:: UI - Skripsi Membership :: Kembali

UI - Skripsi Membership :: Kembali

Rekalkulasi beban pendinginan dan dimensi ducting pada ruang teater gedung X

Asep Hidayatullah; Rusdy Malin, supervisor ([Publisher not identified] , 2000)

 Abstrak

Fungsiutama dari pengkondlsian udara adalah untuk menjaga kondlsi ruangan agar tetap nyaman bagi manusia. Untuk menjalaokan fungsi tersebut maka peralatan harus dipasang untuK menjaga kondisi ruangan. Kapasnas peralatan ditentukan oleh kebutuhan beban puncak aktual. Sebelum beban pendinginan dihttung dilakukan terlebih dahulu dllakukan survel secara menyeluruh untuk menjamin keakuratan perhitungan dari komponen-komponen beban.
Dalam sutvel gedung membutuhkan gambar mekanlkal, arsitek untuk mengetahui kondisi fisik bangunan, material bangunan, ukuran fisik bangunan, material bangunan, ceiling space, kondisi seke!111ngnya dan lain-lain. Karenanya koordinasi antara perencana mekanikal merupakan suatu keharusan. Perhitungan beban pendinginan menggunakan form yang didesain secara sistematis untuk mengidentifikasi tipe beban yang terjadi. Tipe beban terrliri dari beban dari luar dan dalam, keduanya bisa beroentuk sensible dan latent. Beban e1Total beban pendinginan yang merupakan akumulasi panas internal dan eksternal ditambah factor keasaman adalah grand total heat (GTH).

Primary function of air cnditioning is to maintain condrtions of room to human comfort. To perform thfs function, equipment must be installed to maintain conditions of room. The equipment capacfty is determined by actual peak load requirement. Before the load can be estimated it is imperative that a comprehensive survey be made to assure accurete evaluation of the load components. Building survey mus1 be do to get accuracy of load components.
In building survey we need mechanicaland architectural drawing to determine physical conditions of building like orientation of building, oeiling space, sorrounding conditions, therefore coordination beetwen mechanical, architect and eiecttical
engineer is a must.
Cooling load calculation use fonn which designed systematically to identify type of load. Type of load consists of external and internal load, both can be sensible and or latent heat External load for examples solar radiation, temperature difference beetwen unconditioned and condiTioned room, internal heat consists of heat from human, lights, equipment etc. Heat transfer according to formula a u X A X t\T can be calculated base on data from drawing. Total cooling load that accumulative of intemal and external heat plus safety factor is named Grand Total Heat (GTH). After cooling load calculation, we calculate

 File Digital: 1

Shelf
 S-Asep Hidayatullah.pdf :: Unduh

LOGIN required

 Metadata

No. Panggil : S37212
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Subjek :
Penerbitan : [Place of publication not identified]: [Publisher not identified], 2000
Program Studi :
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : unmediated ; computer
Tipe Carrier : volume ; online resource
Deskripsi Fisik : xi, 68 pages : illustration ; 28 cm. + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
No. Panggil No. Barkod Ketersediaan
S37212 14-19-931260667 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20241095