Eksperimental dan permodelan karakteristik distribusi kabut air dua nosel untuk aplikasi pemadaman kebakaran kolam api = Eksperimental and modeling study of the distibution characteristic of two water mist nozzles for fire extinguishment of pool fire
Hendar Kusnandar;
Yulianto Sulistyo Nugroho, supervisor; Engkos Achmad Kosasih, examiner; Harinaldi, examiner; I Made Kartika Dhiputra, examiner; Warjito, examiner
(Fakultas Teknik Universitas Indonesia, 2012)
|
ABSTRAK Popularitas water mist saat ini semakin meningkat untuk berbagai aplikasikhususnya dalam bidang proteksi kebakaran dan pendinginan permukaan bahanbakar. Penelitian ini berfokus studi eksperimen dan permodelan dari karakteristikwater mist dan pemadaman kebakaran jenis pool fire untuk sebuah nosel daninteraksi dari dua nosel pada variasi jarak yang ditentukan. Full-cone noseldioperasikan pada tekanan yang bervariasi dengan volume diameter droplet rataratadiharapkan 110 um. Karakteristik dari spray water mist didefinisikan denganmenggunakan derajat keabu-abuan (gray level) pada daerah tertentu. Pengukuranmenunjukkan bahwa panjang diameter spray atau coverage area lebih besardicapai pada tekanan yang lebih besar. Dalam kasus interaksi dua nosel, interaksipenggabungan spray yang seragam dihasilkan pada jarak yang lebih pendek dariujung nosel pada tekanan lebih tinggi. Hasil eksperimental dan simulasimenunjukan bahwa efektiitas pemadaman kebakaran pool fire bergantung padaposisi nosel, jumlah nosel, momentum yang diberikan. Sebuah teknik pengukuranyang sederhana telah dikembangkan dalam pekerjaan ini. AbstractPopularity of water mist is rising for a variety of applications, especially inthe field of fire protection and cooling surface fuel. This study focuses toexperimental and modeling of the characteristics and water mist fire suppressionfor pool fire of a nozlle and the interaction of two nozzle variations of a defineddistance. Full-cone nozzle is operated at a pressure that varies with the volumeaverage droplet diameter of 110 um is expected. Characteristics of a water spraymist is defined by using gray level in certain areas. Measurements showed that thelength of the diameter of spray or a larger coverage area is achieved at greaterpressure. In the case of two-nozzle interaction, the interaction of a uniform patternresulting in a shorter distance from the nozzle tip at higher pressure. Experimentaland simulation results show that effectiveness pool fire suppression depends onthe nozzle, number of nozzle, the momentum is given. A simple measurementtechnique has been developed in this work. |
|
No. Panggil : | T30163 |
Entri utama-Nama orang : | |
Entri tambahan-Nama orang : | |
Entri tambahan-Nama badan : | |
Subjek : | |
Penerbitan : | [Place of publication not identified]: Fakultas Teknik Universitas Indonesia, 2012 |
Program Studi : |
Bahasa : | ind |
Sumber Pengatalogan : | LibUI ind rda |
Tipe Konten : | text |
Tipe Media : | unmediated ; computer |
Tipe Carrier : | volume ; online resource |
Deskripsi Fisik : | xix, 101 hlm : Illustration : 28 cm + appendix. |
Naskah Ringkas : | |
Lembaga Pemilik : | Universitas Indonesia |
Lokasi : | Perpustakaan UI, Lantai 3 |
No. Panggil | No. Barkod | Ketersediaan |
---|---|---|
T30163 | 15-18-390359689 | TERSEDIA |
Ulasan: |
Tidak ada ulasan pada koleksi ini: 20297447 |