:: UI - Skripsi Membership :: Kembali

UI - Skripsi Membership :: Kembali

Pencegahan kegagalan proses pada injection molding machine dengan metode fmea (studi kasus: clamping dan locking

Taufiq Ismail; Bambang P. Prianto, supervisor (Fakultas Teknik Universitas Indonesia, 2006)

 Abstrak

Seiring dengan semakin berkembangnya teknologi manufaktur, maka penggunaan material Plastik juga semakin beragam. Dan pada saat ini sebagian besar industri manufaklur mcnggunakan komponen terbuat dari material plastik, termasuk industri elelctronika dan automotif.
Untuk menghasilkan produk plastik yang baik dengan jumlah yang relatif banyak dzlam waktu yang cepat, diperlulcan mesin Plastic Iryection Molding yang dapat dioperasikan secara maksimal dan optimal.
Pada saat siklus produksi berlangsung, ada kalanya teriadi kegagalan baik produk maupun proses. Salah satu kegagalan proses pada mcsin Plastic Injection Molding adalah kcgagalun Clamping dan Locking. Kegagalan proscs Clamping dan Locking memerlukan waktu yang relatif lama dalarn melakukan tindakan troubleshooting atau perbaikan, yaitu antara I0 mcnit sampai 10 jam. Kalau kegagalan ini sering tcrjadi maka akan sangat mengganggu proses produksi.
Penerapan metode FMEA (Failure Mode, Eject, and Anabfsis) pada prosos Clamping dan Locking dapat digunakan untuk mengurangi kemungkinan terjadinya kegagalan proses dengan cara menentukan semua potensi kegagalan (potential failure ntorle) misalnya kcgagulnn pada proscs hydraulic system worked, akibal kegagalannya (potential ejects of failure) yaitu moving platen tidak dapat bcrgcruk, nilai kcseriusan akibat kegagalan (severity) adalah 8.
Langkah selanjutnya mcnentukan polensi penyebab kegagalan (potential causes offailure) yaitu control circuit kotor, panas, atau rusak, kemudian frelcuensi tcrjadinya penyebab kegagalan dinmgking dengan menentukan nilai occurrence, yaitu 2. Setelah itu ditentukan lcontrol aliran proses (current process control) untuk mendeteksi teijadinya penyebab kegagalan yaitu alarm dan tampilan pads monitor control kemudian kcmampuan penyebab kegagalan dapat dideteksi (detection) dibcri nilai S, sehingga diperoleh nilai prioritas resiko alau risk priority number {Rl’N=S.O.D) udalab 80.
Selanjutnya ditentukan langkah penanganan kegagalan (recommended actions) dan pelaksanaannya (actions taken) yaitu pengecekan dan pembersihan control circuit setiap bulan dan perbaikan kerusakan schingga potensi penyebab terjadinya kcgagalnn berkurang, ditandai dengan menurunnya nilai RPN. Paula potousl pany;-bob kogagnlnn control elrcult Rotor. penal. atau rusak nilai RPN menurun dari 80 menjadi 48.
Dengan FMEA dapnt dirancang suatu program preventive maintenance untuk IIICIICCBIIII lcrjndinyu kcgngnlun proxcs (.'lampirtg dun Locking pudu siklus produksi l’ln.vtic Ingestion Molding Machine. Unluk mcncegah tcrjadinya potensi penyebab kegagalan control circuit kotor, pnnas, atau rusak adalah clengan pelaksanaan maintenance procedure pengccekan visual, pcngcccknn dengan multitester, pembersihan, perbaikau kerusakan, dan memastilmn fan pendingin berfungsi, dengan waktu pelaksanaan setiap bulan.

Follow to the development of manufacttue technologies, the use of plastic are so variously. Now, there are many manufacture industries that use the component or part from plastics, especially in electronics and automotive industries.
For producing the good quality plastic products with good quantity on a short time, need The Plastic Injection Molding Machine that can operate maximally and optimally.
On the production cycle, sometime the failure in product and process is happened. One of process failure on the Plastic Injection Molding Process is “Clamping and Locking Failure". This failure need a long time of service, repair or troubleshooting (its about 10 minutes - 10 hours). lf this failure oiien happened, its will disturb the production process.
Failure Mode and Effect Analysis (FMEA) in Clamping and Locking process will eliminate or reduce the failure happened by evaluate all of potential process failure (potential failure mode), ex: failure in hydraulic system worked, evaluate the potential effect of failure, moving platen can’t move then give the assessment ofthe effect (severity). In this case, the severity is 8.
Evaluate the potential causes of failure, it’s the control circuit dirty, high temperature, or break. Then assess the occurrence of potential causes happened. The occurrence is 2. Then develop the current process control to detect the cause of failure happened. It’s control by alarm and statement on control monitor. Then assess the ability of process control can detect the failure. The detection is S. After the step above the Risk Priority Number (RPN) will be found, it’s 80.
Then develop the recommended action and action taken. In this case, it’s checking and cleaning the control circuit every month and repair if any troubles. The potential cause of failure will reduced. It’s indicate by the decrease of RPN from 80 to 48.
The result of FMEA implementation is the preventive maintenance program to avoid, eliminate, or decrease the potential failure in Clamping and Locking Process on the Plastic Injection Molding Process. To prevent the potential cause of failure happened, ex: control circuit dirty, high temperature, or break by take the maintenance procedure action like visual checking, multi tester checking, cleaning, repairing, and ensure that the cooling fan worked. lt’s procedure must be taken every month.

 File Digital: 1

Shelf
 S37545-Taufiq Ismail.pdf :: Unduh

LOGIN required

 Metadata

No. Panggil : S37545
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Subjek :
Penerbitan : Depok: Fakultas Teknik Universitas Indonesia, 2006
Program Studi :
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : unmediated ; computer
Tipe Carrier : volume ; online resource
Deskripsi Fisik : xii, 168 pages : illustration ; 28 cm + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
No. Panggil No. Barkod Ketersediaan
S37545 14-22-96361966 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20241810