Uji sensitivitas metode reverse dot blot sebagai metode alternatif pemeriksaan rutin penegakan diagnosis leukemia mielositik kronik (lmk) = Sensitivity test of reverse dot blot method as an alterntive method for routine examination of chronic myelogenous leukemia (cml) / Siti Fatimah Selasih
Siti Fatimah Selasih;
Anom Bowolaksono, supervisor; Ahmad Rusdan Handoyo, supervisor; Ratna Yuniati, examiner; Upi Chairun Nisa, examiner
([Publisher not identified]
, 2016)
|
ABSTRAK Imatinib mesylate merupakan salah satu terapi pengobatan untuk leukemia mielositik kronik (LMK). Terapi pengobatan tersebut membutuhkan pemeriksaan secara rutin terhadap jumlah transkrip gen BCR-ABL1, untuk mengetahui respons pasien terhadap terapi. Berdasarkan hasil penelitian sebelumnya, metode Reverse Dot Blot (RDB) telah diketahui dapat secara spesifik mendeteksi tipe translokasi BCR-ABL1. Penelitian dilakukan untuk mengetahui tingkat sensitivitas diagnostik metode RDB sebagai metode pemeriksaan rutin pasien LMK yang menjalani terapi Imatinib mesylate. Uji sensitivitas diagnostik dilakukan dengan membandingkan metode RDB dan metode quantitative real time polymerase chain reaction (Q-PCR) pada penderita LMK yang menjalankan terapi Imatinib mesylate. Jumlah minimal transkrip BCR-ABL1 berdasarkan nilai international scale (IS) yang dapat dideteksi dengan metode RDB adalah 1%. Uji sensitivitas menunjukkan bahwa tingkat sensitivitas metode RDB sebesar 86,67% dengan tingkat spesifisitas 100%. Berdasarkan penelitian ini dapat disimpulkan metode RDB dapat menjadi metode penegakan diagnosis LMK, dan menjadi metode alternatif yang berpotensi untuk pemeriksaan awal pada tiga bulan pertama setelah terapi pengobatan dilakukan. ABSTRACT Imatinib mesylate is a curing therapy for chronic myelogenous leukemia (CML). The therapy is given simultaneously with regular examination of BCR-ABL1 gene transcript amount to monitor patient’s responses. According to the latest research report, Reverse Dot Blot (RDB) method has been known as a method whichis able to detect type of BCR-ABL1 translocation specifically. This study was conducted to determine diagnostic sensitivity level of RDB method as a regular examination to CML patients undergoing Imatinib mesylate therapy. Diagnostic sensitivity test was performed by comparing RDB method and quantitative real time polymerase chain reaction (Q-PCR) method. Minimal amount of BCR-ABL1 transcript, based on international scale (IS) score, which is able to be detected by RDB method is 1%. Sensitivity test result show that the sensitivity level of RDB method is 86,67% while the level of specificity is 100%. Hence, we could summarize that RDB method is capable to be a CML diagnosis enforcement method and can be a potential alternative method on first three months examination during therapy. |
![]()
|
No. Panggil : | S64473 |
Entri utama-Nama orang : | |
Entri tambahan-Nama orang : | |
Entri tambahan-Nama badan : | |
Subjek : | |
Penerbitan : | [Place of publication not identified]: [Publisher not identified], 2016 |
Program Studi : |
Bahasa : | ind |
Sumber Pengatalogan : | LibUI ind rda |
Tipe Konten : | text |
Tipe Media : | unmediated ; computer |
Tipe Carrier : | volume ; online resources |
Deskripsi Fisik : | xii, 46 pages : illustration ; 28 cm + appendix |
Naskah Ringkas : | |
Lembaga Pemilik : | Universitas Indonesia |
Lokasi : | Perpustakaan UI, Lantai 3 |
No. Panggil | No. Barkod | Ketersediaan |
---|---|---|
S64473 | TERSEDIA |
Ulasan: |
Tidak ada ulasan pada koleksi ini: 20431685 |