ABSTRAK Tujuan: Penelitian ini bertujuan untuk mengevaluasi perbedaan berbagai parameterposturografi pada risiko jatuh derajat ringan dan sedang.Metode: Dilakukan studi potong lintang pada 163 usila yang mampu ambulasimandiri, terdiri dari 108 subjek dengan risiko jatuh ringan dan 55 subjek denganrisiko jatuh sedang yang datang ke poli geriatri terpadu dan poli DepartemenRehabilitasi Medik RSCM. Parameter posturografi statik (Gravicorder GS-Anima3000, Tokyo-Japan) adalah panjang ayun tubuh (PA), kecepatan ayun tubuh (KA),Luas area (LA), Romberg quotient (RQ) dan deviasi Centre of Pressure (COP).Penilaian posturografi dilakukan dalam 4 kondisi yaitu keadaan mata terbuka dantertutup serta dengan atau tanpa busa. Risiko jatuh dinilai dengan Berg Balance Scale(BBS).Hasil: Hasil penelitian menunjukkan adanya perbedaan nilai PA, KA, LA dan RQantara kedua kelompok risiko jatuh, namun hanya nilai LA yang bermakna secarastatistik. Terdapat kecenderungan deviasi COP ke arah antero-posterior (AP)dibandingkan ke arah medio-lateral (ML) pada kedua kelompok risiko jatuh.Kesimpulan: Tidak terdapat perbedaan yang bermakna antara panjang ayun tubuh,kecepatan ayun tubuh serta Romberg quotient pada kelompok usila dengan risikojatuh ringan dan risiko jatuh sedang. Terdapat perbedaan yang bermakna luas areaayun tubuh pada kelompok usila dengan risiko jatuh ringan dan risiko jatuh sedang.Kata kunci: usila, risiko jatuh, posturografi statik, Berg Balance Scale ABSTRACT Study purpose: To evaluate different parameters of static posturography in elderlywith mild and moderate risk of falls that lives in community.Methods: A cross sectional study was conducted in 163 elderly who can ambulateindependently without assistive device in Poliklinik Geriatri Terpadu, PM&Rdepartment and Neuro-Otology division ENT department RSCM. There were 108subjects with mild risk of falls and 55 subjects with moderate risk of falls. Staticposturography (Gravicorder GS-Anima 3000, Tokyo-Japan) parameters were lengthof body sway (LNG), velocity of body sway (LNG/TIME), Envelope Area (ENV),Romberg quotient (RQ) and Centre of Pressure (COP) deviation. Posturographymeasurement was taken in four conditions, with eyes open (EO) and closed (EC) andalso with and without rubber foam (R). Risk of falls measurement was using BergBalance Scale (BBS).Results: There were different values in length of body sway (LNG), velocity of bodysway (LNG/TIME) and Romberg quotient (RQ). Envelope Area (ENV) hasstatistically significant value between mild and moderate risk of falls. The COP wastended to deviate more in antero-posterior (AP) than in medio-lateral (ML) direction.Conclusion: The values of length of body sway (LNG), velocity of body sway(LNG/TIME) and Romberg quotient (RQ) has not statistically significant. EnvelopeArea (ENV) has statistically significant value between mild and moderate risk of falls |