Keberhasilan pemasangan sungkup laring proseal: perbandingan penggunaan rokuronium dosis 0.2 mg/kg bb dengan rokuronium dosis 0.1 mg/kg bb

Setyadi; Indro Mulyono, supervisor; Sudarsono, supervisor (Fakultas Kedokteran Universitas Indonesia, 2006)

 Abstrak

Tujuan: Membandingkan angka keberhasilan dan kemudahan pemasangan sungkup faring proseal (LMP) yang difasilitasi rokuroniun dosis 0,2 mg/kg bb dengan rokuronium dosis 0.1 mg/kg bb.
Metode: Dilakukan uji klinik tersamar ganda pada 48 pasien yang menjalani operasi berencana dengan anesthesia umum. Pasien dibagi menjadi 2 kelompok, yaitu 24 pasien mendapat rokuronium dosis 0,2 mg/kg bb dan 24 pasien lainnya mendapat rokuronium dosis 0,1 mg/kg bb untuk memudahkan pemasangan LMP. Selama penelitian, dilakukan pengamatan frekuensi dan kemudahan upaya pemasangan serta perubahan hemodinamik. Data numerik akan dianalisis dengan uji t serta data nominal dengan uji x-kuadrat dan uji Fisher.
Hasil: Tidak ditemukan perbedaan berrnakna pada angka keberhasilan dan kemudahan pemasangan LMP antara kelompok yang mendapatkan rokuronium dosis 0,2 mg/kg bb dengan rokuronium 0,1 mg/kg bb. lnsiden gerakan, batuk dan relaksasi mandibula tidak berbeda bermakna. Satu kasus dari kelompok yang mendapatkan rokuronium dosis 0,1 mg/kg bb gagal dipasang dan mengalami laringospasme.
Kesimpulan: Pemberian rokuronium dosis 0,2 mg/kg bb mempunyai angka keberhasilan dan tingkat kemudahan yang sama dalam pemasangan LMP dengan rokuronium dosis 0,1 mg/kg bb.

Purpose: To compare success rate and ease grade on LMP insertion facilitated with rocuronium 0.2 mg/kgBW with rocuronium 0.1 mg/kgBW.
Methods: We performed a randomized, double-blind study in 48 patients under general anesthesia. Patients were randomized into two groups; 24 patients had rocuronium 0.1 mg/kgBW and others had rocuronium 0.2 mg/kgBW to facilitated LMP insertion. During the research, we observed the success rate and ease grade and also haemodynamic changes. For statistical analysis we used t-test, chi-square test and Fisher's test.
Results: There were no differences in patients who had rocuronium 0.1 mglkgBW and rocuronium 0.2 mg/kgBW to facilitated LMP insertion for success and ease grade. There were no significance in movement incidences; cough and mandibula relaxation. There is one patient from rocuronium 0.1 mg/kgBW group that failed because of laryngospasm.
Conclusion: LMP insertion with rocuronium 0.1 mg/kgBW and rocuronium 0.2 mg/kgBW have the same success rate and ease grade.

 File Digital: 1

Shelf
 T-pdf-Keberhasilan pemasangan - Full text.pdf :: Unduh

LOGIN required

 Metadata

No. Panggil : T-Pdf
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Subjek :
Penerbitan : Jakarta: Fakultas Kedokteran Universitas Indonesia, 2006
Program Studi :
Bahasa : ind
Sumber Pengatalogan :
Tipe Konten :
Tipe Media :
Tipe Carrier :
Deskripsi Fisik :
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
No. Panggil No. Barkod Ketersediaan
T-Pdf 15-20-420023643 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 110386