Dosis glandular rerata dan kualitas citra fantom cdmam pada pesawat mamografi siemens mammomat inspiration = Mean glandular dose and cdmam phantom image quality for siemens mammomat inspiration

Hanna Vita Paulana; Djarwani Soeharso Soejoko, supervisor; Kristina Tri Wigati, supervisor; Supriyanto Ardjo Pawiro, examiner; Arreta Rei, examiner ([Publisher not identified] , 2014)

 Abstrak

[ABSTRAK
Dalam melakukan skrinning payudara, pesawat mamografi harus dapat mencitrakan mikrokalsifikasi dengan ukuran sekecil mungkin. Namun besar dosis glandular rerata (mean glandular dose, MGD) yang sampai ke payudara tidak boleh melebihi batas yang dianjurkan. Untuk mencapai tujuan tersebut maka kombinasi target/filter yang digunakan saat melakukan pengeksposan harus disesuaikan terhadap ketebalan payudara. Evaluasi kualitas citra terhadap variasi kombinasi target/filter dapat dilakukan dengan menggunakan fantom CDMAM. Dari dua metode yang digunakan dalam mengevaluasi citra fantom CDMAM, metode digital lebih unggul dibanding metode manual. Selain evaluasi citra, nilai MGD yang diterima fantom dihitung dengan cara mengalikan nilai kerma udara disetiap ketebalan dengan faktor konversi kerma udara menjadi MGD. MGD dihitung menggunakan persamaan dan faktor konversi yang dipublikasikan IAEA Human Health Series No. 17 - Quality Assurance Programme for Digital Mammography, kemudian dibandingkan dengan perhitungan berdasarkan tiga publikasi lainnya. Kualitas citra terbaik untuk fantom ketebalan di bawah 32 mm diperoleh dengan menggunakan kombinasi target/filter Mo/Mo, sedangkan untuk ketebalan di atas 45 mm terbaik menggunakan Mo/Rh.

ABSTRACT
, In performing breast screening, a mammography must be capable of imaging
microcalcifications with the smallest possible size. However, the mean glandular
dose (MGD) should not exceed the recommended limits. To achieve the goal then
the utilization of target/filter combination should be adjusted to the thickness of
the breast. The evaluation of image quality against variations in target/filter
combinations can be done by using CDMAM phantom. There are two methods of
CDMAM phantom image quality assessment, and the digital method is considered
superior to the manual one. In addition to the evaluation of image quality, MGD
received by the phantom was also calculated by multiplying the air kerma value at
each thicknesses with the air kerma conversion factor into MGD. The calculation
of MGD follow the equation and convertion factors that published by IAEA
Human Health Series No. 17 – Quality Assurance Programme for Digital
Mammography, then being compared with three another publication. The best
image quality for the phantom thickness below 32 mm achieved by using Mo/Mo
target/filter combination, meanwhile for the phantom thickness above 45 mm
achieved by using Mo/Rh.]

 File Digital: 1

Shelf
 S55201-Hanna Vita Paulana.pdf :: Unduh

LOGIN required

 Metadata

No. Panggil : S55201
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Subjek :
Penerbitan : [Place of publication not identified]: [Publisher not identified], 2014
Program Studi :
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : unmediated ; computer
Tipe Carrier : volume ; online resources
Deskripsi Fisik : xii, 51 pages : illustration ; 30 cm + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
No. Panggil No. Barkod Ketersediaan
S55201 14-18-355708723 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20385934