Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 5 dokumen yang sesuai dengan query
cover
Weni Puspitasari
"Tujuan: Menilai perubahan lapisan air mata dan parameter meniskus air mata
menggunakan Optical Coherence Tomography (OCT) sebelum dan sesudah
pemakaian lensa kontak hydrogel konvensional dan silikon hydrogel. Metode: 52
sukarelawan miopia ringan-sedang dilibatkan dalam penelitian ini dan dipilih
secara acak untuk menggunakan bahan hydrogel (Nelfilcon-A) pada satu mata dan
bahan silikon hydrogel (Lotrafilcon-B) pada mata sebelahnya selama 14 hari.
Pemeriksaan lapisan air mata dilakukan melalui pemeriksaan Non-invasive Tear
Breakup Time dan Schirmer-1, serta parameter meniskus air mata menggunakan
OCT sebelum dan 14 hari sesudah penggunaan lensa kontak. Hasil: Subjek terdiri
dari 80,8% perempuan dan 19,2% laki-laki, dengan usia rerata 22,8±1,79 tahun.
Median delta NIBUT (pre-post) adalah -3,4 detik (-11,3-1,4) pada kelompok
Nelfilcon-A dan -4,6 detik (-18,5-2,7) pada kelompok Lotrafilcon-B (p=0,008).
Median delta Schirmer 1 didapatkan tidak terdapat perbedaan bermakna antara
kedua kelompok LKL. Median delta tinggi meniskus air mata pada adalah -18,5 (-
57,0-96,0) μm pada kelompok Nelfilcon-A dan -11,5 (-53,0-87,0) μm pada
kelompok Lotrafilcon-B (p=0,556). Median dimensi delta area meniskus air mata
adalah -1795,0 (-7596-4372) μm2 pada kelompok Nelfilcon-A dan -1181,5 (-8188-
8770) μm2 pada kelompok Loftrafilcon-B (0=0.728) μm2. Median delta volume
meniskus air mata adalah -0.08 (-0.29-0.18) μL pada kelompok Nelfilcon-A dan -
0.08 (-0.32-0.34) pada kelompok Lotrafilcon-B. Tidak ditemukan adanya
perbedaan bermakna antara parameter meniskus air mata di kedua kelompok LKL.
Tidak terdapat korelasi antara NIBUT, tes Schirmer-1 dan parameter meniskus air
mata. Kesimpulan: Penggunaan lensa kontak Nelfilcon-A harian dan Lotrafilcon-
B mingguan selama 2 minggu dapat menyebabkan perubahan lapisan air mata
(NIBUT memendek dan penurunan parameter meniskus air mata)."
Jakarta: Fakultas Kedokteran Universitas Indonesia, 2019
SP-Pdf
UI - Tugas Akhir  Universitas Indonesia Library
cover
Adisti
"Latar Belakang: Bertambahnya jumlah penderita miopia di dunia menyebabkan terjadinya peningkatan jumlah pengguna Lensa Kontak Lunak (LKL). Di Indonesia, prevalensi miopia sebesar 26.1% pada tahun 2002 dan diperkirakan akan meningkat setiap tahunnya. Pemaikaian LKL memiliki efek samping berupa terjadinya inflamasi pada kornea dan konjungtiva, yang ditandai oleh peningkatan kadar Interleukin-6 (IL-6) pada air mata. Tujuan: Mengevaluasi peningkatan kadar IL-6 pada air mata pada pengguna LKL harian tipe hidrogel konvensional dan LKL mingguan tipe silikon hidrogel serta meninjau korelasinya dengan tingkat inflamasi konjungtiva. Metodologi (Method): Penelitian ini merupakan suatu uji eksperimental randomisasi acak terkontrol dengan desain dua kelompok paralel, yaitu satu subjek miopia yang diterapi menggunakan LKL Hydrogel Nefilcon-A harian di satu mata, dan menggunakan LKL Silicone Hydrogel Lotrafilcon-B mingguan di mata lainnya, selama 14 hari. Tindakan foto konjungtiva, dan pengambilan sampel air mata untuk IL-6 dilakukan sesaat sebelum pemakaian LKL dan 14 hari setelah pemakaian LKL. Hasil: Seratus mata dari 50 pasien dilibatkan dalam penelitian ini. Dari seluruh subjek tersebut, 80,8% adalah perempuan dan 18,2% laki-laki dengan usia rata-rata 22,18±1,79 tahun. Median delta IL-6 sebelum dan setelah penggunaan LKL adalah 6,37 (0,05 — 1115,80) pg / mL untuk silikon hidrogel dan 4,46 (0,01 - 685,40) pg / mL untuk hidrogel konvensional. Tidak didapatkan perbedaan bermakna antara kadar IL-6 pra dan pasca LKL pada kedua grup (p=0,117). Kesimpulan: Kadar IL-6 pada air mata mengalami peningkatan signifikan setelah 14 hari penggunaan LKL pada kedua kelompok. Tetapi peningkatan kadar IL-6 pada air mata tersebut tidak disertai dengan peningkatan hiperemia konjungtiva.

Background: The increasing number of myopia patient in the world, causes growth in Soft Contact Lenses (SCL) users. In Indonesia, the prevalence of myopia was 26.1% in 2002 and is expected to increase every year. SCL usage has proven to increase cytokine production, especially Interleukin-6 (IL-6) which accompanied by inflammation of the ocular surface such as conjunctival hyperemia. Objective: Comparing IL-6 tear levels and their correlation with conjunctival inflammation scale between overnight wear silicone hydrogel SCL and daily wear hydrogel SCL. Methods: This study is a randomized controlled trial between two parallel groups. A myopia subject, who has never used SCL before, being treated using daily Hydrogel (Nefilcon-A) SCL in one eye, and overnight Silicone Hydrogel (Lotrafilcon-B) SCL in the other eye, for 14 days. The slit lamp examination, conjunctival photographs, and tear sampling for IL-6 were done before and 14 days after SCL usage. Results: One hundred eyes from 50 patients were included in this study. Of those patients, 80,8% were female and 18,2% male with mean age 22,18±1,79 years old. Median of IL-6 delta (pre-post) SCL usage was 6,37 (0,05 — 1115,80) pg / mL for silicon hydrogel and 4,46 (0,01 - 685,40) pg / mL for conventional hydrogel (p = 0,117). There were no significant difference between the initial and final conjunctival hyperemia scales in both groups (p=1,000). The correlation between IL-6 tear levels and conjunctival hyperemia was not significant (p = 0.234). Conclusion: There were a significant increase of IL-6 tear levels after 14 days of SCL usage in both groups. But the marked escalation of tear IL-6 levels was not accompanied by increasing scales of azconjunctival hyperemia."
Depok: Fakultas Kedokteran Universitas Indonesia, 2019
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Bachtiar Arif Wicaksono
"Penelitian ini bertujuan untuk mengetahui kesesuaian antara SDE dengan
analisis ImageJ dalam menilai hiperemia konjungtiva pada pemakaian LKL dalam
2 minggu. Penelitian ini merupakan studi analitik prospektif berpasangan dengan
100 subjek mata dari 50 orang dengan miopia yang belum pernah menggunakan
LKL sebelumnya. Penilaian hiperemia konjungtiva dengan SDE dan imageJ
dengan mengevaluasi foto konjungtiva yang diambil pada sebelum, hari ketujuh,
dan keempat belas penggunaan LKL. Subjek terdiri dari 80,8% (n=42) perempuan
dengan rerata usia 22,12±1,79 tahun. Awal evaluasi didapatkan terbanyak
hiperemia trace (49%) dan ringan (51%) pada konjungtiva bulbar dan hiperemia
trace (92%) pada limbus. Evaluasi imageJ didapatkan median densitas vaskular
11,80 (4,56-17,61) %area dan rerata diameter vaskular 85,81±4,07 μm. Terdapat
peningkatan hiperemia konjungtiva tingkat ringan sebesar 19% dan sedang 6%
antara setelah 2 minggu penggunaan LKL. Terdapat perbedaan diameter (p<0,05)
dan densitas vaskular (p=0,000) yang bermakna secara statistik setelah pemakaian
LKL selama 2 minggu. Pada hari keempatbelas, persentase terbanyak yaitu
hiperemia menetap (59%) dan meningkat sebesar 35% pada konjungtiva bulbar
keseluruhan. Didapatkan peningkatan 1 tingkat SDE sebesar 33% dan peningkatan
2 tingkat SDE sebesar 2% setelah pemakaian LKL 2 minggu. Terdapat kesesuaian
pada penilaian hiperemia konjungtiva bulbar dan limbus antara SDE dengan
densitas dan diameter vaskular dengan perbedaan antar masing-masing kelompok
SDE yang bermakna (p<0,05).

This study aimed to evaluate the conformity of EGS with ImageJ analysis
in assessing conjunctival hyperemia in SCL use within 2 weeks. This is a paired
prospective analytic study which included 100 eyes from 50 subjects with myopia
who have not used SCL routinely before. Conjunctival hyperemia assessments were
done with EGS and ImageJ with evaluating conjunctival images taken at before,
day 7, and day 14 of using SCL. Subjects were 80,8% (n=42) female with mean age
of 22,12±1,79 years old. At initial evaluation, there were trace (49%) and mild
(51%) grade hyperemia in bulbar conjunctiva and trace hyperemia (92%) in limbus.
ImageJ evaluation found medial vascular density of 11.80 (4.56-17.61)% area and
mean vascular diameter of 85,81±4,07 μm. There was an increase of mild grade
conjunctiva hyperemia of 19% and moderate grade of 6% between before and after
2 weeks of using SCL. There was a significant difference of vascular diameter
(p<0.05) and density (p=0.000) after using SCL for 2 weeks. At day 14 evaluation,
most percentage was found persistent grade (59%) and increasing grade (35%) in
overall bulbar conjunctiva. There were 1 EGS grade increase of 33% and 2 grades
increase of 2% after using SCL for 2 weeks. Good conformity was found in bulbar
conjunctiva and limbal hyperemia evaluation between EGS and vascular density
and diameter with significant difference between each EGS group (p<0.05)"
Jakarta: Fakultas Kedokteran Universitas Indonesia, 2019
T59130
UI - Tesis Membership  Universitas Indonesia Library
cover
Firdha Malisa Fauzia
"Latar Belakang: Berada pada periode kritis perkembangan visual, anak-anak merupakan kelompok yang memiliki risiko tinggi mengalami gangguan penglihatan. Salah satu upaya deteksi dini gangguan penglihatan pada anak adalah melalui program skrining kesehatan anak sekolah. Guru dapat didelegasikan menjadi petugas skrining di sekolah, namun perlu menjalani pelatihan agar memiliki pengetahuan dan keterampilan yang adekuat. Penelitian ini bertujuan untuk mengembangkan modul pelatihan yang valid untuk melatih guru Sekolah Menengah Pertama (SMP) dan Sekolah Menengah Atas (SMA) di DKI Jakarta dalam melakukan pemeriksaan mata pada anak sekolah
Metode : Penelitian ini menggunakan pendekatan mixed method dengan metode exploratory sequential yang terdiri atas dua tahapan. Tahapan pertama adalah penyusunan rancangan modul pelatihan dengan desain penelitian deskriptif kualitatif. Tahapan ini diawali dengan pengumpulan materi modul melalui focus group discussion (FGD), wawancara individu, dan tinjauan kepustakaan. Setelah dilakukan analisis, dilakukan pengembangan rancangan modul serta penyusunan dan validasi instrumen untuk penelitian tahap kedua. Tahapan kedua adalah uji validitas modul pelatihan. Uji validitas konten dilakukan dengan mengirimkan modul pelatihan dan kuisioner google form kepada validator dan dianilisis menggunakan I-CVI (item-level content validity index). Uji validitas konstruk diadakan bersamaan dengan pelatihan 20 guru di SMP 55 dan SMA 31 Jakarta yang berupa evaluasi pengetahuan (pre-test & post-test) dan uji keterampilan peserta pelatihan.
Hasil : Dari hasil analisis FGD dan wawancara, modul dikembangkan melalui enam tahapan. Uji validitas konten modul memiliki nilai 1.00. Pada pelatihan, didapatkan perbedaan bermakna skor pengetahuan guru antara sebelum dan setelah menjalani pelatihan (p=0.000), sedangkan 100% peserta memiliki keterampilan yang baik dalam melakukan pemeriksaan. Modul pelatihan pemeriksaan mata anak sekolah oleh Guru SMP dan Guru SMA di DKI Jakarta memiliki validitas konten dan validitas konstruk yang baik.
Kesimpulan : Modul pelatihan pemeriksaan mata pada anak sekolah oleh Guru SMP dan Guru SMA di DKI Jakarta memiliki validitas konten dan validitas konstruk yang baik.

Background: Children have high risk of visual impairment due to presence within critical period of visual development. An essential measure for early detection of vision disorders in children involves health screening programs within school settings. Teachers can be delegated as screening officer, but their effectiveness requires comprehensive training to ensure adequate knowledge and skills. This research aims to develop a valid training module to equip Junior High School (SMP) and Senior High School (SMA) teachers in Jakarta with the necessary skills to conduct eye examinations for school children.
Method: Mixed-methods approach with an exploratory sequential design comprising two phases.  The first phase was development of the module with descriptive qualitative as the study design. It begins with collection of module content through focus group discussions (FGD), individual interviews, and literature searching. Following analysis, module draft was developed, and instrument for the second phase of research were formulated and validated. The second phase consist of contend and construct validation of the module. Conten validity assessed by validator using questionaire and was analyzed using item-level content validity index. Construct validity was determined within training of teachers at SMP 55 and SMA 31 Jakarta involving knowledge assessment (pre-test and post-test) and skills evaluation.
Results: Content of module was developed through six-stage process using information that was obtained from FGD and interviews. Result of content validity test was 1.00. A significant difference in teachers' knowledge scores was observed before and after the training (p=0.000), with 100% of participants demonstrating proficient skills in conducting examinations.
Conclusion: The training module for eye examinations in school-aged children by SMP and SMA teachers in Jakarta exhibits good content and construct validity.
"
Jakarta: Fakultas Kedokteran Universitas Indonesia, 2024
SP-pdf
UI - Tugas Akhir  Universitas Indonesia Library
cover
Christella Caroline
"Latar belakang: Pengetahuan dan perawatan lensa kontak yang baik merupakan faktor yang memengaruhi keamanan dan risiko komplikasi akibat penggunaan lensa kontak. Tujuan: Penelitian ini bertujuan untuk menghasilkan materi edukasi yang valid dan dapat digunakan sebagai standar materi edukasi bagi penjual lensa kontak sehingga informasi yang akurat dapat diberikan kepada seluruh pengguna lensa. Metode: Penelitian ini merupakan penelitian kualitatif yang terdiri dari 2 tahap, yaitu pengembangan materi edukasi dan validasi. Pengembangan materi edukasi diawali dengan tinjauan pustaka dan kesepakatan ahli melalui metode modifikasi Delphi. Item materi edukasi yang telah melalui seleksi ahli kemudian dibuat menjadi brosur, presentasi, dan checklist untuk divalidasi kepada penjual dan pengguna lensa kontak. Hasil: Item materi edukasi yang disepakati melalui metode modifikasi Delphi berjumlah 38 item materi. Nilai validasi konstruk materi edukasi adalah 3,54. Kesimpulan: Materi edukasi termasuk dalam kategori sangat valid sehingga dapat dipakai sebagai materi edukasi bagi penjual dan pengguna lensa kontak di Indonesia.

Background: The safety and risk of complications from contact lens use are influenced by factors such as proper knowledge and maintenance. Objective: To produce valid educational materials that can be used as standard educational materials for contact lens sellers in order to provide accurate information. Methods: This research is a qualitative research that consists of two stages, namely the development of educational material and validation. The development of educational materials began with a literature review and expert agreement through Delphi modification methods. Educational material that had been selected by experts were then made into brochures, presentations, and checklists for validation to the sellers and contact lens users. Results: There were 38 different educational materials that were agreed upon using the Delphi modification method. The construct validation value of the education material is 3,54. Conclusion: The educational material falls into the extremely valid category and can be utilized by Indonesian contact lens wearers and salespeople."
Jakarta: Fakultas Kedokteran Universitas Indonesia, 2024
SP-pdf
UI - Tugas Akhir  Universitas Indonesia Library