Faktor-faktor yang berhubungan dengan persepsi pekerja tentang risiko bahaya radiasi di Instalasi Radioterapi dan Radiodiagnostik Rumah Sakit Kanker Dharmais Jakarta Tahun 2006

Jajang Subagja; Robiana Modjo, supervisor (Universitas Indonesia, 2006)

 Abstrak

Instalasi Radioterapi dan Radiodiagnostik menggunakan teknologi radiasi untuk pengobatan (terapi) dan pemeriksaan (diagnostik). Penggunaan teknologi radiasi di RSKD berdasarkan data bulan Maret-Mei 2006 intensitasnya cukup tinggi 51 pasien/ hari (Linac) dan jumlah kunjungan pasien ke instalasi Radioterapi rata-rata sebanyak 1.977 orang per bulan sedangkan jumlah kunjungan ke instalasi Radiodiagnostik rata-rata sebanyak 1.031 orang per bulan.
Penggunaan teknologi radiasi tersebut bila tidak secara dini diperhatikan dan dipelihara dengan baik akan menimbulkan risiko dan bahaya seperti kecelakaan radiasi, kebocoran pesawat radiasi, kecelakaan kontaminasi, kebakaran, dan sebagainya. Faktor utama terjadinya kecelakaan radiasi adalah faktor manusia, peralatan, dan lingkungan kerja. Kecelakaan tersebut sewaktu-waktu dapat terjadi dikarenakan perilaku yang tak aman dari pekerja.
Perilaku yang tak aman tersebut dapat disebabkan oleh persepsi yang salah dalam memahami risiko dan bahaya tersebut. Penelitian ini bertujuan untuk mengetahui faktor apa saja yang berhubungan dengan persepsi pekerja tentang risiko bahaya radiasi dan faktor apa yang paling dominan dalam hubungan tersebut, selain itu jugs ingin mengetahui gambaran sistem manajemen keselamatan radiasi.
Janis penelitian ini adalah penelitian deskriptif analitik dengan desain penelitian cross sectional. Data yang diperoleh akan dilakukan analisis kualitatif dan analisis kuantitatif. Populasi penelitian ini adalah seluruh pegawai pada Instalasi Radioterapi dan Radiodiagnostik RSKD kecuali dokter. Data yang dikumpulkan berasal dari data primer dengan cara wawancara/ kuesioner dan data sekunder baik berupa data kuantitatif maupun kualitatif yang berkaitan dengan penelitian. Kemudian data tersebut diolah secara univariat (distribusi frekuensi), bivariat (analisis chi square), dan multivariat (analisis regresi logistik).
Dalam penelitian ini didapatkan hasil, sistem manajemen keselamatan radiasi di Rumah Sakit Kanker Dharmais sudah baik. Hal tersebut terlihat dari pemenuhan oleh pengusaha instalasi hal-hal yang terdapat dalam peraturan pemerintah (PP 63 tahun 2000). Persepsi pekerja tentang risiko bahaya radiasi adalah baik (57,1%). Sebagian besar pekerja memiliki persepsi yang baik terhadap kebijakan K3 (74,1%), program K3 (67,7%), kondisi peralatan (54,8%), dan media komunikasi (69,0%).
Faktor-faktor internal pekerja yang berhubungan dengan persepsi pekerja tentang risiko bahaya radiasi adalah pengetahuan dan jenis pekerjaan dan yang paling dominan berhubungan adalah jenis pekerjaan. Sedangkan faktor-faktor eksternal pekerja yang berhubungan dengan persepsi pekerja tentang risiko bahaya radiasi adalah kebijakan K3, program K3 dan media komunikasi (p value < 0,05) dan yang paling dominan berhubungan adalah kebijakan K3.
Dengan demikian, perlu adanya peningkatan kuantitas dan kualitas pelaksanaan program dan monitoring dengan melakukan penjadwalan program secara rutin, seperti promosi kesehatan pekerja, pendidikan dan pelatihan, pemeriksaan kesehatan, pengukuran dan pemantauan radiasi. Perlunya peran serta pekerja dalam setiap pelaksanaan program proteksi radiasi serta kepatuhan dan kesadaran pekerja urituk menggunakan alat pemantau radiasi perorangan.

Radiotherapy and Radiodiagnostic installation uses radiation technology for therapy and diagnostic. Utilization of radiation technology in RSKD was quite highly around 15 patientlday during March-May 2006. Number of patient visit to radiotherapy installation is 1.977 patients per month, while number of visit to Radiodiagnostic installation is 1.031 patients per month.
We need to put well attention toward utilization of those radiation technologies and maintain it to minimize risk and hazard radiation such as radiation accident, radiation equipment leak, contamination accident, burned. Main factors of radiation accidents occurrence are human, equipment, and working environment. Those accidents could occur at any times because of unsafe behavior from workers.
Those unsafe behaviors could be caused by wrong perception in understanding those risk and hazards. This research aim is to know factors that related with worker perception toward radiation risk and to assess a dominant factor in those relations as well as to know the portrait of radiation safety management system.
This research was an analytic descriptive research using cross sectional research design. Gathered data were analyzed using qualitative and quantitative approach.
Population study was all employees at Radiotherapy and Radiodiagnostic Installation of RSKD except doctor. Data were collected using questionnaire and observation of documents related.
This study found radiation safety management system in Dharmais Cancer Hospital is good enough based on fulfillment the government regulation (PP 63 Year 2003) by entrepreneur of installation. Proportion of workers who have good perception on radiation hazard risk is 57.1%. Most workers have good perception toward OSH (occupational safety and health) policy (74,1%), condition of equipment (54,8%), and communication media (69,0%),
Internal factors of workers that related to worker perception toward radiation hazard risk are knowledge and work type. The most dominant factor is work type. Meanwhile, external factors of workers that related to working perception toward radiation risk is OSH policy, OSH program, and communication media. The most dominant of external factor is perception on OSH policy.
Therefore, RSKD should improve whether quantity or quality of program such as worker health promotion, education and training, health screening, measuring and monitoring of radiation. RSKD also should monitor those programs routinely. Workers should involve in radiation protection program as well as comply to use personal radiation monitoring device.

 File Digital: 1

Shelf
 T 18994a.pdf :: Unduh

LOGIN required

 Metadata

No. Panggil : T18994
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Subjek :
Penerbitan : Depok: Universitas Indonesia, 2006
Program Studi :
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : unmediated ; computer
Tipe Carrier : volume ; online resource
Deskripsi Fisik :
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
No. Panggil No. Barkod Ketersediaan
T18994 15-20-929944187 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 106887