:: UI - Skripsi Open :: Kembali

UI - Skripsi Open :: Kembali

Studi eksperimental TiO2 Nanofluida terhadap kinerja penghantaran panas Sintered Wick Heat Pipe = experimental study of TiO2 Nanofluid to Sintered Heat Pipe Thermal Performance

Andyanto; Rosari Saleh, supervisor; Nandy Setiadi Djaya Putra, supervisor; Djoko Triyono, examiner; Efta Yudiarsah, examiner (Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2012)

 Abstrak

Saat ini nanofluida menarik perhatian karena memiliki konduktivitas panas yang tinggi dan dapat terdispersi dengan baik. Nanofluida TiO2-akuades dipilih sebagai fluida kerja untuk meningkatkan kinerja heat pipe. Penelitian dimulai dari pembuatan nanopartikel TiO2 dengan metode kopresipitas. Nanopartikel tersebut digunakan untuk pembuatan nanofluida dengan metode dua langkah. Nanofluida akan dikarakterisasi UV-Vis, pengukuran konduktivitas panas dan viskositas. Heat pipe dibuat dari pipa tembaga dengan sintered wick yang diukur persebaran temperatur pipanya dan dilakukan variasi konsentrasi nanofluida, jumlah fluida kerja, dan sudut kemiringan pipa untuk mencari kinerja heat pipe yang terbaik.
TiO2 nanopartikel yang dibuat memiliki struktur anatase dan ukuran kristal 33nm. Hasil pengukuran absorbansi UV-Vis nanofluida menunjukkan absorbansi nanofluida bertambah dengan meningkatnya konsentrasi namun pada konsentrasi 3% dan 5% terjadi penurunan absorbansi. Konduktivitas panas dan viskositas nanofluida meningkat dengan meningkatnya konsentrasi. Hal ini berkaitan dengan teori agregasi.
Kinerja heat pipe yang menggunakan nanofluida menunjukkan peningkatan dengan meningkatnya konsentrasi namun pada konsentrasi 3% dan 5% kinerja heat pipe lebih rendah dari 1% seperti pada pengukuran absrobansi UV-Vis. Untuk membuktikan pengaruh agregasi dilakukan pengukuran temperatur heat pipe yang sudah didiamkan selama satu bulan dan diperoleh hasil menyerupai fluida dasar. Variasi sudut tidak menunjukkan perubahan yang signifikan dan jumlah fluida kerja yang terbaik adalah 60%.

Nanofluid attracted a great attention because it has high thermal conductivity and can be well dispersed. Nanofluid TiO2-distilled water was selected as the working fluid to improve the kinerjance of heat pipes. The study started from the manufacture of TiO2 nanoparticles with coprecipitate method. The nanoparticles will be used to manufacture nanofluid with two-step method and they will be characterized with UV-Vis, and measured thermal conductivity and viscosity. Heat pipe created using copper pipe with sintered wick and would measured the temperature distribution of pipes varying nanofluid concentration, the amount of the working fluid, and the tilt angle of the pipe to find the best kinerjance of heat pipes.
TiO2 nanoparticles were anatase structure with crystallite size 33nm. The UV-Vis of nanofluida showed the absorbance of nanofluid increased with increasing concentration but the concentration of 3% and 5% declined in absorbance. Nanofluid thermal conductivity and viscosity increases with increasing concentration. All this relates to the occurrence of aggregation.
Kinerjance of heat pipe that uses nanofluida showed an increase with increasing concentration but the concentration of 3% and 5% showed heat pipe kinerjance were lower than 1% as it did in the measurement of UV-Vis absrobansce. To proved aggregation, heat pipe allowed to stand for 1month and measured the temperature of the heat pipe and obtained results resemble basic fluid. Effect of tilt variation was unsignificant and the influence of variations amount of the optimal working fluid at 60%.

 File Digital: 1

 Metadata

No. Panggil : S45696
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Penerbitan : Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2012
Program Studi :
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : unmediated ; computer
Tipe Carrier : volume ; online resource
Deskripsi Fisik : xi, 62 pages ; illustration ; 30 cm
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
No. Panggil No. Barkod Ketersediaan
S45696 14-22-58265196 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20353414