Merujuk pada ketentuan ILO (International Labour Organizations) yang menyatakan bahwa industri pupuk termasuk ke dalam kategori industri dengan major hazard (kebakaran, ledakan dan kebocoran bahan kimia berbahaya). Skripsi ini membahas tentang potensi terjadinya ledakan pada pipa gas hidrogen yang disebabkan oleh pelepasan gas hidrogen ke udara dan memproyeksikan area kerusakan (threat zone) akibat ledakan jika terjadi ledakan pada pipa tersebut. Penelitian ini merupakan penelitian kuantitatif dengan disain deskriptif yang menggunakan teknik event tree analysis (ETA) dan piranti lunak ALOHA (Area Locations of Hazardous Atmosphere).
Hasil penelitian menunjukkan bahwa terlepasnya gas hidrogen dapat menyebabkan jet fire, flash fire, kebocoran gas beracun dan vapor cloud explosion, tergantung pada jumlah material hidrogen yang terlepas, kecukupan bercampur dengan udara dan penundaan ignisi. Proyeksi area kerusakan (threat zone) menunjukkan bahwa area merah, yaitu area yang dapat menghancurkan bangunan dan menyebabkan kematian, berada dalam radius 214 meter dengan luas area sebesar 143.930 m2. Area oranye, yaitu area yang dapat menyebabkan cedera serius, berada dalam radius 244 meter dengan luas area sebesar 187.113 m2. Area kuning memiliki radius terjauh ledakan yaitu sebesar 407 meter dengan luas area berisiko sekitar 520.611 m2.
Perkiraan jumlah korban akibat ledakan ini adalah sekitar 500 orang, sebagian besar diantaranya merupakan karyawan yang bekerja di pabrik. Orang yang berisiko menjadi korban adalah mereka yang berada dalam area kuning ketika ledakan tersebut terjadi. Untuk itu, peneliti menyarankan agar PT Pupuk Kujang Cikampek meningkatkan kualitas dan kuantitas alat detektor hidrogen, membuat sistem peringatan dini, mengadakan pelatihan penanganan kebocoran bahan kimia dan meletakkan alat pemadam kebakaran lebih dekat dengan area yang kaya akan gas flammable.
According to the ILO (International Labor Organizations) rule that a fertilizer company is included into the category of a major hazard industry which contains probability of fire, explosions and toxic gas released. This paper analysis about potency of explosion happenings in hydrogen gas pipes which is caused by hydrogen gas released to the air and describes threat zone because of several explosions in its pipes. This paper is a quantitative studies with descriptive design study which uses ETA (event tree analysis) technique and ALOHA (Area Locations of Hazardous Atmospheres) software.
This studies shows that hydrogen gas released to the air can cause several outcomes, like jet fire, flash fire, toxic gas released and vapor cloud explosion depending on quantity of hydrogen released, sufficiency of mixed air volume and delayed ignition. Projection of each threat zone area caused by explosion shows that red zones is 143.930 m2 in 214 m from the centre of the explosions that can destroy several buildings and potentially most caused death. Orange area is 187.113 m2 in 244 m from the centre of the explosions which can cause serious injuries. Yellow area is 520.611 m2 in 407 m out of its threat zone. The estimation about the victims of this explosion is 500 persons that most of them are the employee who works in plant. People at risk which can be a victim of it is they who is in yellow areas when the explosion was happened.
Therefore, author suggests that PT Pupuk Kujang Cikampek has to increase the quality and the quantity of hydrogen detector tools, make an early alarm system, conduct toxic material release training and provide fire extinguisher in the position that very close with the flammable gas areas.

 Metadata

No. Panggil : S-Pdf
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Subjek :
Penerbitan : Depok: Universitas Indonesia, 2009
Program Studi :
Bahasa : ind
Sumber Pengatalogan :
Tipe Konten :
Tipe Media :
Tipe Carrier :
Deskripsi Fisik : xiv, 110 lembar.: il; 29 cm.
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
No. Panggil No. Barkod Ketersediaan
S-Pdf 14-17-509199318 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 126260