Analisa Efisiensi Pada Unjuk Kerja PLTU 450 Watt Dengan Variasi Temperatur Superheater 205 OC = Efficiency Analysis Of 450 Watt Steam Power Plant Performance With Superheater Temperature Variation 205 OC

Ibnu Roihan; Raldi Artono Koestoer, supervisor; Nandy Putra, examiner; Engkos Achmad Kosasih, examiner; Imansyah Ibnu Hakim, examiner (Fakultas Teknik Universitas Indonesia, 2013)

 Abstrak

Pada data skripsi 2011, efisiensi termal PLTU, khususnya pada kondisi superheater 205 OC, hanya menunjukkan sekitar 3.8%. Dalam uji coba yang dilakukan di tahun 2013, jika dibandingkan dengan data 2011, heat loss yang terjadi di keluaran condenser menuju feed water tank dapat dikurangi hingga mencapai 66.66%, yang berarti adanya peningkatan usaha pengurangan pelepasan energi ke lingkungan sebesar 66.61% atau sekitar 100.46 [kJ/kg]. Tetapi hasil positif tersebut tidak sebanding dengan hasil pada keluaran superheater menuju turbin. Dibandingkan dengan data 2011, adanya penurunan energi sebesar 26 [kJ/kg] atau sebesar 33.46%. Sehingga efisiensi PLTU pada tahun 2013 turun menjadi 2.3%. Indikasi awal adalah adanya gejala fouling atau penumpukan kerak kotoran sisa pemanasan uap sehingga menyebabkan suhu uap turun sebesar hingga 25%, dari 205 OC menjadi 155 OC.

In 2011 final project, thermal efficiency of steam power plant, especially with superheater temperature condition 205 OC, just indicate about 3.8%. In 2013 experiment, if compared with 2011 result, heat loss at out of condenser to feed water tank can decreased until 66.66%, there is upgrading for work decreasing energy loss to surroundings as big as 66.61% or 100.46 [kJ/kg]. But the positive result not comparable with the result out of superheater to turbine. As compared to 2011 result, there is decreasing energy as big as 26 [kJ/kg] or 33.46%. With the result that, thermal efficiency of steam power plant in 2013 decrease become 2.3%. First Indication is there is fouling in pipe distribution from superheater to turbine, until cause vapor temperature decrease as big as 25%, from 205 OC become 155 OC.

 File Digital: 1

Shelf
 S46883-Ibnu Roihan.pdf :: Unduh

LOGIN required

 Metadata

No. Panggil : S46883
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Subjek :
Penerbitan : Depok: Fakultas Teknik Universitas Indonesia, 2013
Program Studi :
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : unmediated
Tipe Carrier : volume
Deskripsi Fisik : xvi, 162 pages : illustration ; 30 cm + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
No. Panggil No. Barkod Ketersediaan
S46883 14-23-12744702 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20347227