Pemodelan dan simulasi dynamic voltage restorer (DVR) untuk mitigasi lendutan tegangan pada sistem distribusi tegangan rendah = Modeling and simulation of dynamic voltage restorer (DVR) for voltage sag mitigation in low voltage distribution system
Kurniawan Widi Pramana;
Ridwan Gunawan, supervisor; Rudy Setiabudy, examiner; Iwa Garniwa M.K., examiner
([Publisher not identified]
, 2013)
|
ABSTRAK Dewasa ini, masalah kualitas daya semakin menjadi perhatian karena segalasesuatu yang terjadi akibat gangguan pada kualitas daya dapat menyebabkankerugian yang besar khususnya bagi pelanggan industri. Sebuah alat yangdinamakan Dynamic Voltage Restorer (DVR) telah berhasil disimulasikan untukmemitigasi masalah kualitas daya yang paling sering dihadapi oleh industri, yaitulendutan tegangan yang disebabkan karena gangguan hubung singkat. Dari hasilsimulasi lendutan tegangan yang disebabkan karena gangguan tiga fasa ke tanah,gangguan satu fasa ke tanah dan gangguan fasa ke fasa, serta dengan menerapkanskenario terjadinya gangguan tiga fasa ke tanah dengan adanya penambahanbeban dapat membuktikan bahwa DVR yang dimodelkan dan disimulasikan dapatdengan baik digunakan untuk memitigasi lendutan tegangan yang diakibatkanoleh gangguan-gangguan tersebut, yakni dapat mempertahankan level teganganbeban sensitif sehingga level tegangan beban sensitif tersebut tetap berada padarentang yang diijinkan yaitu antara 0,9 pu sampai 1,1 pu dengan error maksimumsebesar 1,4% dari level tegangan normal yang bernilai sebesar 1 pu. ABSTRACT Today, power quality issues are increasingly becoming a concern becauseeverything that occurs due to disturbance in the power quality can cause a greatloss especially for industrial customers. A device called Dynamic VoltageRestorer (DVR) has been successfully simulated to mitigate one of the mostcommon power quality problems faced by industrial customers namely voltagesag caused by short circuit. From the simulation results, i.e voltage sag caused bythree phase to ground fault, one phase to ground fault and phase to phase fault andalso applying one additional scenario i.e three phase to ground fault by addingadditional load, can prove that the designed DVR can effectively be used tomitigate the occurence of voltage sag caused by the earlier mentioned causes.DVR can maintain the level of voltage so that it keep steady between 0,9 pu ? 1,1pu with maximum error of 1,4% from the normal voltage level i.e 1 pu. |
![]()
|
No. Panggil : | T35702 |
Entri utama-Nama orang : | |
Entri tambahan-Nama orang : | |
Entri tambahan-Nama badan : | |
Subjek : | |
Penerbitan : | [Place of publication not identified]: [Publisher not identified], 2013 |
Program Studi : |
Bahasa : | ind |
Sumber Pengatalogan : | LibUI ind rda |
Tipe Konten : | rdacontent |
Tipe Media : | unmediated ; computer |
Tipe Carrier : | volume ; online resource |
Deskripsi Fisik : | xiv, 87 pages : ill ; 28 cm + appendix |
Naskah Ringkas : | |
Lembaga Pemilik : | Universitas Indonesia |
Lokasi : | Perpustakaan UI, Lantai 3 |
No. Panggil | No. Barkod | Ketersediaan |
---|---|---|
T35702 | 15-20-553488754 | TERSEDIA |
Ulasan: |
Tidak ada ulasan pada koleksi ini: 20349354 |