Penentuan karakteristik kuat kerma dan konstanta laju dosis sumber Ir-192 mHDR menggunakan metode monte carlo dan eksperimen = Measurement of Ir-192 mHDR's air-kerma strength and dose rate constant characteristic using monte carlo method and experiment

Siti Aisah; Dwi Seno Kuncoro Sihono, supervisor; Sugiyantari, supervisor (Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2010)

 Abstrak

Telah dilakukan pengukuran karakteristik dosimetri sumber Ir-1 92 microselectr0nHDR (mHDR) brakiterapi menggunakan metode Monte Carlo dan eksperimen. Untuk simulasi Monte Carlo digunakan program EGSnrc dengan medium vacum, udara dan air . Untuk eksperimen dilakukan dengan metode “in-air measurement dalam medium udara menggunakan jig, elektrometer Keithley 6487, NE 2571 Fanner chamber dan sumber Ir-192 dengan aktivitas yang terukur 4557 mCi. Dari simulasi, pengukuran kuat kenna per aktivitas rata-rata dalam medium vacum adalah 8.21.10-8 U Bq-1, di udara 8.2.10-8 U Bq-1 dan di air 8.48.10-8 U Bq-1 . Umuk konstanta laju dosis, nilai yang diperoleh adalah 2,79.10-6 Gy s-1 U-1 di vacum, 2,79.10-6 Gy s-1 U-1 di udara dan 3,18.10-6 Gy s-1 U-1 di air. Kuat kenna per aktivitas di udara pada jarak 10 cm yang diperoleh dari simulasi 8,18.10-8 U Bq-1, bila dibandingkan dengan kuat kenna per aktivitas di udara pada jarak yang sama dalam protokol (PIRS-629r) yaitu 9,709.10-8 U Bq-1 memiliki deviasi sebesar 15,73%.
Dari eksperimen, hasil pengukuran kuat kenna per aktivitas di udara pada jarak 10 cm adalah 0,001.10-8 U Bq-1 dan kuat kenna per aktivitas di udara pada simulasi adalah 8,18.10-8 U Bq-1, perbedaan yang cukup besar dapat disebabkan karena aktivitas yang dimaksudkan dalam PIRS-629r adalah aktivitas pada sumber, bukan aktivitas yang terukur. Pada kuat kerma per aktivitas di air menunjukkan bahwa jarak efektif pemberian dosis brakiterapi pada jaringan tubuh adalah kurang dari 5,5 cm atau sekitar 5cm.

Measurement on lr-192 mHDR V2 brachytherapy source's dosimetry characteristic were done using Monte Carlo method and experiment. The Monte Carlo simulation Were done in vacum, air and Water us ing EGSnrc software. The experiment were done by using “in-air measurement” method Which equipment consist of jig, electnometer Keithley 6487, NE 2571 Farmer chamber and Ir-192 source with 4557 mCi of apparent activity. The average of air-kerma strength per unit activity in simulation result is 8.2.10 -8 U Bq -1 in vacum, 8.2.10 -8 U Bq-1 in air and 8.48.10 -8 U Bq -1 in water. Dose rate constant in vacum is 2,79.10 -6Gy s-1 U-1, 2,79.10 -6Gy s-1 U-1 in air and 8,18.10 -6 Gy s-1 U-1 in Water. Air-kerma strength per unit activity at 10 cm in air calculation is 8,18. 10-8 U Bq-1 di vacum, comparing to the air- kerma strength per unit activity at the same distance in air based on protocol (PIRS-629r) 9,709. 10-8 U Bq-1, the deviation is 15,73%.
From experiment calculation, the air-kerma strength per unit activity at 10 cm in air is 0,001. 10-8 U Bq-1 and simulation's result is 8,18. 10-8U Bq-1, this large difference may be caused of activity based on PIRS-629r is the real activity of the source, not the apperent activity. The air-kerma strength per unit activity in water shows the effective distance for tissue in brachytherapy treatment is less than 5,5 cm or about 5 cm.

 File Digital: 1

 Metadata

No. Panggil : S29455
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Subjek :
Penerbitan : Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2010
Program Studi :
Bahasa : ind
Sumber Pengatalogan :
Tipe Konten :
Tipe Media :
Tipe Carrier :
Deskripsi Fisik : xiii, 41 hlm. : ill. ; 28 cm. + lamp.
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
No. Panggil No. Barkod Ketersediaan
S29455 14-21-34798926 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20181614