Studi eksperimental fenomena perpindahan kalor pada vertical two phase closed thermosyphon = Experimental study of heat transfer phenomenon on vertical two phase closed thermosyphon / Ficky Augusta Imawan
Ficky Augusta Imawan;
Nandy Setiadi Djaya Putra, supervisor; Irmansyah Ibnu Hakim, examiner; Agus Sunjarianto Pamitran, examiner; Engkos Achmad Kosasih, examiner
(Fakultas Teknik Universitas Indonesia, 2015)
|
ABSTRAK Sistem pendinginan pada spent fuel pool saat ini masih memilikiketergantungan terhadap sistem pendingin aktif. Sistem pendingin aktif adalahsistem pendingin yang memiliki ketergantungan terhadap energi listrik. Pada saatterjadi Station Blackout (SBO), sistem pendingin spent fuel pool tidak bekerja danlama kelamaan dapat menyebabkan peristiwa loss of pool coolant, serta dapatmenyebakan radiasi radioaktif kelingkungan. Salah satu alat penukar kalor yangdapat dikembangkan untuk menyelesaikan permasalahan tersebut adalah heatpipe. Pada penelitian ini, dilakukan pengujian heat pipe jenis two-phase closedthermosyphon (TPCT). TPCT merupakan alat penukar kalor pasif yang memilikikonduktivitas termal yang sangat tinggi dan sudah banyak dikembangkan padabanyak aplikasi. Geometri dari kontainer TPCT yang diuji adalah sepanjang 1,5mdiameter 1 inch, serta rasio yang sama pada bagian evaporator, adiabatik, dankondenser. Penelitian ini dilakukan untuk menguji pengaruh filling ratio fluidakerja dan inisiasi tekanan terhadap kinerja TPCT. Dari penelitian ini, diperolehfilling ratio optimum adalah pada 60% volume evaporator dan variasi inisiasitekanan memberikan karakteristik temperatur pada dinding TPCT yang berbeda. ABSTRACT The spent fuel pool cooling system nowadays still has dependency toactive cooling system.. Active cooling system is a cooling system that still hasdependency to electrical power. When Station Blackout (SBO) occurs, the spentradioactive radiation released to the environment. One of the heat exchanger thatcan be used to solve this problem is heat pipe. In this research, two phase closedthermosyphon were examined. TPCT is a passive heat transfer device which has avery high thermal conductivity and has been used for many applications, Thelength, 1 inch diameter, and each evaporator,adiabatic, and condenser has same ratio. The goal in this research are to find theFrom this research it has been found that the optimum filling ratio were 60% ofevaporator volume, and pressure initiation variation gave some difference on |
![]()
|
No. Panggil : | S58697 |
Entri utama-Nama orang : | |
Entri tambahan-Nama orang : | |
Subjek : | |
Penerbitan : | [Place of publication not identified]: Fakultas Teknik Universitas Indonesia, 2015 |
Program Studi : |
Bahasa : | ind |
Sumber Pengatalogan : | LibUI ind rda |
Tipe Konten : | text |
Tipe Media : | unmediated ; computer |
Tipe Carrier : | volume ; online resource |
Deskripsi Fisik : | xv, 73 pages : illustration ; 30 cm + appendix |
Naskah Ringkas : | |
Lembaga Pemilik : | Universitas Indonesia |
Lokasi : | Perpustakaan UI, Lantai 3 |
No. Panggil | No. Barkod | Ketersediaan |
---|---|---|
S58697 | TERSEDIA |
Ulasan: |
Tidak ada ulasan pada koleksi ini: 20402335 |