Analisis pengurangan energi arc flash dengan optimasi koordinasi alat proteksi pada instalasi listrik di lapangan migas lepas pantai = Analysis of arc flash energy reduction by optimizing protection device coordinaton at electrical installation in offshore oil fied / Atas Siregar
Siregar, Atas;
Iwa Garniwa M.K., supervisor; Rudy Setiabudy, examiner; Amien Rahardjo, promotor; I Made Ardita Y., examiner
([Publisher not identified]
, 2016)
|
ABSTRAK Keselamatan dari bahaya arc flash telah menjadi persyaratan dalam pengoperasiansuatu instalasi listrik di lapangan migas lepas pantai. Kejadian arc flash tidak hanyamengancam keselamatan pekerja dan fasilitas tersebut tetapi juga bisa mengakibatkankegagalan produksi yang sangat mahal. Salah satu cara untuk mengurangi bahaya arc flashini ialah menurunkan trip setting alat proteksi sehingga alat proteksi bisa berkerja secepatmungkin untuk menghilangkan kejadian arc flash. Namun penurunan trip setting alat proteksiini harus optimal sehingga tetap bisa menjamin kehandalan alat proteksi terhadap ganguan,selain juga bisa mengurangi energi arc flash. Pada penelitian ini dilakukan analisispengurangan energi arc flash dengan mengoptimasi koordinasi alat proteksi pada instalasilistrik di lapangan ABC, sebuah lapangan migas lepas pantai di Laut Natuna. Hasil analisismemperlihatkan energi arc flash system bisa dikurangi sampai batas yang diperbolehkantanpa mengorbankan kehandalan alat proteksi terhadap gangguan. Pada bagian akhirdipaparkan analisis ekonomi yang memperlihatkan pengurangan energi arc flash denganoptimasi koordinasi alat proteksi di lapangan migas ABC dapat diterima secara bisnis karenamemberikan keuntungan yaitu mengurangi biaya tidak tetap akibat kejadian arc flash denganNPV (Net Present Value) sebesar USD 675.932. ABSTRACT Electrical safety from arc flash hazard has become requirement for operation of anoffshore oil platform. During it?s operation, arc flash is always become potential hazard thatnot only threaten personal and facility safety, but also can cause very expensive productionloss. One solution to reduce arc flash hazard is reducing protection device trip setting tomake it working faster to isolate fault. But reducing protection devices shall be optimum thatit shall be able to maintain reliability from inadvertant trip as well as reducing arc flashenergy. In this research, analysis of arc flash reduction by optimizing protection devicecoordination will be conducted at electrical instalation in field ABC, offshore oil platform inLaut Natuna. Study result shows optimizing protection device setting can reduce arc flashincident energy till meet allowable limit without sacrifice realiability of power supply. At theend, economical analysis is also carried out that shows above investment can be accepted dueto give benefit for preventing loss due to arc flash equivalent with cost NPV (Net PresentValue) USD 675.932. |
T45753-Atas Siregar.pdf :: Unduh
|
No. Panggil : | T45753 |
Entri utama-Nama orang : | |
Entri tambahan-Nama orang : | |
Entri tambahan-Nama badan : | |
Subjek : | |
Penerbitan : | [Place of publication not identified]: [Publisher not identified], 2016 |
Program Studi : |
Bahasa : | ind |
Sumber Pengatalogan : | LibUI ind rda |
Tipe Konten : | text |
Tipe Media : | unmediated ; computer |
Tipe Carrier : | volume ; online resource |
Deskripsi Fisik : | xvi, 112 pages : illustration ; 28 cm + appendix |
Naskah Ringkas : | |
Lembaga Pemilik : | Universitas Indonesia |
Lokasi : | Perpustakaan UI, Lantai 3 |
No. Panggil | No. Barkod | Ketersediaan |
---|---|---|
T45753 | 15-17-669471722 | TERSEDIA |
Ulasan: |
Tidak ada ulasan pada koleksi ini: 20432430 |