:: UI - Skripsi Membership :: Kembali

UI - Skripsi Membership :: Kembali

Kualitas fisik biologis udara di ruang ICU Rumah Sakit (studi kasus rumah sakit umum daerah Tarakan) = Physical biological quality of air in ICU room at Hospital (case study Tarakan regional public hospital)

M. Syafaat Nur; Setyo Sarwanto Moersidik, supervisor; El Khobar Muhaemin Nazech, supervisor; Gabriel Soedarmini Boedi Andari, examiner; Nyoman Suwartha, examiner ([, Fakultas Teknik Universitas Indonesia], 2014)

 Abstrak

[ABSTRAK
Kualitas udara di ruang ICU perlu diperhatikan karena kerentanan pasien akan penyakit dan menghindarinya dari infeksi nosokomial. Beberapa indikator dari pencemar udara dalam ruang adalah konsentrasi bakteri dan konsentrasi jamur. Pengambilan sampel bakteri dan jamur di udara menggunakan alat EMS serta media kultur TSA untuk bakteri dan media kultur PDA untuk jamur. Penelitian ini bertujuan untuk mengetahui hubungan antara konsentrasi bakteri dan jamur berdasarkan besarnya intensitas cahaya, kelembaban, dan temperatur. Intensitas cahaya, kelembaban, dan temperatur terhadap konsentrasi bakteri memiliki korelasi Spearman Rank sebesar -0,043; 0,033; -0,194 dan korelasi analisi regresi linear sebesar -0,115; 0,017; -0,168. Intensitas cahaya, kelembaban, dan temperatur terhadap konsentrasi jamur memiliki korelasi Spearman Rank sebesar -0.231; 0,062; -0,095 dan korelasi analisi regresi linear sebesar -0,265; 0,072; -0,192.

ABSTRACT
, Air quality in ICU Room need to be considered as susceptibility to disease and avoid
nosocomial infection. Some indicators of indoor air pollutants are bacteria and fungi. Using
EMS and TSA as a media culture for bacteria and PDA as a media culture for fungi. In this
study, the concentrations of bacteria and fungi were analyzed based on intensity of ray,
humidity, and temperature. Intensity of ray, humidity, and temperature in the room have a
relationship with the concentration of bacteria with the Spearman Rank correlation
coefficient of -0.043; 0.033; -0.194 and with linear regretion analysis correlation coefficient
of -0.115; 0.017; -0.168. Intensity of ray, humidity, and temperature in the room have a
relationship with the concentration of fungi with the Spearman Rank correlation coefficient
of -0.231; 0.062; -0.095 and with linear regretion analysis correlation coefficient of -0.265;
0.072; -0.192.]

 File Digital: 1

Shelf
 S54939-M Syafaat Nur.pdf :: Unduh

LOGIN required

 Metadata

No. Panggil : S54939
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Subjek :
Penerbitan : [Place of publication not identified]: [, Fakultas Teknik Universitas Indonesia], 2014
Program Studi :
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : unmediated ; computer
Tipe Carrier : volume ; online resources
Deskripsi Fisik : xi, 96 pages : illustration ; 30 cm + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
No. Panggil No. Barkod Ketersediaan
S54939 14-18-499687084 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20385542