:: UI - Skripsi Open :: Kembali

UI - Skripsi Open :: Kembali

Perbandingan tiga metode penentuan sistem ganda dari struktur portal - dinding geser akibat beban gempa = Comparation of three methods of shear wall - frame structure as dual system subject to seismic load

Achmad Damar Al Chamid; Yuskar Lase, supervisor; Mulia Orientilize, examiner; Josia Irwan Rastandi, examiner (Fakultas Teknik Universitas Indonesia, 2012)

 Abstrak

Penelitian ini membahas mengenai metode desain sistem ganda dari struktur portal - dinding geser beton bertulang akibat beban gempa dan kebutuhan tulangan yang diperlukan untuk masing-masing metode perhitungan. Dalam penentuan sistem ganda sesuai peraturan SNI 03-1726-2002, pada penelitian ini dilakukan tiga metode desain, struktur portal - dinding geser yang berinteraksi, struktur portal dengan boundary element dinding geser, dan struktur portal dengan dengan dinding geser yang di non-aktifkan. Dalam metode portal - dinding geser yang berinteraksi, struktur bangunan di desain berdasarkan analisis dinamik dan analisis statik, tetapi untuk dua metode lainnya dilakukan dengan analisis statik.
Pada penelitian ini ditinjau bangunan 8 lantai pada lokasi gempa di Jakarta dengan tanah lunak dianalisis sebagai sistem ganda. Simulasi numerik menunjukkan bahwa pendekatan portal ? dinding geser saling berinteraksi dengan faktor reduksi R = 6,5 (SRPMM) menghasilkan tulangan paling besar dibandingkan dengan dua metode lainnya.

This thesis discussed about method of design of a reinforced concrete shear wall - frame structure as dual system due to earthquake load and the requirement of rebar for each methods. In determining dual system structure based on SNI 03-1726-2002, some methods of design such as interaction of shear wall - frame structure, frame with boundary element, and frame with deactivated shear wall is considered in this thesis. In interaction of shear wall - frame structure method, building structure was designed based on dynamic and static analysis, however for two other methods static approach was employed.
In this thesis an 8-story building located in Jakarta and built on soft soil was analyzed as dual system. Numerical simulations show that interaction of shear wall ? frame structure approach with reduction factor R = 6,5 (IMRF) results the biggest required rebar compared with other methods.

 File Digital: 1

 Metadata

No. Panggil : S43568
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Subjek :
Penerbitan : Depok: Fakultas Teknik Universitas Indonesia, 2012
Program Studi :
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : unmediated ; computer
Tipe Carrier : volume ; online resource
Deskripsi Fisik : xii, 64 pages ; 30 cm
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
No. Panggil No. Barkod Ketersediaan
S43568 14-17-381712087 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20312588