Perbandingan koefisien perpindahan kalor dengan menggunakan beberapa korelasi untuk aliran evaporasi dua fasa pada kanal mini horizontal dengan refrigeran R-22 = Comparison of heat transfer coefficient using some correlations for two-phase flow boiling in horizontal minichannel with R-22
Yudha Syafei Agustian;
Agus Sunjarianto Pamitran, supervisor; Engkos Achmad Kosasih, examiner; Nasruddin, examiner; Ardiansyah, examiner
(Fakultas Teknik Universitas Indonesia, 2011)
|
ABSTRAK Penelitian ini membahas tentang perbandingan koefisien perpindahan kalor alirandua fasa dari hasil percobaan dengan hasil prediksi dari korelasi yang terdapatpada literatur. Percobaan dilakukan pada kondisi perpindahan panas konveksididih pada kanal mini horizontal dengan refrigeran R-22. Test section terbuat daripipa stainless steel dengan diameter dalam 3 mm, panjang 1000 mm dandipanaskan secara merata di sepanjang pipa tersebut dengan heat flux divariasikanantara 5 kW/m2 sampai dengan 15 kW/m2. Dalam penelitian ini menggunakankorelasi Chen (1963), korelasi Gungor-Winterton (1986) dan korelsi Zhang et al.(2004). Selanjutnya koefisien perpindahan kalor dari tiap korelasi dihitung dandibandingkan mean deviation dan average deviation-nya terhadap hasil percobaanuntuk mengetahui penyimpangan pada setiap korelasi. Koefisien perpindahankalor yang diperoleh dengan menggunakan korelasi Chen memiliki mean danaverage deviaion lebih rendah dibandingkan dengan korelasi lain. Nilai koefisienperpindahan kalor dipengaruhi oleh heat flux yang diberikan, dimana semakinbesar heat flux yang diberikan maka semakin besar pula nilai koefisienperpindahan kalornya. ABSTRACT This study discusses the comparison of two phase flow heat transfer coefficient ofthe experimental results with predicted results from the correlation found in theliterature. Experiments were performed on the convective boiling heat transfer inhorizontal minichannel with R-22. The test section was made of stainless steeltube with inner diameter of 3 mm, length of 1000 mm and it is uniformly heatedalong the tube with heat flux was varied from 5 kW/m2 up to 15 kW/m2. In thisstudi using Chen?s correlation (1963), Gungor-Winterton?s correlation (1986) andZhang?s correlation (2004). Furthermore, the heat transfer coefficient from eachcorrelation was calculated and compared with the mean deviation and averagedeviation of the experimental results to determine deviations in each correlations.Heat transfer coefficients obtained by using Chen?s correlation has a mean andaverage deviation lower than other correlations. The value of heat transfercoefficient is affected by the heat flux was given, where the higher value of heatflux given will result the higher value of heat transfer coefficient. |
S1798-Perbandingan koefisien.pdf :: Unduh
|
No. Panggil : | S1798 |
Entri utama-Nama orang : | |
Entri tambahan-Nama orang : | |
Entri tambahan-Nama badan : | |
Subjek : | |
Penerbitan : | [Place of publication not identified]: Fakultas Teknik Universitas Indonesia, 2011 |
Program Studi : |
Bahasa : | ind |
Sumber Pengatalogan : | LibUI ind rda |
Tipe Konten : | text |
Tipe Media : | unmediated ; computer |
Tipe Carrier : | volume ; online resources |
Deskripsi Fisik : | xiv, 70 pages ; 30 cm |