, yaitu Neurostyle NS-EEG-D1 System, karena dapat memastikan dan mempertahankan akurasi dengan konfigurasi frekuensi sampling yang lebih tinggi. ......This study proposes a novel Field Programmable Gate Array FPGA based 32 channel data acquisition system to acquire and process Electroencephalography EEG signal. The data acquisition system is utilizing PYNQ Z1 board, which is equipped with a Xilinx ZYNQ XC7Z020 1CLG400C All Programmable SoC APSoCs that can offer high performance embedded system because of the combination between the flexibility and versatility of the programmable logic PL and the high speed embedded processor or programmable system PS . As the core of the data acquisition system, the FPGA collect, process, and store the data based on Front End Analog to Digital Converter ADC ADS1299EEG FE. The communication protocol used in the data acquisition system is Serial Peripheral Interface SPI with daisy chain configuration. For the signal processing part, we implement a 5th order Butterworth bandpass filter and Fast Fourier Transform FFT directly on the PYNQ Z1 rsquo s overlay. The overlay are configurable FPGA design that extend the system from the PS of the ZYNQ to the PL, enabling us to control directly the hardware platform using Python running in the PS. The mean accuracy error obtained from validation result of the developed system is 1.34 and the Total Harmonic Distortion THD performance criterion resulting in 0.0091 , both of them validated with NETECH MiniSIM EEG Simulator 330. The comparison between the developed system with Neurostyle NS EEG D1 System acquiring the same EEG data shows correlation parameter gradient of 0.9818, y intercept with 0.1803, and R2 of 0.9742 based on the least square analysis. The parameter above indicates that the developed system is adequate enough, if not on a par, with the commercialized, medical grade EEG data acquisition system Neurostyle NS EEG D1 as it can assure and maintain accuracy with higher sampling frequency.
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Dita Tessa Parastika
Abstrak :
Kebutuhan untuk melihat bagian dalam obyek secara non-invasive maupun non-intrusive merupakan kebutuhan yang sangat mendasar bukan hanya di dunia kedokteran tetapi juga di dalam proses industri, geologi, sistem keamanan, dan lain-lain. Di dunia kedokteran, teknologi ?melihat tembus? ini digunakan untuk keperluan diagnosa dini atau mengambil keputusan sebelum operasi. Beberapa teknologi yang telah dikembangakan antara lain CT scan, MRI, PET, dan SPECT masih memiliki dimensi yang cukup besar, tidak portable dan biaya pembuatan serta pemeliharaan yang mahal. Teknologi baru yang sekarang ini sedang berkembang seperti pencitraan gelombang mikro (microwave imaging) menawarkan beberapa kelebihan seperti biaya yang murah, portable dan bersifat non-invasive maupun non-intrusive. Oleh karena lamanya proses pengambilan data ketika proses pemindaian (scanning), maka diperlukan sistem akuisisi data yang dapat mengambil data pemindaian secara otomatis. Dalam skripsi ini, dirancang sebuah sistem akuisisi data otomatis untuk pencitraan gelombang mikro yang berbasis algoritma Algebraic Reconstruction Technique. Sistem yang dirancang berupa integrasi perangkat lunak berbasis LabVEW dan perangkat keras berupa perangkat penggerak motor stepper dan mikrokontroler Arduino yang diprogram sebagai pengendali sistem. Pengujian sistem akuisisi data dilakukan dengan menempatkan sebuah phantom uji homogen di antara dua buah antena dipol yang berfungsi sebagai transmitter dan receiver pada frekuensi 3 GHz. Selanjutnya sepasang antena dipol tersebut akan melakukan dua mekanisme untuk mendapatkan proyeksi citra, yakni gerak translasi sejauh 200 mm dan gerak rotasi dengan sudut tempuh 180 derajat. Sebagai acuan, dilakukan simulasi dengan konfigurasi yang sama menggunakan CST Microwave Studio. Berdasarkan hasil pengujian sistem akuisisi data, diperoleh hasil bahwasannya sistem memiliki tingkat akurasi (step minimum) translasi dan rotasi sebesar 0,5 mm dan 0,5 derajat saat proses pemindaian objek. Hasil pembacaan dataakuisisi normalisasi yang diperoleh memiliki kesalahan rata-rata kurang dari 5% dibandingkan dengan hasil simulasi. ...... Necesarity to see the inside of the object on non-inavasively and non-intrusively is the fundamental requirement not only in medical fields but also in industrial processes, geological, security systems, and others fields. In the medical world, the "see through" technology is used for early diagnosis or take a decision before the operation. Some developed technologies such as CT scan, MRI, PET and SPECT are considerably still bulky, non-portable and relatively high production and maintenance cost. A new growing technology called microwave imaging offers some other advantages especially low cost, portable, which still maintain on non-invasively and non-intrusively technique. Due to the imaging system that uses back projection method takes relatively long scanning process, hence, data retrieval process is required to be performed by an automatically data acquisition system. In this bachelor thesis, an automatic data acquisition system is designed for microwave imaging purpose by using Algebraic Reconstruction Techique algorithm. The acquisition system is developed as the integration of software LabVIEW-based and motor stepper hardware driver and programable microcontroller Arduino-based as the system controller. In order to validate the data acquisition system, a homogeneous phantom is placed between two dipole antennas (as a transmitter and receiver) at frequency of 3 GHz. Futhermore, the antennas will perform two mechanism to obtain the image projections, ie 200 mm translational motion and 180 degrees rotational motion. As the reference, the simulation with same configuration is design in CST Microwave Studio. According to the testing results from the proposed data acquisition system, the system has an accuracy rate (minimum step) by 0.5 mm and 0.5 degree of the translation and rotation when it scans the object. In addition, an average error of the retrieved data from the acquisition system is less than 5% compared with the simulation results.
Depok: Fakultas Teknik Universitas Indonesia, 2016
S64698
UI - Skripsi Membership  Universitas Indonesia Library
cover
Ahmad Fachri Himawan
Abstrak :
ABSTRAK
Metode pengukuran secara digital menggunakan komputer memiliki beberapa keunggulan dibandingkan dengan pengukuran dengan cara konvensional yaitu dalam hal fleksibilitas, ketelitian dan kemampuannya dalam menangani besaran-besaran yang kompleks serta berubah-ubah dengan cepat. Sistem instrumen alat pengukur kekuatan tanah triaxial menggunakan sistem akuisisi data guna mengambil dan menyimpan data hasil pengukuran secara periodik serta mengendalikan proses pengukuran. Sistem akuisisi data ini terdiri atas sistem elektronis yang berisi perangkat keras dan sistem komputer yang berisi perangkat lunak. Karena sistem akuisisi data tersebut tidak tersedia di pasar dalam negeri, maka perlu adanya usaha untuk merancang dan membuat sendiri perangkat keras dan perangkat lunaknya untuk memenuhi kebutuhan yang ada.

Perangkat keras sistem akuisisi data triaxial dibuat menggunakan modul~modul akuisisi data dari advantech (ADAM) serta beberapa rangkaian elektronika yang dirakit dengan komponen-komponen yang tersedia di pasar lokal. Perangkat lunak sistem ini dikembangkan menggunakan paket pemprograman visual Borland Delphi versi 5.Setelah dilakukan proses perancangan, pembuatan, uji coba dan analisis, ternyataperangkat keras dan perangkat lunak sistem akuisisi data triaxial dapat berfungsi dengan baik dan dapat digunakan dalam percobaan pengukuran kekuatan tanah.
2001
S39807
UI - Skripsi Membership  Universitas Indonesia Library
cover
Rian Gilang Prabowo
Abstrak :
Pengurangan jumlah penderita tumor otak yang meninggal dapat dicegah dengan salah satunya melakukan diagnosis sedini mungkin. Penanganan dalam mendiagnosis lokasi dari tumor tersebut dapat dilakukan secara non-intrusive tanpa memasukkan alat dan non-invasive tanpa merusak yang merupakan syarat untuk mencitrakan objek di dalam tubuh pada bidang kedokteran. Pencitraan gelombang mikro dapat diaplikasikan pada tomografi gelombang mikro. Untuk mencitrakan seluruh jaringan otak mampu didapatkan dengan menggunakan forward problem saja sehingga letak objek yang diinginkan tumor dapat dideteksi juga. Forward problem dapat dicapai dengan menggunakan sistem akuisisi data dengan metode rotasi dan pseudo-rotasi. Pada penelitian skripsi ini akan dirancang sebuah perancangan sistem untuk aplikasi pencitraan gelombang mikro menggunakan algoritma Algebraic Reconstruction Technique ART dengan menggunakan metode rotasi dan pseudo-rotasi. Sistem akuisisi data ini memanfaatkan dipole antenna berfrekuensi 3 GHz dan phantom berbentuk lingkaran sebagai objek. Perangkat keras yang digunakan dalam pengimplementasian sistem akuisisi data yang digunakan adalah menggunakan Signal Hound dan Switching Relay. Sistem antena yang telah dibuat dengan hasil fabrikasi memiliki nilai S11 lebih baik dibandingkan dengan hasil simulasi. Rekonstruksi citra hasil simulasi memberikan hasil yang lebih baik dibandingkan dengan hasil pengukuran, namun hasil pengukuran memberikan hasil yang lebih baik ketika piksel citra ditambahkan dari matriks 15 x 15 menjadi matriks 60 x 60. ...... Reducing the number of brain tumors that die can be prevented by one of them make a diagnosis as early as possible. Handling in diagnosing the location of the tumor can be done non intrusively non invasive and non invasive non destructive which is a requirement for imaging of objects in the body in medicine. Microwave imaging can be applied to microwave tomography. To imaging the entire issues brain can be obtained by using the forward problem only so that the location of the desired object tumor can be detected as well. Forward problem can be achieved by using data acquisition system with rotation and pseudo rotation method. In this thesis research will be designed a design system for the application of microwave imaging using Algebraic Reconstruction Technique ART algorithm using rotation and pseudo rotation method. The data acquisition system utilizes a 3 GHz dipole antenna and a cylindrical phantom as an object. The hardware used in implementing data acquisition system used is using Signal Hound and Switching Relay. The antenna system that has been made with the fabrication result has a S11 value better than the simulation result. The simulated image reconstruction gives better results than the measurement results, but the measurement results gives better results when the pixel image is added from the 15 x 15 matrix to the 60 x 60 matrix.
Depok: Fakultas Teknik Universitas Indonesia, 2017
S68306
UI - Skripsi Membership  Universitas Indonesia Library
cover
Sayid Hasan Ash Shiddiqy
Abstrak :
Aplikasi teknik biomedis berkembang dengan cepat dalam beberapa dekade terakhir. Salah satu aplikasi dalam teknik biomedis adalah pencitraan medis yang saat ini sudah diadopsi dan beberapa masih diteliti secara luas. Beberapa teknologi yang sudah diadopsi seperti CT scan, sinar-X, MRI, PET dan SPECT masih memiliki dimensi yang relatif besar, tidak portable dan biaya pembuatan serta pemeliharan yang mahal. Sekarang ini, modality baru yang sedang berkembang seperti pencitraan gelombang mikro (microwave imaging) menawarkan beberapa kelebihan lain terutama biaya yang murah, portable, dan bersifat non-invasive dan non-intrusive. Di dalam teknologi pencitraan medis, beberapa diantaranya menggunakan metode rekonstruksi citra yang berbasis algoritma proyeksi balik (back projection). Oleh karena lamanya proses pengambilan data ketika proses pemindaian (scanning), maka diperlukan sistem akuisisi data yang dapat mengambil data pemindaian secara otomatis. Dalam skripsi ini, dirancang sebuah sistem akuisisi data otomatis untuk pencitraan gelombang mikro yang berbasis algoritma proyeksi balik yang memanfaatkan transformasi Radon. Sistem yang dirancang berupa perpaduan rancangan perangkat keras dan perangkat lunak sehingga menghasilkan integrasi kedua perangkat dalam sebuah sistem akuisisi data pemindaian gelombang mikro. Perangkat lunak yang digunakan berbasis LabVIEW dan board Arduino sebagai interface dalam pengendalian rancangan sistem akuisisi. Pengujian sistem akuisisi data, dilakukan dengan menempatkan sebuah model phantom fisik homogen di antara dua buah antena dipole (sebagai transmitter & receiver) untuk dibandingkan dengan hasil simulasi dengan CST Microwave Studio pada frekuensi 3 GHz dan 5 GHz. Berdasarkan hasil pengujian sistem akuisisi data, diperoleh hasil bahwasanya sistem memiliki tingkat akurasi (step minimum) translasi sebesar 0,5 mm saat proses pemindaian objek. Hasil pembacaan data akuisisi yang diperoleh memiliki kesalahan rata-rata kurang dari 6% dibandingkan dengan hasil simulasi. ...... In few current decades, biomedical engineering applications are growing rapidly, which medical imaging is one of biomedical engineering applications that is currently widely adopted and studied for further improvement. Some existing technologies such as CT scan, X-ray, MRI, PET and SPECT are considerably still bulky, non-portable and relatively high production and maintenance cost. A new growing modality called microwave imaging offers some other advantages especially low cost, portable, which still maintain on non-invasively and non-intrusively technique. In some medical imaging systems usually still use a back projection algorithm to reconstruct the image. Due to the imaging system that uses back projection method takes relatively long scanning process, hence, data retrieval process is required to be performed by an automatically data acquisition system. In this bachelor thesis, an automatic data acquisition system is designed for microwave imaging purpose by using back projection algorithm that employing Radon transform. The acquisition system is designed as a blend of hardware design and software resulting in the integration of the both in a data acquisition system for microwave imaging. The software developed is a LabVIEW-based and Arduino board is set as an interface for controlling the designed acquisition system. In order to validate the data acquisition system, a homogeneous physical phantom is placed between two dipole antennas (as a transmitter and receiver) and the measured result is compared to the the simulation with CST Microwave Studio at the frequency of 3 GHz and 5 GHz. According to the testing results from the proposed data acquisition system, the system has an accuracy rate (minimum step) by 0.5 mm of the translation when it scans the object. In addition, an average error of the retrieved data from the acquisition system is less than 6% compared with the simulation results.
Depok: Fakultas Teknik Universitas Indonesia, 2015
S60141
UI - Skripsi Membership  Universitas Indonesia Library