Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 48 dokumen yang sesuai dengan query
cover
Faletra, Francesco Fulvio
"Questo volume di ecocardiografia si propone di trattare il tema della valvola mitrale nei suoi aspetti normali e patologici, aggiornandone la trattazione in base ai più recenti sviluppi della tecnologia. L’approccio interdisciplinare nella diagnosi e nella scelta dei trattamenti ha caratterizzato il taglio medico-divulgativo dell’opera e il linguaggio chiaro e conciso del testo, rivolto anche ai cardiologi clinici e non ai soli ecocardiografisti. Ampio spazio è dedicato quindi all’eziologia e alla fisiopatologia della valvulopatia mitralica."
Milano: [, Springer], 2012
e20410731
eBooks  Universitas Indonesia Library
cover
"PURPOSE: To evaluate and compare the clinical outcomes and hospital costs of using sutureless aortic valves vs conventional stented aortic valves.
METHODS: Between 2007 and 2011, 52 elderly patients undergoing aortic valve replacement for aortic stenosis in our center had a sutureless valve inserted. From among 180 patients who had a stented valve inserted during the same period, 52 patients were matched to the sutureless group, based on age, gender, and operation type. We compared clinical outcomes and hospital costs between the two groups.
RESULTS: The sutureless group had a higher Euroscore (logistic Euroscore I) risk (12,8 vs 9,7; p = 0,02), with significantly shorter aortic cross-clamp (ACC) time (p<0,01), cardiopulmonary bypass (CPB) time (p<0,01), intensive care unit stay (p<0,01), intubation time (p<0,01), and overall hospital stay (p=0.05). The sutureless group also revealed a significant hospital cost saving of approximately 8200 (p=0,01).
CONCLUSIONS: The clinical and hemodynamic outcomes of using the sutureless bioprosthesis were excellent. The reduced ACC and CPB times had a favorable effect on the duration of intubation and intensive care stay, resulting not only in faster recovery and discharge home, but also in a significant hospital cost reduction."
Tokyo: Springer, 2017
AJ-Pdf
Artikel Jurnal  Universitas Indonesia Library
cover
A.H. Ghanie
"Background. Spontaneous Echo Contrast (SEC) appears as a curling motion of echo in real lime and this indicates Wood stasis, ft is therefore predictive for thrombus formation and higher risk for thrombocmbolic phenomenon. Accumulating evidence showed higher incidence of (hrombus formation in mitral stenosis (MS) patients if they presented with positive SEC. Detection of left atrial thrombus is even more important before mitral valvuloplasty procedure to prevent .systemic and especially cerebral embolism. The aim of this study was to compare the utility of transthoracal eehocardiography (TIE) to transesophageal cchocardiography (TEE) in detecting SEC and thrombus in patients with MS.
Method. Forty-eight patients with MS were studied with TEE and TTE. The diagnosis of MS was established by TTE.
Result. With TTE, 15 patients (31,3%) had positive SEC, 33 patients (68, 7%) had negative SEC and 6 patients (12,5%) of the SEC positive patienls had thrombus in LA. On the other hand with TEE, SEC were positive in 36 (75%) patients, negative in 12 (25%) patients and 17 (35,4%) of the SEC positive patients showed LA thrombus. This study confirmed the strong association between SEC and thrombus formation, as thrombus was only observed in SEC positive patients.
Conclusion. TEE is superior to TTB in detecting SEC and LA thrombus in patients with MS, because of the belter acoustic window of TEE. TEE should be considered in every patients with MS where thrombus formation has to be ruled out, particularly before baloon mitral valvuloplasly procedure.
"
2002
AMIN-XXXIV-2-AprJun2002-52
Artikel Jurnal  Universitas Indonesia Library
cover
Aziz Mansykur Lubad
"Dalam industri pengolahan minyak dan gas bumi, istilah relief valve berkaitan erat dengan istilah pressure relief valve (PRV), pressure safety valve (PSV) dan safety valve. Relief valve merupakan jenis valve yang digunakan untuk mengontrol atau membatasi tekanan dalam suatu sistem. Tujuan utama dari relief valve adalah untuk menjamin personal dan peralatan operasi terlindungi dari kondisi tekanan berlebih (overpressure). Relief valve didesain untuk mencegah terjadinya kecelakaan dengan cara melepas tekanan berlebih yang terjadi selama gangguan proses, kegagalan sistem, dan kebakaran. Perhitungan yang akurat terhadap kapasitas relief valve merupakan salah satu faktor kunci dalam keselamatan kilang. Penentuan kapasitas dan jenis relief valve membutuhkan analisis proses yang mendalam dari sistem yang akan diproteksi. Tujuan dari studi ini adalah menentukan kapasitas dan jenis relief valve berdasarkan analisis proses dengan menggunakan alat bantu simulasi proses dan pemrograman visual basic. Komposisi dan kondisi operasi gas dari salah satu lapangan gas Pertamina Jambi digunakan sebagai studi kasus. Selanjutnya dilakukan analisis proses untuk mengetahui penyebab terjadinya overpressure. Simulasi proses digunakan untuk membuat Process Flow Diagram (PFD) dan menghasilkan neraca massa dan panas sedangkan pemrograman visual basic digunakan untuk menghitung kapasitas relief valve.

In the oil and natural gas processing, the term relief valve is associated with the terms pressure relief valve (PRV), pressure safety valve (PSV) and safety valve. A relief valve is a type of valve used to control or limit the pressure in a system. The primary purpose of the pressure relief system is to ensure that the operation?s personnel and equipment are protected from overpressure conditions. It is designed to avoid accidents by relieving overpressure that happen during process upsets, power failures, and external fires. Accurately calculation for the relief valve capacity is key factor of plant safety. It requires deeply process analysis of system will be protected. The purpose of this study is to determine the relief valve capacity and type base on process analysis using process simulation dan visual basic programming. The gas composition and operating condition from Pertamina Jambi gas field is used as a case study. Then, process analysis is performed to know cause of overpressure. Process simulation is used to create Process Flow Diagram (PFD) and generate heat and material balance while visual basic programming is used to calculate the relief valve capacity."
Depok: Fakultas Teknik Universitas Indonesia, 2010
T27947
UI - Tesis Open  Universitas Indonesia Library
cover
Estu Rudiktyo
"ABSTRAK
Latar Belakang. Penyakit jantung katup masih banyak ditemui di Indonesia, akan tetapi karena keterbatasan fasilitas kesehatan, banyak pasien yang terlambat mendapatkan intervensi. Keterlambatan intervensi akan mengakibatkan peningkatan morbiditas dan mortalitas. Beberapa studi besar seperti EuroSCORE dan STS telah mengembangkan model prediksi mortalitas pasca pembedahan katup jantung, akan tetapi sedikit sekali studi terkait yang dilakukan di Indonesia, padahal terdapat perbedaan karakteristik pasien. Studi ini bertujuan mengidentifikasi faktor-faktor yang dapat menjadi prediktor kejadian mortalitas di rumah sakit pada pasien yang menjalani pembedahan katup jantung.
Metode. Studi kohort retrospektif dilakukan di Pusat Jantung Nasional Harapan Kita, Jakarta pada pasien yang menjalani pembedahan katup jantung.
Karakteristik demografi, parameter klinis, data laboratorium, ekokardiografi dan teknis operasi merupakan kategori dari variabel yang dikumpulkan melalui rekam medis dan sistem informasi rumah sakit. Data kemudian diolah dengan analisis multivariat menggunakan metode regresi logistik.
Hasil. Sebanyak 305 sampel berhasil dikumpulkan, dengan 24 diantaranya mengalami kematian (7.9%). Variabel yang berkaitan dengan mortalitas adalah kelas fungsional, riwayat diabetes, endokarditis aktif, riwayat operasi jantung sebelumnya, kadar hemoglobin, TAPSE dan durasi CPB dan jenis operasi. Uji diskriminasi dan kalibrasi dari model menunjukkan hasil yang baik.
Kesimpulan. Beberapa variabel telah diidentifikasi merupakan prediktor mortalitas pasca operasi katup jantung. Informasi ini diharapkan dapat membantu menentukan strategi tatalaksana selama intervensi dan perawatan

ABSTRAK
Background. Valvular heart disease still become one of the leading heart disease in Indonesia. Unfortunately, because of very limited cardiac centres, many patients diagnosed late. Delay in intervention would increase the morbidity and
mortality rate if intervention ultimately performed. Several surgical mortality prediction models such as EuroSCORE and STS had been developed. However, until now, there is no specific mortality risk assessment in our population, despite very different in patients characteristics. Aim of this study is to identify risk factors to predict in-hospital mortality in patient underwent heart valve surgery Methods. A retrospective cohort study, done in National Cardiovascular Center Harapan Kita, Jakarta in patients underwent heart valve surgery. Categories for data obtained was basic characteristics, clinical examinations, echocardiography and operation procedure. Statistical analysis was done using multivariat analysis using logistic regression method.
Result. 305 subjects fit the inclusion and exclusion criteria. Mortality event occured in 24 patients (7.9%). The variables are functional class III or IV, diabetes, active endocarditis, previous open heart surgery, hemoglobin level, TAPSE, CPB time and type of operation. Calibration and discrimination test of prediction model shows good result.
Conclusion. Several variables has been identified as predictor of in-hospital mortality after heart valve surgery. These information are expected to be helpful in deciding intervention and treatment strategies."
Jakarta: Fakultas Kedokteran Universitas Indonesia, 2014
T-Pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Abdul Razak
"Sistem keran biasanya digerakkan secara manual oleh manusia dengan cara memutar atau menggerakkan keran ke atas atau ke bawah. Namun sistem keran secara manual ini memiliki kelemahannya yaitu keran yang mudah rusak dan pemborosan air dikarenakan kelalaian menutup keran. Dengan memanfaatkan sensor Passive Infrared (PIR) dan Ultrasonik sebagai pendeteksi objek berupa anggota tubuh manusia dan mengirimkan sinyal tersebut ke Mikrokontroler ATMEGA8535 sebagai pusat pengendalinya. Mikrokontroler ini akan mengirimkan instruksi untuk menggerakkan solenoid valve yang berfungsi sebagai katup aliran air. Hasil penelitian menunjukkan bahwa sensor PIR ini dapat mendeteksi objek dalam jarak maksimum 3 meter dan sensor Ultrasonik mendeteksi jarak sampai 4 meter. Ketika sensor PIR menerima radiasi panas dari objek, maka solenoide valve membuka katu untuk mengalirkan air. Begitu juga dengan Ultrasonik Ketika sensor Ultrasonik menerima pantulan bunyi dari objek didepannya dalam jarak tertentu maka solenoide valve membuka katup untuk mengalirkan air. Di samping itu dibutuhkan debit air tertentu untuk dapat mengaktifkan solenoide valve

Water valve usually manual controlled by human with spin up or spin down but water valve manual system have negative side which this water valve easily destroyed and close the water valve. From that use passive infrared sensor ( PIR ) and Ultrasonic sensor as object detector in human organ and transimite that signal to microcontroller ATMEGA35 as central controller. This Microcontroller will transmit some instruction to spin the solenoid valve which used to water controler. Based on observasion this Passive Infrared sensor can detection motion with the maximum distance 3 meter and ultrasonic sensor detection until 4 meter. When PIR sensor receive calor radiation from object that solenoid valve will be open. Same with solenoid valve the ultrasonic sensor receive signal from in front the sensor. Beside that needed water debit to can make solenoid valve active condition"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2008
TA-pdf
UI - Tugas Akhir  Universitas Indonesia Library
cover
Nurrul Ahmad Hidayat
"Telah dibuat alat yang dapat mengisi dan mengepres gelas plastik secara otomatis berbasis mikrokontroller. Menggunakan ATmega 16 yang mana programnya dapat diubah sesuai dengan keinginan. Disini proses pengisian air, pengemasan dan pengambilan hasil produksi dengan adanya pendorong keatas
mengunakan motor semuanya dikontrol oleh mikrokontroller

Has created a tool that can fill a plastic cup and pressing automatically based microcontroller. Using the program ATmega 16 which can be modified in
accordance with the desire. Here the process of water filling, packaging and making products with the driver of the motor uses up all controlled by the microcontroller
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2010
TA-pdf
UI - Tugas Akhir  Universitas Indonesia Library
cover
Putera Birawa Noraga
"ABSTRAK
Pada penelitian ini dilakukan analisa terhadap tiga alternatif Unit Proses untuk Menurunkan Titik Embun Gas yaitu JT Valve, refrigerasi dan Turbo Ekspander agar didapatkan unit proses yang paling laik untuk diaplikasikan pada Lapangan XYZ di PT. X.Analisa yang pertama adalah analisa secara teknis menggunakan perangkat lunak Unisim R390.1 dengan parameter teknis adalah suhu gas keluaran Unit Proses untuk Menurunkan Titik Embun Gas sama dengan 60 oF. Hasil dari analisa teknis ini adalah ketiga alternatif proses tersebut laik secara teknis.Analisa selanjutnya adalah analisa keekonomian menggunakan metode levelized cost dengan parameter keekonomian adalah NPV > 0 dan IRR > 10 . Dari ketiga alternatif proses, hanya alternatif proses 2 sistem refrigerasi yang laik secara ekonomi. Alternatif proses 2 memiliki nilai NPV = 2,9 juta US dan IRR = 52 . Kata kunci: JT Valve; Sistem Refrigerasi; Turbo Ekspander; Unit Proses Untuk Menurunkan Titik Embun Gas

ABSTRACT
this study, there is an analysis of three DPCU process alternatives i.e. JT Valve, refrigeration and Turbo Expander to obtain the most feasible process unit to be applied in XYZ Field at PT. X.The first analysis is technical analysis using Unisim R390.1 software with technical parameter is the output gas temperature of the DPCU equal to 60 0F. The result of this technical analysis is that the three process alternatives are technically feasible.The next analysis is economic analysis using the levelized cost method with economic parameters are NPV 0 and IRR 10 . From the three process alternatives, only process alternative 2 is economically feasible. Process alternative 2 has a value of NPV 2.9 million US and IRR 52 . Keywords DPCU JT Valve Refigeration System Turbo Expander"
2017
T48205
UI - Tesis Membership  Universitas Indonesia Library
cover
Yu-Ning Hu
"ABSTRACT
Infective endocarditis (IE) is associated with high mortality and morbidity and requires surgical intervention in about half of all patients. Mitral valve repair (MVrep) is reported to achieve better results than mitral valve replacement because the insertion of a prosthesis during active infection is avoided. However, MVrep in active IE is complicated and no definitive guidelines have been compiled. The current study reviews the literature from 2000 to 2016 and summarizes the surgical details of MVrep for IE."
Tokyo: Springer, 2018
617 SUT 48:10 (2018)
Artikel Jurnal  Universitas Indonesia Library
cover
Saragih, Wendy Marmalata
"Latar Belakang: Pasien yang menjalani bedah katup mitral cenderung mengalami penurunan fungsi ventrikel kanan Vka pasca pembedahan katup. Disfungsi Vka pasca pembedahan katup dapat menetap ataupun mengalami perbaikan di kemudian hari. Banyak faktor yang dapat mempengaruhi perbaikan fungsi Vka pasca operasi. Namun, belum ada studi yang menilai faktor-faktor yang dapat menjadi prediktor perbaikan fungsi Vka pasca operasi katup mitral dalam suatu studi multivariat.
Tujuan: Mengidentifikasi faktor-faktor apa saja yang dapat menjadi prediktor perbaikan fungsi Vka pada pasien dengan penyakit katup mitral yang mengalami disfungsi Vka segera setelah pembedahan katup mitral.
Metode: Penelitian ini merupakan studi kohort retrospektif yang dilakukan di Rumah Sakit Jantung dan Pembuluh Darah Harapan Kita RSJPDHK . Subjek penelitian adalah pasien yang menjalani operasi katup mitral di RSJPDHK sejak Januari 2016 sampai dengan Februari 2017. Data yang diambil yakni karakteristik dasar, data operasi, data obat-obatan pasca operasi, pemeriksaan ekokardiografi sebelum, segera sebelum lepas rawat, dan enam bulan pasca operasi.
Hasil penelitian: Sebanyak 100 subjek yang dinilai pada penelitian ini. Terdapat 68 68 subjek yang mengalami kenaikan fungsi Vka, dan 32 subjek 32 yang tidak. Median TAPSE sebelum lepas rawat meningkat secara signifikan enam bulan pasca operasi dari 1,1 0,6-1,5 menjadi 1,4 0,7-2,8 dengan nilai p

Background In patients undergoing mitral valve surgery, right ventricular function may decline immediately after the surgical procedure. This condition may sometimes remain, but may also improve later on. Many factors have been proposed to account for this phenomenon. As of yet, there are no studies using multivariate analysis to investigate factors that may be predictors of right ventricular function improvement after mitral surgery.
Objective This study aims to identify factors that may be predictors of right ventricular function improvement in patients with right ventricular dysfunction following mitral valve surgery.
Methods This is a retrospective cohort study, taking place at National Cardiovascular Center Harapan Kita NCCHK , Jakarta, Indonesia. Subjects are patients who underwent mitral valve surgery between January 2016 until February 2017. Data taken include basic characteristics, surgical data, drugs prescribed after surgery, and echocardiography data before surgery, predischarge, and six months after surgery.
Results There are 100 subjects who fulfilled the criteria to participate in this study. There are 68 68 cases of right ventricular function improvement and 32 32 cases without improvement. The median of predischarge TAPSE increases significantly six months after surgery, from 1,1 0,6 1,5 to 1,4 0,7 2,8 with p value.
"
Jakarta: Fakultas Kedokteran Universitas Indonesia, 2017
SP-pdf
UI - Tugas Akhir  Universitas Indonesia Library
<<   1 2 3 4 5   >>