Evaluasi kesesuaian sistem proteksi kebakaran pada rancangan bangunan gedung RSPTN UI terhadap peraturan pemerintah Indonesia kasus ruang operasi = Evaluation of fire protection system design s compliance in rsptn ui in accordance with Indonesian goverment s regulations case study operation room / Sony Virawan Sonata
Sony Virawan Sonata;
Fatma Lestari, supervisor; Budiman Bela, examiner; Mila Tejamaya, examiner; Iqro Gelentar, examiner; Pangaribuan, Adrianus, examiner
(Fakultas Kesehatan Masyarakat Universitas Indonesia, 2014)
|
ABSTRAK Penelitian ini bertujuan untuk mengevaluasi kesesuaian sistem proteksikebakaranpada rancangan bangunan gedung RSPTN UI. Penelitian deskriptif inidilakukandengan telaah dokumen. Metode yang digunakan adalah evaluasi menggunakanchecklist sesuai dengan Permen PU No.26/PRT/M/2008, Perwal Depok No. 14Tahun 2012, Pedoman Teknis Prasarana Rumah Sakit yang dikeluarkan olehKemenkes pada tahun 2012, serta Standar Nasional Indonesia (SNI). Penelitian inijuga mengambil contoh kasus di ruang operasi untuk dibahas lebih mendalam.Hasil dari penelitian ini menunjukkan bahwasebagian besar sistem proteksikebakaran pada rancangan bangunan gedung RSPTN UI telah sesuai denganperaturan pemerintah Indonesia. Sistem proteksi kebakaran yang belum seluruhpersyaratannya terpenuhi yaitu pintu eksit, detektor dan alarm kebakaran, sistempipa tegak, alat pemadam api ringan, dan lif kebakaran. Oleh karena itu,diperlukan penyesuaian rancangan sistem proteksikebakaran tersebut agar sesuaidengan peraturan pemerintah Indonesia. ABSTRACT The aim of this study is to evaluate the compliance of fire protection systemdesign in RSPTN UI in accordance to Indonesian goverment’s regulations. Thisdescriptive study was conducted with document review. The method used is theevaluation in accordance with Permen PU No. 26/PRT/M/2008, Perwal DepokNo. 14 Year 2012, Technical Guideline of Hospital Facility, Ministry of Health,Year 2012, and Indonesian National Standard (SNI). Checklist from theseregulation had been developed and utilized as the tool for this study. This studyalso took a sample of cases in the operating room as a case study. The results ofthis study indicate that the majority of fire protection systems in RSPTN UIdesign is complied with Indonesian government regulations. Fire protectionsystems that not meet all the requirements are exit doors, detectors and fire alarm,standpipe systems, fire extinguisher, and fire elevator. Therefore, the necessaryadjustments to the design of the fire protection system to suit the Indonesiangovernment regulations. Therefore, required fire protection system designadjustment to suit the Indonesian goverment regulation. |
T42786-Sony Virawan Sonata.pdf :: Unduh
|
No. Panggil : | T42786 |
Entri utama-Nama orang : | |
Entri tambahan-Nama orang : | |
Entri tambahan-Nama badan : | |
Subjek : | |
Penerbitan : | Depok: Fakultas Kesehatan Masyarakat Universitas Indonesia, 2014 |
Program Studi : |
Bahasa : | ind |
Sumber Pengatalogan : | LibUI ind rda |
Tipe Konten : | text |
Tipe Media : | unmediated ; computer |
Tipe Carrier : | volume ; online resource |
Deskripsi Fisik : | xvii, 111 pages : illustration ; 28 cm + appendix |
Naskah Ringkas : | |
Lembaga Pemilik : | Universitas Indonesia |
Lokasi : | Perpustakaan UI, lantai 3 |
No. Panggil | No. Barkod | Ketersediaan |
---|---|---|
T42786 | 15-23-07615797 | TERSEDIA |
Ulasan: |
Tidak ada ulasan pada koleksi ini: 20404010 |