Evaluasi kinerja sitem proteksi katodik metode anoda korban pada jalur pipa yang dibenamkan di dalam tanah daerah Tambu - Cimalaya dan Cemara - Balongan Jawa Barat = Evaluation of performance sacrifical anode cathodic protection system in pipeline buried at Tambun-Cimalaya and Cemara-Balongan (West Java)

Mukhkhinur; Andi Rustandi, supervisor (Fakultas Teknik Universitas Indonesia, 2009)

 Abstrak

Jalur pipa (pipeline) minyak mentah yang dibenamkan didalam tanah dengan menggunkan sistem proteksi katodik dengan metode Sacrifial Anode (anoda korban) haruslah dimonitoring. Monitoring dapat dilakukan dengan dengan metode CIPS (Close Interval Potensial Survey) dan DCVG (Dirrect Current Voltage Gradient). Hasil survey CIPS digunakan untuk memantau apakah struktur berada dalam kriteria proteksi dengan mengacu pada NACE standard- RP 0169-2002. DCVG digunakan unttuk memastikan penyebab tidak terproteksinya struktur apakah dikarenakan cacat coating atau tidak berfungsinya sistem proteksi katodik. Pada jalur pipa Cemara- Balongan di kilometer (km) ke 1-7, 12-14, 16-17, 19-24, 25-27 (kecuali 3 m mendekati Test Point) dan km ke 28 dan 24% Test Point ditemukan dalam keadaan baik. Pada km ke 4-5 (meter ke 600-750) memiliki potensial berkisar -0,45 V sampai dengan -0,775 V dan km 9-10 (600 meter menuju TP-10) dengan potensial berkisar - 0,270 V sampai dengan -0,800 V. Sedangkan pada jalur pipa Tambun-Cilamya, sistem poteksi katodik secara keseluruhan mengalami over protection dengan potensial berkisar -1,1 V sampai dengan -1,6 V. Oleh karena itu perlu adanya perbaikan terhadap sistem proteksi pada jalur ini karena menyebabkan disbonding coating.

Crude Oil Pipeline in Underground using Sacrificial Anode Cathodic Protection System have to be monitored. It can be be done by CIPS (Close Interval Potensial Survey) and DCVG (Direct Current Voltage Gradient) methods. Result survey of CIPS used to evaluation whether pipeline include criteria protection reference to NACE Standard 'RP 0169-2002. DCVG used to ensure whether a cause of unprotected structure because of coating defect or dysfunctional systems.In Cemara- Balongan Pipeline, at kilometer (km) of 1-7, 12-14, 16-17, 19-24, 25-27 (except 3 m closed to Test Point) and km of 28 (except 100 m closed to TP 57) or as long ad 21,641 m (77,28%) structure unprotected and 24% of test point found in good condition. In km of 4-5 (meter of 600-750) have potensial in range -0,45 V to -0,775 V and km of 9-10 (600 closed to TP 10) in range -0,270 to 0,800 V. So, in these location prefer to be renovaton of its cathodic protection system. In Tambun- Cilamaya Pipeline, Generally, overall of cathodic protection system is overprotection in range -1,1 to -1,6 V potensial reduction. Therefore, it is have to be repair because it can bring about of disbonding coating.

 File Digital: 1

 Metadata

No. Panggil : S51118
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Penerbitan : Depok: Fakultas Teknik Universitas Indonesia, 2009
Program Studi :
Bahasa : ind
Sumber Pengatalogan :
Tipe Konten :
Tipe Media :
Tipe Carrier :
Deskripsi Fisik : xiii, 69 hlm. ; ill. ; 30 cm. + lamp.
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
No. Panggil No. Barkod Ketersediaan
S51118 14-22-91327852 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20249351