Pengukuran profil dosis sinar-X computed tomography dengan variasi pitch menggunakan film gafchromic XR QA2 dan thermoluminescence dosimeter (TLD) = Measurement of dose profile computed tomography X ray with pitch variation using XR QA2 gafchromic and thermoluminescence dosimeter (TLD) / Septi Purwaningsih
Septi Purwaningsih;
Supriyanto Ardjo Pawiro, supervisor; Djarwani Soeharso Soejoko, co-promotor; Adhi Harmoko Saputro, examiner; I Putu Susila, examiner; Warsito, examiner
([Publisher not identified]
, 2015)
|
[ABSTRAK Penelitian ini bertujuan untuk mengetahui profil dosis sinar-x ComputedTomography dengan variasi pitch menggunakan film Gafchromic XR QA2 danTLD pada fantom kepala orang dewasa dan kepala pediatrik. Untuk tujuantersebut dilakukan pengukuran dan analisis profil dosis di sepanjang sumbu zrotasi scan pada pusat fantom dan beberapa tepi di kedalaman 1 cm, analisis profildosis pada posisi yang sama dengan nilai pitch yang berbeda, dan analisis profildosis pada kepala orang dewasa dan kepala pediatrik. Dari pengukuran dananalisis data diperoleh hasil profil dosis pada scan kepala orang dewasa dankepala anak-anak dengan nilai dosis maksimal di tengah, menurun pelan ke arahtepi dengan tendensi cenderung simetri. Profil dosis dengan variasi nilai pitch,diperoleh nilai dosis yang semakin menurun dengan bertambahnya nilai pitch.Profil dosis pada scan kepala orang dewasa memiliki nilai dosis lebih besar daripada dosis pada scan kepala pediatrik, karena scan kepala orang dewasamenggunakan mAs lebih besar. Hasil pengukuran menggunakan TLD diperolehdata yang bersifat disktrit, namun memiliki pola distribusi dan nilai dosis yanghampir sama dengan hasil dari pengukuran menggunakan film Gafchromic. Hasilpengukuran profil dosis menggunakan film Gafchromic didapatkan grafikkontinu. Nilai dosis maksimum hasil scan didapatkan pada posisi jam 12 danminimum pada posisi jam 6. Profil dosis pada pitch 0,75; 1 dan 1,5 mengalamifluktuasi dosis dengan amplitudo pada pitch 0,75 dan 1,5 mempunyai nilai yanglebih besar jika dibandingkan dengan amplitudo pada pitch 1. ABSTRACT This research aims to check pattern dose profile on the adult and pediatrichead scan. Comparing result measurement dose profile along the z- axis rotationat a depth 1 cm and center phantom with variety pitch. Measurement usingcylinder PMMA homogeneous phantom diameter 16 cm and 10 cm using XRQA2 Gafchromic film and TLD. Result of research get dose profile adult andpediatric head scan have same pattern, the maximum dose in the middle andtendency symmetry in the edge. Value dose proportional with value of pitch. Dosein the adult head more than dose pediatric head because dose in adult head scanusing bigger mAs. Dose of TLD measurement values obtained are discrete, buthas a distribution and dose values are almost the same as the measurement resultsin XR QA2 Gafchromic film. Result of Gafchromic film measurement is continuegraphic. The maximum dose of the scan results at the 12 o'clock position andminimum at 6 o'clock position. Result of research get fluctuated dose andamplitude of pitch 0.75 and 1.5 have greater than amplitude pitch 1., This research aims to check pattern dose profile on the adult and pediatrichead scan. Comparing result measurement dose profile along the z- axis rotationat a depth 1 cm and center phantom with variety pitch. Measurement usingcylinder PMMA homogeneous phantom diameter 16 cm and 10 cm using XRQA2 Gafchromic film and TLD. Result of research get dose profile adult andpediatric head scan have same pattern, the maximum dose in the middle andtendency symmetry in the edge. Value dose proportional with value of pitch. Dosein the adult head more than dose pediatric head because dose in adult head scanusing bigger mAs. Dose of TLD measurement values obtained are discrete, buthas a distribution and dose values are almost the same as the measurement resultsin XR QA2 Gafchromic film. Result of Gafchromic film measurement is continuegraphic. The maximum dose of the scan results at the 12 o'clock position andminimum at 6 o'clock position. Result of research get fluctuated dose andamplitude of pitch 0.75 and 1.5 have greater than amplitude pitch 1.] |
![]()
|
No. Panggil : | T43843 |
Entri utama-Nama orang : | |
Entri tambahan-Nama orang : | |
Entri tambahan-Nama badan : | |
Subjek : | |
Penerbitan : | [Place of publication not identified]: [Publisher not identified], 2015 |
Program Studi : |
Bahasa : | ind |
Sumber Pengatalogan : | LibUI ind rda |
Tipe Konten : | text |
Tipe Media : | computer |
Tipe Carrier : | online resource |
Deskripsi Fisik : | xix, 121 pages : illustration ; 28 cm + appendix |
Naskah Ringkas : | |
Lembaga Pemilik : | Universitas Indonesia |
Lokasi : | Perpustakaan UI, Lantai 3 |
No. Panggil | No. Barkod | Ketersediaan |
---|---|---|
T43843 | TERSEDIA |
Ulasan: |
Tidak ada ulasan pada koleksi ini: 20414565 |