Evaluasi penerapan keselamatan kebakaran pada jenis bangunan komersial studi kasus: kawasan rumah toko/rumah kantor deret di kota x tahun 2016 = Evaluation implementation of fire safety at shophouse building in district x year 2016 abstract / Ida Ayu Indira Dwika Lestari

Ida Ayu Indira Dwika Lestari; Fatma Lestari, supervisor; Dadan Erwandi, examiner; Pangaribuan, Adrianus, examiner; Muhammad Dawaman, examiner ([Publisher not identified] , 2016)

 Abstrak

ABSTRAK
Penelitian bertujuan untuk evaluasi penerapan keselamatan kebakaran pada bangunan rumah toko/rumah kantor PT ABC, mengetahui nilai ketahanan bangunan rumah toko/rumah kantor PT ABC jika terjadi kebakaran pada bangunan tersebut, memberikan rekomendasi perbaikan fasilitas kebakaran pada bangunan rumah toko/rumah kantor PT ABC, serta mengetahui nilai keselamatan kebakaran bangunan rumah toko/rumah kantor berdasarkan berdasarkan kesesuaian 12 safety parameter dan persyaratan tambahan pada NFPA 101A: Alternative Approaches to Life Safety dan standar NFPA 101: Life Safety Code. Penelitian mengambil sampel kluster rumah toko/rumah kantor di koridor jalan KH Soleh iskandar,berdasarkan kriteria-kriteria yang telah ditetapkan. Data dianalisis dengan menggunakan analisis deskriptif kualitatif dengan bantuan tools CFSES. Hasil penelitian menunjukkan bahwa ketersediaan unsur keselamatan kebakaran pada bangunan rumah toko/rumah kantor yang ditempati oleh PT ABC dikawasan X belum sesuai dengan standar NFPA 101 berdasarkan tools CFSES. Rekomendasi yang diberikan diharapkan bangunan rumah toko/rumah kantor dimasa yang akan datang dapat memenuhi aspek sarana penyelamatan dengan berbagai alternatif jalur keselamatan untuk mencegah jatuhnya korban jiwa saat kebakaran serta unsur keselamatan

ABSTRACT
The point of this study is to evaluate the implementation of fire safety at the shophouses building of PT.ABC, to measure the resistency of the building to fire, to provide recommendation of repairment fire facility in the building, and also to measure the value of fire safety at shophouse building PT ABC is based on the basis of suitability 12 safety parameters and additional requirements in NFPA 101A: Alternative Approaches to Life Safety and standard NFPA 101: Life Safety Code. The writer set a cluster shophouse at KH Soleh Iskandar street corridor as sample for this study based on the criteria that have been set. Data were analyzed using qualitative descriptive analysis with the help of tools CFSES. The results showed that the availability of fire safety on the shophouse building occupied Is not comply with NFPA 101 standar.Design shophouse building for the future must apply the standard means of rescue with a variety of alternative safety measure to prevent the loss of lives when fires and other safety elements.

 File Digital: 2

Shelf
 T46249-Ida Ayu Indira Dwika Lestari.pdf :: Unduh
 T46249-Ida Ayu Indira Dwika Lestari.pdf :: Unduh

LOGIN required

 Metadata

No. Panggil : T46249
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Subjek :
Penerbitan : [Place of publication not identified]: [Publisher not identified], 2016
Program Studi :
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : unmediated ; computer
Tipe Carrier : volume ; online resource
Deskripsi Fisik : xix, 121 pages : illustration ; 28 cm + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
No. Panggil No. Barkod Ketersediaan
T46249 15-17-151171583 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20432661