:: UI - Skripsi Open :: Kembali

UI - Skripsi Open :: Kembali

Konsentrasi PM2,5 di udara dalam ruang dan penurunan fungsi Paru pada orang dewasa di sekitar kawasan industri Pulo Gadung Jakarta Timur 2012 = Indoor PM2,5 concentration and the decline of adult lung function in the surrounding of Pulo Gadung Industries, East Jakarta 2012

Eky Pramitha Dwi Putri; R. Budi Haryanto, supervisor; Sri Tjahjani Budi Utami, examiner; Heny D. Mayawati, examiner (Fakultas Kesehatan Masyarakat Universitas Indonesia, 2012)

 Abstrak

PM2,5 adalah indikator penting untuk mengetahui risiko kesehatan yang disebabkan oleh polusi partikulat. Pajanan konsentrasi PM2,5 di udara dalam ruang telah banyak dikaitkan dengan kejadian penurunan fungsi paru. Oleh karena itu, program intervensi harus dimulai dari faktor lingkungan.
Tujuan utama dalam penelitian ini adalah untuk mengetahui hubungan antara konsentrasi PM2,5 di udara dalam ruang dengan penurunan fungsi paru pada orang dewasa. Studi potong lintang dilakukan di sekitar kawasan industri Pulo Gadung, Jakarta Timur.
Penelitian dilakukan dari bulan maret sampai mei 2012. Peneliti memilih secara acak 109 orang dewasa yang berusia 20-65 tahun dengan menggunakan metode statifikasi acak sampel. Hal ini dilakukan untuk menentukan kejadian penurunan fungsi paru dan hubungannya dengan konsentrasi PM2,5 di udara dalam ruang. Fungsi paru diperiksa dengan menggunakan spirometri tes untuk mendapatkan nilai VC, FCV, FEV1, dan FEV1/FCV. Konsentrasi PM2,5 di udara dalam ruang diukur dengan menggunakan alat dust track. Setelah itu, analisis dilakukan dengan menggunakan model regresi logistik untuk mendapatkan nilai OR dari konsentrasi PM2,5 di udara dalam ruang dengan penurunan fungsi paru pada orang dewasa. Selain itu, variabel karakteristik individu dan faktor lingkungan rumah juga dianalisis dengan kejadian penurunan fungsi paru. Prevalensi penurunan fungsi paru pada orang dewasa di sekitar kawasan industri Pulo Gadung sebesar 38,5%.
Hasil analisis menunjukkan hubungan yang signifikan antara konsentrasi PM2,5 di udara dalam ruang dengan penurunan fungsi paru pada orang dewasa (OR = 3,31; nilai p = 0,003). Faktor lain yang mempengaruhi penurunan fungsi paru pada orang dewasa adalah jenis kelamin laki-laki (OR = 2,84; nilai p = 0,025), durasi pajanan (OR = 3,56; nilai p = 0,002), merokok (OR = 2,60; nilai p = 0,040), ventilasi (OR = 3,35; nilai p = 0,026), dan kelembaban (OR = 3,12; nilai p = 0,016). Akhirnya, kesimpulan dari penelitian ini adalah konsentrasi PM2,5 di udara dalam ruang berhubungan signifikan dengan penurunan fungsi paru pada orang dewasa.
PM2,5 is an important indicator of risk to health from particulate pollution. Exposure to indoor air pollution of PM2,5 has been associated with an increase in lung function impairment. Consequently, the intervention program must be started from environmental factors.
The aim of the study was to better understand the association between indoor PM2.5 concentration and the decline of adult lung function. Cross sectional study was conducted at the surrounding of Pulo Gadung Industries, East Jakarta.
This study was extended from March to May 2012. Researcher has selected 109 adults from 20 to 65 years of age by the stratified random sample to determine the incidence of lung function impairment and its relationship to indoor air pollution due to PM2.5. Lung function was measured by spirometry test to get the value of VC, FCV, FEV1, and FEV1/FCV. Indoor PM2.5 concentration was obtained from measurement by dust track. The Odds Ratio (OR) for the effect of indoor PM2,5 concentration on lung function in adult was analyzed by logistic regression model. Besides that, individual variables and health housing variables were analyzed with the decline of adult lung function too. The prevalence of the decline of adult lung function in the surrounding of Pulo Gadung Industries was 38,5%.
The analysis showed significantly association between indoor PM2.5 concentration and the decline of adult lung function (OR = 3,31; p value = 0,003). Another factors that influenced the decline of adult lung function were the men gender (OR = 2,84; p value = 0,025), the duration of exposure (OR = 3,56; p value = 0,002 ), smoking (OR = 2,60; p value = 0,040), ventilation (OR = 3,35; p value = 0,026), and humidity (OR = 3,12; p value = 0,016). Finally, the conclusion of this study is indoor PM2,5 concentration was significantly associated with the decline of adult lung function.

 File Digital: 1

 Kata Kunci

 Metadata

No. Panggil : S-Pdf
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Subjek :
Penerbitan : Depok: Fakultas Kesehatan Masyarakat Universitas Indonesia, 2012
Program Studi :
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : computer
Tipe Carrier : online resource
Deskripsi Fisik : xv, 143 pages : illustration ; 30 cm
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
No. Panggil No. Barkod Ketersediaan
S-Pdf 14-17-366718257 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20319881