Verifikasi dosis pada imrt dan vmat berbasis film gafchromic xr rv3 = Dose verification on imrt and vmat based on gafchromic film xr rv3 / Pamungkas Hudigomo
Pamungkas Hudigomo;
Supriyanto Ardjo Pawiro, supervisor; Djarwani Soeharso Soejoko, examiner; Mussadiq Musbach, examiner
(Universitas Indonesia, 2014)
|
ABSTRAK Telah dilakukan penelitian yang bertujuan untuk mengimplementasikan filmGafchromic XR-RV3 untuk verifikasi dosis radioterapi pada IMRT dan VMAT.Evaluasi dosis pada target ditentukan dengan meletakkan film Gafchromic XRRV3dan EBT2 padqa slab fantom Rando Alderson. Percobaan dilakukan denganmenggunakan Varian Clinac Trilogy, Inc. Proses simulasi terlebih dahuludilakukan pada fantom Rando Alderson bagian thorax dan pelvis di CT simulatorPhillips, Inc. Dua kasus perencanaan IMRT dan VMAT dibuat menggunakan TPSEclipse ver. 10. Film Gafchromic yang telah dipapar kemudian dipindaimenggunakan scanner Epson Perfection V700 ke dalam format tagged image file(.TIFF) dengan 72 dpi dan RGB 48 bit yang kemudian dianalisis menggunakanalgoritma in-house yang telah dikembangkan oleh penelitian sebelumnya. Dalampenelitian ini dilakukan perbandingan pengukuran distribusi dosis pada filmGafchromic XR-RV3 dan EBT2 untuk mendapatkan dosis rata-rata dalam bentukkurva histogram. Hasil penelitian ini memiliki persentase kesalahan terhadapdosis preskripsi pada kasus kanker prostat sebesar -4.85% pada film GafchromicEBT2 dan -1.94% pada film Gafchromic XR-RV3 dengan teknik penyinaranIMRT, sedangkan untuk teknik penyinaran VMAT sebesar -4.48% pada filmGafchromic EBT2 dan -7.47% pada film Gafchromic XR-RV3. Di sisi lain,persentase kesalahan terhadap dosis preskripsi pada kasus kanker paru-parudengan teknik penyinaran IMRT adalah 14.47% pada film Gafchromic EBT2 dan-4.37% pada film Gafchromic XR-RV3, sedangkan untuk teknik penyinaranVMAT sebesar 51.64% pada film Gafchromic EBT2 dan -28.07% pada filmGafchromic XR-RV3 ABSTRACT The research aims to implement Gafchromic XR-RV3 films in order to verify thedose of radiotherapy on IMRT and VMAT. The evaluation of targeted dose isdetermined by putting films of Gafchromic XR-RV3 and EBT2 on RandoAlderson slab fantom. The experiment was performed with Varian Clinac Trilogy,Inc. The simulation process was initially conducted on thorax and pelvis onPhillips Inc.’s CT Simulator. Two cases of IMRT and VMAT plans were madeusing Eclipse TPS ver. 10. Exposed Gafchromic films then scanned using EpsonPerfection V700 into (.TIF) format in 72 dpi and RGB 48 bit which was analyzedby in-house algorithm that had been developed on a previous research. Thecomparison between EBT2 and XR-RV3 Gafchromic films were used to obtainaverage dose in the form of histogram curve. The percentage of errors in the caseof prostate cancer toward the planned dose were -4.85% in EBT2 Gafchromicfilms and -1.94% in the XR-RV3 Gafchromic films on IMRT technique, whereasfor VMAT were -4.48% on EBT2 Gafchromic films and -7.47% on XR-RV3Gafchromic films. On the other hand, the percentage of errors in the case of lungcancer toward the planned dose with IMRT technique were 14.47% on EBT2Gafchromic films and -4.37% on XR-RV3 Gafchromic films, while for VMATwere 51.64% on EBT2 Gafchromic films and -28.07% on XR-RV3 Gafchromicfilms. |
![]()
|
No. Panggil : | S57739 |
Entri utama-Nama orang : | |
Entri tambahan-Nama orang : | |
Penerbitan : | [Place of publication not identified]: Universitas Indonesia, 2014 |
Program Studi : |
Bahasa : | ind |
Sumber Pengatalogan : | LibUI ita rda |
Tipe Konten : | text |
Tipe Media : | unmediated ; computer |
Tipe Carrier : | volume ; online resource |
Deskripsi Fisik : | xv, 65 pages : illustration ; 29 cm + appendix |
Naskah Ringkas : | |
Lembaga Pemilik : | Universitas Indonesia |
Lokasi : | Perpustakaan UI, Lantai 3 |
No. Panggil | No. Barkod | Ketersediaan |
---|---|---|
S57739 | TERSEDIA |
Ulasan: |
Tidak ada ulasan pada koleksi ini: 20402153 |