:: UI - Skripsi Membership :: Kembali

UI - Skripsi Membership :: Kembali

Analisis pengaruh renovasi struktur pabrik terhadap respon dinamik = Analysis of the effect from structural plant renovations against dynamic response

Pakpahan, Bram Timoteus Setiadi; Yuskar Lase, supervisor (Fakultas Teknik Universitas Indonesia, 2013)

 Abstrak

Untuk meningkatkan kapasitas produksi,sebuah struktur pabrik direnovasi berupaperkuatan komponen struktur yang sudah ada serta penambahan komponen struktur dan pondasi baru.Pada awalnya, struktur ini mengalami getaran akibat beban dinamik mesin flash gas bag filter, namun setelah direnovasigetaran tersebut menghilang. Melalui penelitian ini dikaji penyebab menghilangnya getaran tersebut dengan cara memodelkan struktur pabrik sebelum dan sesudahrenovasi serta memodelkanbeban mesin sebagai1 beban dinamik impuls. Pada permodelan beban gravitasi, urutan pembebanan pada struktur yang sudah ada maupun struktur yang sudah direnovasi ikut diperhitungkan. Dari hasil permodelan tersebut akan didapatkan rasio tegangan akibat beban mati pada struktur sebelum renovasi, dan rasio tegangan akibat kombinasi pembebanan pada struktur setelah direnovasi.Dan didapatkan juga nilai respon dinamik struktur yang berupa acceleration, displacement, dan velocity yang berkurang secara signifikan setelah direnovasi. Struktur pabrik sebelum direnovasi menunjukkan respon dinamik yang masuk dalam kategori uncomfortableberdasarkan standar internasional untuk skala getaran ketidaknyamanan. Namun, ketika struktur pabrik tersebut sudah direnovasi, respon dinamik yang didapatkan akan berada pada kategori not uncomfortable.

To increase production capacity, a renovated plant structure components such as retrofitting existing structures and structural components as well as the addition of a new foundation. At first, these structures undergo the vibration due to dynamic loads from flash gas bag filter engine, but after the renovation the vibration disappears. Through this study examined the causes of the disappearance of the vibration by way of modeling plant structure before and after the renovation as well as modeling the engine load as 1 dynamic impulse load. In the gravity load modeling, the sequence of loading on existing structures or structures that have been renovated are considered. From the modeling results will be obtained due to the dead load stress ratio on the structure before the renovation, and the ratio of stress due to the combination of loading on the structure after being renovated. And also the value obtained in the form of structural dynamic response acceleration, displacement, and velocity were reduced significantly after the renovation. Plant structure before it was renovated structure shows that the dynamic response in the category uncomfortable based on international standards for vibration-scale inconvenience. However, when the structure of the plant has been renovated, the dynamic response will be obtained in the category of not uncomfortable.

 File Digital: 1

Shelf
 S46982-Analisis pengaruh.pdf :: Unduh

LOGIN required

 Metadata

No. Panggil : S46982
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Subjek :
Penerbitan : Depok: Fakultas Teknik Universitas Indonesia, 2013
Program Studi :
Bahasa : ind
Sumber Pengatalogan :
Tipe Konten :
Tipe Media :
Tipe Carrier :
Deskripsi Fisik : xxiii, 131 hlm. : ill. ; 28 cm
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
No. Panggil No. Barkod Ketersediaan
S46982 14-19-025672677 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20347611