Analisis hasil pengukuran kualitas udara dalam ruangan perusahaan XXX di Jakarta 2015 = Analysis of indoor air quality measurement result on company XXX in Jakarta year 2015

Lulu Djanatha; Robiana Modjo, supervisor; Mila Tejamaya, examiner; Henry V. Matakupan, examiner (Fakultas Kesehatan Masyarakat Universitas Indonesia, 2015)

 Abstrak

Penelitian mengenai Analisis Hasil Pengukuran Kualitas Udara Dalam Ruangan Perusahaan XXX di Jakarta Tahun 2015, penelitian ini dilakukan terkait beberapa keluhan karyawan mengenai kualitas udara dalam ruangan kantor dan hasil dari pengukuran kualitas udara dalam kantor yang telah dilaksanakan pada September 2014.
Penelitian ini bertujuan untuk mengetahui apakah kualitas dalam ruangan perusahaan XXX sudah sesuai dengan standar dari pemerintah RI. Penelitian ini menggunakan metode analisis kualitatif deskriptif, pengambilan data dari penelitian ini dilaksanakan dengan menggunakan data hasil pengukuran kualitas udara dalam ruangan dan pelaksanaan wawancara dan observasi lapangan.
Hasil dari analisis kadar SO2, CO2, O2, Temperatur, Kelembaban, dan Laju Ventilasi pada beberapa area pengukuran tidak memenuhi standard. Saran yang penulis ajukan terkait menyesuaikan sistem udara (HVAC) dan pengontrolan kadar CO2 dalam ruangan. Serta melakukan penelitian lebih mendalam terkait kemungkinan gangguan kesehatan yang berhubungan dengan kualitas udara dalam ruangan.

Research on Analysis of Indoor Air Quality Measurement Result on Company XXX in Jakarta year 2015 was conducted in relation to some employee complaints regarding office indoor air quality and the results of air quality measurement in the office that have been held in September 2014.
This study aims to determine whether air quality indoor in Company XXX is comply with the standards of Indonesian government. This study uses descriptive qualitative analysis, retrieval of data from this study was conducted by using indoor air quality measurement data, interviews, and field observations.
Results of the analysis of the levels of SO2, CO2, O2, temperature, humidity, and ventilation rate in some measured areas did not meet the standard. Suggestions that the author submitted in association with this problem is to adjust the air conditioning system ( HVAC ) and to control the CO2 level in the building. Moreover, conduct more in-depth research related to the possibility of health problems caused by indoor air quality.

 File Digital: 1

Shelf
 S59011-lulu_djanatha.pdf :: Unduh

LOGIN required

 Metadata

No. Panggil : S59011
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Subjek :
Penerbitan : Depok: Fakultas Kesehatan Masyarakat Universitas Indonesia, 2015
Program Studi :
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : unmediated ; computer
Tipe Carrier : volume ; online resource
Deskripsi Fisik : xvi, 123 pages : illustration ; 28 cm + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
No. Panggil No. Barkod Ketersediaan
S59011 14-17-866456012 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20412445