Full Description
Cataloguing Source | |
Content Type | text (rdacontent) |
Media Type | unmediated (rdacontent); Computer (rdadontent) |
Carrier Type | volume (rdacarrier); online resource (rdacarrier) |
Physical Description | xvi, 111 pages : illustration ; 28 cm + appendix |
Concise Text | |
Holding Institution | Universitas Indonesia |
Location | Perpustakaan UI, Lantai 3 |
- Availability
- Digital Files: 1
- Review
- Cover
- Abstract
Call Number | Barcode Number | Availability |
---|---|---|
S58473 | 14-23-18272606 | TERSEDIA |
No review available for this collection: 20402427 |
Abstract
Penelitian ini bertujuan untuk mengetahui Gambaran Kualitas Udara di Dalam Ruangan Pusat Perbelanjaan Y, Kota Depok, Tahun 2014 dengan melakukan pengukuran tingkat pajanan parameter fisik dan konsentrasi kontaminan kimia. Desain penelitian bersifat deskriptif analisis dengan pendekatan cross-sectional. Penelitian kuantitatif dilakukan melalui pengukuran tingkat pajanan parameter fisik dan konsentrasi kontaminan kimia udara dengan cara grab sampling menggunakan direct reading intrument. Penelitian kualitatif dilakukan melalui wawancara terstruktur kepada pekerja dengan keluhan subjektif sick building syndrome. Hasil dan kesimpulan dari penelitian ini adalah, parameter kualitas udara di dalam ruangan yang melewati nilai ambang batas adalah lain suhu, kelembaban, CO, SO2, PM2.5, dan PM10.
This study aims to overview the Indoor Air Quality in Shopping Center Y, Depok, 2014 by measuring the physical exposure level and chemical contaminants concentration. The design study is descriptive analysis with cross-sectional approach. Quantitative research conducted by measuring the physical exposure level and chemical contaminant concentrations by grab sampling using direct reading instruments. Qualitative research conducted through structured interviews to workers with sick building syndrome subjective complaints. The results and conclusions of this research is, the indoor air quality parameters that pass the threshold value is temperature, humidity, CO, SO2, PM2.5, and PM10.
This study aims to overview the Indoor Air Quality in Shopping Center Y, Depok, 2014 by measuring the physical exposure level and chemical contaminants concentration. The design study is descriptive analysis with cross-sectional approach. Quantitative research conducted by measuring the physical exposure level and chemical contaminant concentrations by grab sampling using direct reading instruments. Qualitative research conducted through structured interviews to workers with sick building syndrome subjective complaints. The results and conclusions of this research is, the indoor air quality parameters that pass the threshold value is temperature, humidity, CO, SO2, PM2.5, and PM10.