cover
Arif Budiman
Abstrak :
Telah dilakukan pengembangan sistem registrasi 2D/2D untuk verifikasi posisi pasien radioterapi berbasis bahasa C++ dengan tiga metode yaitu rigid transform, Viola-Wells mutual information dan Mattes mutual information. Implementasi sistem registrasi citra otomatis yang dikembangkan menggunakan data sekunder 34 pasien kanker nasofaring didapatkan hasil koreksi maksimum untuk rigid transform sebesar (2,79 ± 0,41) mm, Viola-Wells mutual information sebesar (2,77 ± 0,64) mm dan Mattes mutual information sebesar (2,69 ± 0,68) mm. Namun dalam proses uji validasi menggunakan fantom CIRS tidak berhasil dilakukan karena kontras citra EPID setelah melalui tahapan pre-processing tidak jauh berbeda. ...... Has been developed registration system 2D/2D for verifying patient’s radiotherapy position based on C++ languages which consist of 3 registration methods such as rigid transform, Viola-Wells mutual information and Mattes mutual information. Implementation of automatic image registration system that has been developed using secondary data from 34 Nasopharyngeal Cancer patients are obtained maximum correction at about (2,79 ± 0,41) mm, (2,77 ± 0,64) mm and (2,69 ± 0,68) mm for rigid transform, Viola-Wells mutual information and Mattes mutual information, respectively. However in the validation test using CIRS phantom is not success because the image contrast of EPID after pre-processing was not significantly different.
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2014
S58654
UI - Skripsi Membership  Universitas Indonesia Library
cover
Rahmi Febriani
Abstrak :
[ABSTRAK
Hroksiapatit merupakan jenis biomaterial sintetis yang mempunyai fasa yang paling stabil dibandingkan dengan senyawa kalsiun fosfat lainnya, selain itu hidroksiapatit memiliki tingkat kemiripan yang tinggi dengan tulang, sehingga hidroksiapatik banyak diaplikasikan sebagai bone graft sintetis. Tujuan dari penelitian ini adalah untuk mengetahui pengaruh waktu sintering terhadap kemurnian kristal hidroksiapatit yang dihasilkan. Hidroksiapatit dari prekursor kimia CaCO3 dan (NH4)2HPO4 disintesis dengan menggunakan metode hidrotermal pada temperatur 150oC dan 300oC. Hasil dari sintesis hidroksiapatik dikarakterisasi dengan menggunakan X-Ray Diffraction (XRD), Scanning Electron Microscopy (SEM), dan Energy Dispersive Analysis X-Ray (EDX). Hasil karakterisasi XRD memperlihatkan intensitas tertinggi rata-rata berada pada sudut 2θ yaitu, 25.898o, 31.789o, 32.216o, 32.922o, 46.729o, dan 49.524o. Hasil dari SEM memperlihatkan morfologi dari sampel bebrbetuk nanoroot dan hasil dari EDX menunjukan rasio Ca/P sebesar 1.8. ABSTRACT
Hydroxyapatite is the most phase-stable syntetic biomaterial compared to another calcium phospate material. Hydroxyapatite also has high similarity with bone which make it has wide application as syntetic bone graft. Purpose of this research is to study the effect of sintering time towards hydroxyapatite crystal?s purity. Hydroxyapatite made from chemical precursor CaCO3 and (NH4)2HPO4 was synthesized using hydrothermal method on 150oC and 300oC. Synthesized hydroxyapatite was characterized using X-Ray Diffraction (XRD), Scanning Electron Microscopy (SEM), and Energy Dispersive Analysis X-Ray (EDX). The result of characterization showed that highest average intensity on 2θ were: 25.898o, 31.789o, 32.216o, 32.922o, 46.729o, and 49.524o.;Hydroxyapatite is the most phase-stable syntetic biomaterial compared to another calcium phospate material. Hydroxyapatite also has high similarity with bone which make it has wide application as syntetic bone graft. Purpose of this research is to study the effect of sintering time towards hydroxyapatite crystal?s purity. Hydroxyapatite made from chemical precursor CaCO3 and (NH4)2HPO4 was synthesized using hydrothermal method on 150oC and 300oC. Synthesized hydroxyapatite was characterized using X-Ray Diffraction (XRD), Scanning Electron Microscopy (SEM), and Energy Dispersive Analysis X-Ray (EDX). The result of characterization showed that highest average intensity on 2θ were: 25.898o, 31.789o, 32.216o, 32.922o, 46.729o, and 49.524o.;Hydroxyapatite is the most phase-stable syntetic biomaterial compared to another calcium phospate material. Hydroxyapatite also has high similarity with bone which make it has wide application as syntetic bone graft. Purpose of this research is to study the effect of sintering time towards hydroxyapatite crystal?s purity. Hydroxyapatite made from chemical precursor CaCO3 and (NH4)2HPO4 was synthesized using hydrothermal method on 150oC and 300oC. Synthesized hydroxyapatite was characterized using X-Ray Diffraction (XRD), Scanning Electron Microscopy (SEM), and Energy Dispersive Analysis X-Ray (EDX). The result of characterization showed that highest average intensity on 2θ were: 25.898o, 31.789o, 32.216o, 32.922o, 46.729o, and 49.524o., Hydroxyapatite is the most phase-stable syntetic biomaterial compared to another calcium phospate material. Hydroxyapatite also has high similarity with bone which make it has wide application as syntetic bone graft. Purpose of this research is to study the effect of sintering time towards hydroxyapatite crystal’s purity. Hydroxyapatite made from chemical precursor CaCO3 and (NH4)2HPO4 was synthesized using hydrothermal method on 150oC and 300oC. Synthesized hydroxyapatite was characterized using X-Ray Diffraction (XRD), Scanning Electron Microscopy (SEM), and Energy Dispersive Analysis X-Ray (EDX). The result of characterization showed that highest average intensity on 2θ were: 25.898o, 31.789o, 32.216o, 32.922o, 46.729o, and 49.524o.]
Universitas Indonesia, 2015
S62144
UI - Skripsi Membership  Universitas Indonesia Library
cover
Titi Panilia
Abstrak :
[ABSTRAK
Hidroksiapatit (HA) mempunyai peran penting dalam bidang medis karena komposisi kimia dan strukturnya yang mirip dengan tulang manusia. Material ini disintesis melalui metode hidrotermal dengan prekusor Ca(NO3)2, CaO dan NH3PO4. Variasi temperatur hidrotermal pada 150 ̊C dan 300 ̊C, temperatur sintering pada 900 ̊C selama 3 jam. Endapan yang diperoleh diuji dengan XRD dan SEM-EDX. Morfologi partikel hasil karakterisasi SEM berbentuk batangan memanjang dan melingkar teraglomerasi dan hasil uji EDX menunjukkan rasio Ca/P yang lebih besar dari 1.67. Uji XRD menunjukkan adanya fasa kalsium difosfat, fluorapatit dan apatit karbonat tipe- A di dalam endapan yang meningkatkan rasio Ca/P. ABSTRACT
Hydroxyapatite (HA) posseses significant role in medical application due to its similarity in chemical and structure to human bones. This material was synthesized through hydrothermal method using Ca(NO3)2, CaO and NH3PO4. Hydrothermal temperature varied on 150 ̊C and 300 ̊C, sintering temperature on 900 ̊C for 3 hours. Sample was characterization by XRD and SEM-EDX. Morphology observed by SEM is agglomerated round- spherical- shape particle with Ca/P ratio more than 1.67 measured by EDX. Calcium diphospate, fluorapatite and carbonated type- A presence is observed by XRD.;Hydroxyapatite (HA) posseses significant role in medical application due to its similarity in chemical and structure to human bones. This material was synthesized through hydrothermal method using Ca(NO3)2, CaO and NH3PO4. Hydrothermal temperature varied on 150 ̊C and 300 ̊C, sintering temperature on 900 ̊C for 3 hours. Sample was characterization by XRD and SEM-EDX. Morphology observed by SEM is agglomerated round- spherical- shape particle with Ca/P ratio more than 1.67 measured by EDX. Calcium diphospate, fluorapatite and carbonated type- A presence is observed by XRD., Hydroxyapatite (HA) posseses significant role in medical application due to its similarity in chemical and structure to human bones. This material was synthesized through hydrothermal method using Ca(NO3)2, CaO and NH3PO4. Hydrothermal temperature varied on 150 ̊C and 300 ̊C, sintering temperature on 900 ̊C for 3 hours. Sample was characterization by XRD and SEM-EDX. Morphology observed by SEM is agglomerated round- spherical- shape particle with Ca/P ratio more than 1.67 measured by EDX. Calcium diphospate, fluorapatite and carbonated type- A presence is observed by XRD.]
Universitas Indonesia, 2015
S62145
UI - Skripsi Membership  Universitas Indonesia Library
cover
Armando Aldy Ruddyard
Abstrak :
ABSTRAK
Karbonat hidroksiapatit merupakan suatu jenis biomaterial yang memiliki kompatibilitas tinggi dengan tulang manusia. Tujuan penelitian ini adalah untuk mempelajari pengaruh suhu dan waktu sintering untuk mendapatkan karbonat hidroksiapatit yang disintesis dengan metode hidrotermal menggunakan CaCO3 sebagai salah satu komponen. Sampel hasil sintesis dikarakterisasi dengan Fourier-transform infrared spectroscopy, x-ray diffraction, dan scanning electron microscope. Hasil FTIR menunjukkan bahwa kandungan gugus CO3 pada sampel yang dihasilkan sebanding dengan kuantitas CaCO3 yang digunakan dalam sintesis. Hasil XRD menunjukkan bahwa kandungan karbonat apatit meningkat dan kandungan kalsit menurun dengan meningkatnya suhu dan waktu sintering. Kalsit tidak terlihat pada suhu sintering 900 ̊C dan waktu sintering 2 jam.
ABSTRACT
Carbonated hydroxyapatite is a biomaterial with high biocompatibility with human bone, moreso than regular hydroxyapatite, making it an acceptable synthetic bone graft material. The purpose of this research is to study the effect of sintering temperature and time on carbonated hydroxyapatite samples synthesized using the hydrothermal method with CaCO3 as one of its components. The samples are then characterized using Fourier-transform infrared spectroscopy, x-ray diffraction, and a scanning electron microscope. IR spectra show that the CO3 content in each sample is proportional to the amount of CaCO3 used in the synthesis of said samples. Diffraction patterns from XRD show an increase in apatite content and a decrease in calcite content as sintering temperature and time increases, with temperature increases having a stronger effect on the samples than time increases. Calcite disappears completely after sintering at 900 ̊C for 2 hours.
2016
S63451
UI - Skripsi Membership  Universitas Indonesia Library
cover
Tutta Aurum Nisauf
Abstrak :
ABSTRAK
Penelitian ini diajukan dalam rangka melanjutkan penelitian sebelumnya oleh Wibowo (2015) tentang evaluasi Gamma Index (GI) untuk material homogen dan inhomogen dengan teknik IMRT. Penelitian ini dilakukan dengan menggunakan film gafchromic EBT3 sebagai detektornya. Kemudian, registrasi antara image dosis planar TPS dengan image hasil pengukuran menggunakan film dilakukan. Perencanaan radioterapi telah disiapkan sebanyak 5 pasien menggunakan modalitas FBCT, TPS Philips Pinnacle3, energi foton 6 MV, teknik IMRT 50 segment, dan CGR 0.2 cm. Evaluasi GI dilakukan dengan DD 2%, DTA 2 mm dan DD 5% DTA 3%, SAD 100 cm, dan kedalaman pengukuran pada phantom yaitu 5 cm dan 10 cm. Hasil penelitian menunjukkan GI pada material homogen lebih tinggi daripada material inhomogen. Selisih rata-rata hasil pengukuran GI terhadap penelitian sebelumnya untuk material homogen berkisar 1.98% (kedalaman 5 cm) dan 2.05% (kedalaman 10 cm) dan untuk material inhomogen sebesar 2.98% (kedalaman ekuivalen 5 cm) dan 4.59% (kedalaman ekuivalen 10 cm).
ABSTRACT
This study was the extended work which has been done by Wibowo (2015) about Gamma Index (GI) evaluation for homogeneous and inhomogeneous material with IMRT techniques. This study was done to evaluate the gamma index for registering between the planar of dose planning and the measurement from EBT film. Treatment plan was simulated for 5 patients using FBCT modality, Philips Pinnacle3 planning system, 6 MV photon energy, 50 segments IMRT technique, and calculation grid resolution (CGR) of 0.2 cm. GI evaluation was done with criteria of dose difference (DD) of 2%, dose to agreement (DTA) of 2 mm and DD of 5% DTA of 3 mm, SAD 100 cm, depth of 5 cm and 10 cm of the phantom. The result shows that GI for homogeneous material is greater than for inhomogeneous material with discrepancy to previous work is about 1,98% for homogeneous material (depth 5 cm) and 2.05% (depth 10 cm) while it was found of 2,98% for inhomogeneous material (equivalent depth 5 cm) and 4.59% (equivalent depth 10 cm).
2016
S63793
UI - Skripsi Membership  Universitas Indonesia Library
cover
Muchammad Zulfikar Ramadhan
Abstrak :
Dalam melakukan diagnosa terhadap gejala penyakit paru-paru para dokter biasanya menggunakan stetoskop sebagai alat bantu dalam melakukan proses auskultasi. Namun proses auskultasi yang dihasilkan oleh dokter sering berbedabeda hal ini dikarenakan adanya perbedaan kepekaan telinga dan pengalaman dokter yang bersangkutan. Dengan perancangan system instrumentasi untuk identifikasi dan analisis suara paru-paru menggunakan dsp tms320c6416t ini diharapkan akan membantu dalam menganalisa suara paru-paru terutama fokus pada suara normal dan suara adventitious. Interpretasi grafik dalam bentuk spectrogram dan scalogram akan mempermudah analisa suara paru-paru sekaligus mengatasi masalah keterbatasan pendengaran dalam proses auskultasi. Metode yang digunakan dalam analisa suara paru-paru meliputi transformasi fourier yang kemudian berkembang menjadi short time fourier transform (STFT) hingga tingkat lanjut seperti Wavelet transform digunakan sebagai tool untuk analaisa suara paru-paru. Upaya filtering dengan filter digital agar dapat memperoleh suara paru-paru yang sebenarnya terletak pada frekuensi antara 100-2000 Hz. ......In diagnosed the symptoms of lung disease, doctors usually use a stethoscope as an aid in the process of auscultation. However, the interpretation of auscultation process by a doctor is not usually same with another doctor. The reason has based on the differences in the sensitivity of the ear and the experience. Using tms320c6416t dsp as instrumentation system for identification and analysis of lung sound is expected to assist in analyzing lung sound that focus on normal and adventitious sounds. Interpretation of graphs in the form of the spectrogram and scalogram will simplify the analysis of lung sounds as well as minimize or avoid the limitations of hearing problems in the process of auscultation. The method used in lung sound analysis include Fourier transformation that developed into a short-time Fourier transform (STFT) till the next stage such as the wavelet transform that used as a tool for lung sounds analysis. Digital filter is used on the instrumentation system to distinguish lung sound signal from noise signal that have frequency between 100 and 2000 Hz.
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2012
S42078
UI - Skripsi Open  Universitas Indonesia Library
cover
Rosalina Tjandrawinata
Abstrak :
ABSTRAK Gigi yang lebih putih sering dianggap lebih menarik dari lebih sehat. Agar lebih putih orang seringkali melakukan pemutihan gigi dengan bahan karbamid peroksida. Penelitian ini dilakukan untuk mengetahui pengaruh aplikasi karbamid peroksida 10 % dan stannous fluorida 0,4 % pada kristalit hidroksiapatit dalam email gigi dengan metode difraksi sinar-x. Sebagai pembanding digunakan bahan perendam hidrogen peroksida 10 % dan sebagai kontrol digunakan akuades. Aplikasi bahan perendam dilakukan selama 192 jam, dengan penggantian bahan setiap 8 jam dan perendaman akuades 8 jam di antara waktu penggantian bahan perendam. Perendaman dilakukan pada suhu 37°C dan kelembaban 100%, sesuai kondisi di dalam mulut. Pemeriksaan difraksi sinar-x dilakukan setelah perendarnan 96 dan 192 jam. Selain penghitungan ukuran kristalit, dilakukan juga penghitungan konstanta kisi dan regangan (strain). Dari penelitian ini diketahui bahwa penggunaan bahan perendam karbamid peroksida, stannous fluorida, kombinasi kedua bahan dan hidrogenperoksida tidak menyebabkan perubahan ukuran kristalit dan konstanta kisi kristal hidroksiapatit email gigi secara bermakna, tetapi mengubah regangan dalam butir kristal secara berarti. Dari pemeriksaan difraksi sinar-x terlihat bahwa kristal hidroksiapatit pada bagian fasial email gigi memiliki preferred orientation pada bidang [002]. Untuk melihat keadaan permukaan sampel dilakukan pemeriksaan dengan mikroskop elektron (SEM) yang menunjukkan terjadinya perubahan pada perrnukaan email gigi akibat perendaman dalam karbamid peroksida, stannous fluorida dan hidrogen peroksida. Untuk mengetahui pengaruh keasaman perendam dilakukan pemeriksaan pH dengan pH-meter digital. Hasil pemeriksaan menunjukkan bahwa derajat keasaman (pH) bahan perendam tidak berpengaruh terhadap kerusakan pada email gigi.
ABSTRACT Carbamide peroxide has recently been widely used as a vital tooth whitener. The successful result and the simple use of the material have captured the esthetic interest of the dental practitioners. On the other hand, in some cases this bleaching material can cause pulpal sensitivity that can be cured by using stannous fluoride gel. The purpose of this experiment is to study the influence of 10 % carbamide peroxide and 0,4 % stannous fluoride application on the crystallite of hydroxyapatite in tooth enamel, by using x-ray diffraction method. Hydrogen peroxide solution and aquadest are used as control. The materials are applied for 8 hours in incubator with 37°C dan 100 % humidity, for total 192 hours.Then it can be concluded that carbamide peroxide and stannous fluoride do not influence neither the crystallite size of tooth enamel nor the lattice parameters, but they influence the strain in crystal. The x-ray diffraction on the facial surface of enamel shows preferred orientation patern at [002]. The application of the carbamide peroxide and hydrogen peroxide materials cause damage on the tooth enamel surfaces that can be detected by scanning electron microscope. In this experiment, the acidity of the materials is detected by digital pH-meter.
Depok: Universitas Indonesia, 1997
T-Pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Rosa Dian Teguh Pratiwi
Abstrak :

Dosimetri lapangan kecil dan non-standar yang berkaitan dengan penggunaan berkas Flattening Filter Free (FFF) merupakan sebuah tantangan karena adanya efek pertubasi yang disebabkan oleh desain detektor. Fenomena ini mendorong para peneliti untuk melakukan studi lebih lanjut mengenai respon detektor. Pada penelitian ini, dilakukan pemisahan radiasi hamburan dan berkas primer dari berkas FFF 6 MV untuk mempelajari respon detektor pada masing-masing kondisi pengukuran sehingga peranan setiap fenomena yang mempengaruhi respon detektor dapat dipahami dengan lebih baik. Detektor bilik ionisasi dan film Gafchromic digunakan pada tiga konfigurasi pengukuran yang merepresentasikan pengukuran lapangan terbuka dan pendekatan terhadap pengukuran dalam berkas primer dan radiasi hamburan, dirincikan sebagai berikut: (i) detektor diposisikan di bawah blok baja, sehingga detektor hanya terpapar radiasi hamburan; (ii) detektor diposisikan dalam mini phantom, sehingga detektor terpapar berkas primer dengan radiasi hamburan minimum; (iii) detektor diposisikan pada lapangan standar terbuka yang merupakan superposisi berkas primer dan radiasi hamburan. Hasil pengukuran menunjukkan bahwa respon detektor bergantung pada desain detektor (seperti ukuran volume aktif) terutama pada lapangan kecil. Respon pada lapangan terbuka dapat direproduksi dari konfigurasi berkas primer dan hamburan dengan diskrepansi 1,0 – 36%. Efek volume averaging dan efek pertubasi detektor yang mempengaruhi respon detektor dapat teramati pada konfigurasi berkas hamburan. 


Small fields dosimetry which related to the use of FFF beams is a great challenge because of perturbation effects caused by the size of the detector’s active volume or detector’s materials. This phenomenon encourages researchers to do further study about detectors response. In this work, scatter and primary radiation from 6 MV FFF beams were studied to evaluate the detectors’ response in small fields for a better understanding in the contribution of every phenomenon. Ion chamber and Gafchromic films were used in three measurement configurations representing open field measurement and approximations of both primary and scatter part of the beam, described as follows: (i) detectors positioned under steel block, exposing the detectors only to scatter part of radiation field, (ii) detectors positioned inside mini phantom, approximating the detectors response to primary radiation with minimum scatter, (iii) detectors positioned in the standard open field, which was the superposition of the primary and scatter radiation. The results showed that detector responses were heavily depended on its design (i.e. active volume) especially in small beams. The response in the open field could be reproduced from the blocked and primary beam set-up with the discrepancy ranging from 1.0% to 36%. Moreover, the volume averaging and detectors’ perturbation effects affecting the detector response could be observed in blocked beam.

2019
T52437
UI - Tesis Membership  Universitas Indonesia Library
cover
Tuti Amaliai
Abstrak :
Demi pengembangan ilmu pengetahuan, menyetujui untuk memberikan kepada Universitas Indonesia Hak Bebas Royalti Non-Eksklusif (Non-exclusive Royalty-Free Right) atas karya ilmiah saya yang berjudul : "Dose calculation in asymmetric fields 6 MV X-ray with independent jaws and individual block" beserta perangkat yang ada (bila diperlukan). Dengan Hak Bebas Royalti Non-Eksklusif ini Universitas Indonesia berhak menyimpan, mengalihmedia/format-kan, mengelolanya dalam bentuk pangkalan data (database), mendistribusikannya, dan menampilkan/mempublikasikannya di Internet atau media lain untuk kepentingan akademis tanpa perlu meminta ijin dari saya selama tetap mencantumkan nama saya sebagai penulis/pencipta dan sebagai pemilik Hak Cipta. Segala bentuk tuntutan hukum yang timbul atas pelanggaran Hak Cipta dalam karya ilmiah ini menjadi tanggung jawab saya pribadi. Telah dilakukan pengukuran persentase dosis kedalaman (PDD), profil, output factor, dan faktor koreksi dosis berkas sinar-X 6 MV pesawat linear accelerator varian CLINAC 2100C untuk lapangan simetris dan lapangan asimetris setengah tertutup (half blocked) dan asimetris tidak teratur 10 x 10 cm2 dan 20 x 20 cm2 dengan SSD 100 cm, menggunakan independent jaws dan individual block. Secara umum, PDD untuk lapangan asimetris mempunyai nilai PDD yang lebih rendah dari lapangan simetris. Profil lapangan asimetris setengah tertutup (half blocked) mempunyai profil yang sama dengan lapangan simetris dengan menggunakan sudut wedge kecil. Pengukuran dengan lapangan asimetris tidak teratur, untuk titik pengukuran tepat dibawah blok dibandingkan dengan pengukuran tanpa blok, terjadi pengurangan intensitas sebesar 12.8% dan 5% untuk lapangan 10x10 cm2 pada kedalaman 5 dan 10 cm. Untuk lapangan 20x20 cm2 sebesar 24.6% dan 9.7% pada kedua kedalaman tersebut. Koreksi faktor keluaran untuk lapangan asimetris bervariasi sesuai ukuran lapangan. Perbedaan deviasi yang terjadi antara perhitungan dan pengukuran dosis untuk lapangan asimetris setengah tertutup (half blocked) dan lapangan asimetris tidak teratur dengan ukuran luas lapangan 10 x 10 cm2 dan 20 x 20 cm2 mencapai dibawah 2 % untuk semua kasus.;Demi pengembangan ilmu pengetahuan, menyetujui untuk memberikan kepada Universitas Indonesia Hak Bebas Royalti Non-Eksklusif (Non-exclusive Royalty-Free Right) atas karya ilmiah saya yang berjudul : ?Dose calculation in asymmetric fields 6 MV X-ray with independent jaws and individual block ? beserta perangkat yang ada (bila diperlukan). Dengan Hak Bebas Royalti Non-Eksklusif ini Universitas Indonesia berhak menyimpan, mengalihmedia/format-kan, mengelolanya dalam bentuk pangkalan data (database), mendistribusikannya, dan menampilkan/mempublikasikannya di Internet atau media lain untuk kepentingan akademis tanpa perlu meminta ijin dari saya selama tetap mencantumkan nama saya sebagai penulis/pencipta dan sebagai pemilik Hak Cipta. Segala bentuk tuntutan hukum yang timbul atas pelanggaran Hak Cipta dalam karya ilmiah ini menjadi tanggung jawab saya pribadi.
2007
T21288
UI - Tesis Membership  Universitas Indonesia Library
cover
Zaenal Arifin
Abstrak :
ABSTRAK Telah dilakukan penelitian pengaruh tanggapan detektor kamera gamma SPECT dan evaluasi pengaruhnya pada pemeriksaan fungsi tiroid dan ginjal dengan citra planar. Pengukuran tanggapan detektor menggunakan sumber 1 mCi sampai 25 mCi 99mTc diletakkan dalam fantom akrilik pada kedalaman 10 cm, yang dideteksi bergantian oleh kedua detektor dengan kondisi geometri sama. Hasil tanggapan detektor 1 relatif lebih tinggi 6 sampai 16 %, namun kedua detektor masih mempunyai linieritas yang tinggi. Pemeriksaan tiroid dilakukan pada 5 orang pasien dengan 2 kali pemeriksaan dan pemindaian selama 5 menit, setiap pasien menerima 4 mCi 99mTc perteknetat dan pengambilan citra dengan detektor 1. Selanjutnya pasien menerima 2 mCi 99mTc perteknetat dan pengambilan citra dengan detektor 1 dan 2. Evaluasi hasil citra 4 mCi lebih jelas, kontras tinggi dan noise rendah dibanding citra 2 mCi. Evaluasi nilai uptake tiroid dengan kedua pemeriksaan tidak ada perbedaan signifikan. Pemeriksaan ginjal dilakukan pada 4 orang pasien dengan 2 kali pemeriksaan dalam interval waktu 5 bulan. Setiap pasien diberikan aktivitas 4 mCi 99mTc DTPA dan pemindaian selama 20 menit menggunakan detektor 1 dan 2 secara bergantian. Evaluasi hasil laju cacah detektor 1 relatif lebih tinggi dan hasil citra detektor 1 relatif lebih jelas. Evaluasi nilai uptake ginjal, GFR dan fungsi transit waktu dengan kedua pemeriksaan tidak ada perbedaan yang signifikan. Tanggapan detektor 2 telah mengalami degradasi dibanding detektor 1 namun masih linier terhadap aktivitas, sehingga belum menunjukkan perubahan yang signifikan untuk pemeriksaan klinis fungsi tiroid dan ginjal.
ABSTRACT It has been a research on the impact of SPECT gamma detector response and the evalution of impact on the examination of thyroid and kidney function with planar imaging. Research conducted by measuring the detector response 99mTc source of 1 mCi to 25 mCi at depth of 10 cm acrylic phantom, that is detected by both detector with the same geometry condition by turns. The result of detector 1 response is relatively higher 6 to 16% but the both detector has high linearity. Thyroid examination was done 5 patients with twice of examination and scanning for 5 minutes, each patient receives 4 mCi 99mTc pertechnetat and imaging with detector 1. Then, patient receives 2 mCi 99mTc pertechnetat and imaging with detector 1 and 2. The result of 4 mCi image evaluation is obtained clearer images, high contrast and low noise than 2 mCi image. The evaluation of thyroid uptake for two of examination did not differ significantly. Renal examination was done 4 patients with twice of examination in time interval 5 months. Each patient receives 4 mCi 99mTc DTPA and scanning for 20 minutes using detector 1 and 2 by turns. Evaluation of count rate detector 1 is higher relatively and the result of image detector 1 is clearer relatively. Evaluation of renal uptake, GFR and time transit function did not differ significantly. Response of detector 2 has been degradation compared with detector 1 but is still linear with respect to activity, so it hasn?t showed no differ siginificantly for thyroid and kidney function examination.
Depok: Universitas Indonesia, 2013
T32674
UI - Tesis Membership  Universitas Indonesia Library