Rasio jarak hiomental sebagai prediktor sulit intubasi terhadap ras Deutero-Melayu di RSUPNCM : perbandingan dengan skor Mallampati dan jarak Tiromental = Hyomental distance ratio as predictor of difficult intubation to Deutero-Malay race in RSUPN Cipto Mangunkusumo : comparation with Mallampati score and Thyromental distance / Eko Wahyudi

Eko Wahyudi; Aida Rosita Tantri, supervisor; Rudyanto Sedono, supervisor; Aries Perdana, examiner; Dita Adityaningsih, examiner; Riyadh Firdaus, examiner (Fakultas Kedokteran Universitas Indonesia, 2012)

 Abstrak

ABSTRAK
Latar Belakang : Kami mengevaluasi kegunaan dari pemeriksaan rasio jarak
hiomental (HMDR,hyomental distance ratio), yang didefinisikan sebagai rasio
dari jarak hiomental (HMD,hyomental distance) posisi kepala ekstensi maksimal
dengan posisi kepala netral, dalam memprediksi kesulitan visualisasi laring pada
pasien-pasien normal, yang dilakukan pemeriksaan prediktor-prediktor jalan
napas praoperasi dengan skor Mallampati dan jarak tiromental (TMD,
tyhyromental distance) sebagai pembanding.
Metode Penelitian : Praoperasi, kami menilai empat prediktor jalan napas pada
169 orang dewasa yang menjalani anestesi umum. Pelaku laringoskopi adalah
residen anestesiologi minimal tahun ke 2, dan menilai skor Cormack-Lehane(CL)
yang dimodifikasi. Sulit visualisasi laring (DVL,difficult visualization of the
larynx) didefinisikan sebagai CL derajat 3 atau 4. Titik potong optimal (The cutoff
point) untuk setiap tes ditentukan pada titik maksimal daerah di bawah
kurva dalam kurva ROC (Receiver Operating Characteristic). Skor Mallampati
dengan derajat ≥ 3 sebagai prediktor DVL. Untuk TMD ≤ 65 mm dianggap
sebagai prediktor DVL.
Hasil : Didapatkan 21 (12,4%) orang pasien dengan sulit visualisasi laring(DVL).
HMDR memiliki hubungan yang bermakna terkait dengan DVL. HMDR dengan
titik potong optimal 1,2 memiliki akurasi diagnostik yang lebih besar (dengan area
di bawah kurva 0.694), dibandingkan prediktor tunggal lainnya (P <0,05), dan
HMDR sendiri menunjukkan validitas diagnostik yang lebih besar (sensitivitas,
61,9%, spesifisitas, 69,6%) dibandingkan dengan prediktor lainnya.
Kesimpulan :HMDR dengan ambang batas uji 1,2 adalah prediktor klinis handal
dalam memprediksi kesulitan dalam visualisasi laring.

ABSTRACT
Background: We evaluated the usefulness of the hyomental distance (HMD) ratio
(HMDR), defined as the ratio of the HMD at the extreme of the head extension to
that in the neutral position, in predicting difficult visualization of the larynx
(DVL) in apparently normal patients, by examining the following preoperative
airway predictors: the modified Mallampati test, HMD in the
neutral position, HMD and thyromental distance at the extreme of head extension
and HMDR.
Methods : Preoperatively, we assessed the four airway predictors in 169 adult
patients undergoing general anesthesia. A second years resident, performed all of
the direct laryngoscopies and graded the views using the modified Cormack and
Lehane scale. DVL was defined as a Grade 3 or 4 view. The optimal cutoff points
for each test were determined at the maximal point of the area under the curve in
the receiver operating characteristic curve. For the modified Mallampati test,
Class ≥ 3 was predefined as a predictor of DVL. And thyromental distance (TMD)
≤ 65 mm was predefined as a predictor of DVL.
Results : The larynx was difficult to visualize in 21 (12,4%) patients. The HMDR
with the optimal cutoff point of 1.2 had greater diagnostic accuracy (area under
the curve of 0.694), with significantly related to DVL (P <0.05), and it alone
showed a greater diagnostic validity profile (sensitivity, 61,9%; specificity,
69,6%) than any other predictor.
Conclusions : The HMDR with a test threshold of 1.2 is a clinically reliable
predictor of DVL.

 File Digital: 1

Shelf
 T-Eko Wahyudi.pdf :: Unduh

LOGIN required

 Metadata

No. Panggil : T-Pdf
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Subjek :
Penerbitan : [Place of publication not identified]: Fakultas Kedokteran Universitas Indonesia, 2012
Program Studi :
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : unmediated ; computer
Tipe Carrier : volume ; online resource
Deskripsi Fisik : xiii, 46 pages ; 28 cm + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
No. Panggil No. Barkod Ketersediaan
T-Pdf TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20330048