:: UI - Tesis Membership :: Kembali

UI - Tesis Membership :: Kembali

Penilaian pajanan tekanan panas di workshop pembuatan batik PT X tahun 2016 = Exposure assessment of heat stress at batik workshop PT X year 2016 / Rumiris Feronika Simaremare

Simaremare, Rumiris Feronika; Chandra Satrya, supervisor; Zulkifli Djunaidi, examiner; Indri Hapsari Susilowati, examiner; Trisnajaya, examiner; Masjuli, examiner ([Publisher not identified] , 2016)

 Abstrak

ABSTRAK
Tujuan dari penelitian ini adalah melakukan penilaian terhadap pajanan tekanan panas
di workshop pembuatan batik yang terletak di Kecamatan Mauk, Tangerang.
Sebanyak 84% dari pekerja yang diwawancarai mengeluh tentang suhu lingkungan
kerja yang dirasa terlalu panas, meskipun dalam hal ini sudah terdapat pengendalian
terhadap tekanan panas yang terpasang pada bangunan. Penilaian didasarkan pada tiga
kriteria menurut Worksafe BC 2007, yakni faktor lingkungan, faktor pekerja, dan
faktor pekerjaan. Hasil penelitian menunjukkan bahwa Indeks Suhu Basah dan Bola
(ISBB) di luar ruangan (outdoor) lebih tinggi dibanding ISBB di dalam ruangan
(indoor) dan indeks panas berada pada area berbahaya dengan level risiko tinggi.
Hasil observasi faktor pekerja yang meliputi aklimatisasi, status hidrasi dan pakaian
kerja tidak menunjukkan adanya upaya pengendalian yang dilakukan. Demikian juga
hasil observasi pada faktor pekerjaan yakni beban kerja dan pola kerja tidak
menunjukkan adanya pengendalian administratif yang diupayakan dalam menangani
keluhan terhadap pajanan tekanan panas ini. Penurunan tingkat risiko pajanan tekanan
panas diharapkan dapat dilakukan dengan modifikasi pengendalian teknis,
mengupayakan pengendalian administratif serta penggunaan pakaian kerja yang
sesuai dengan lingkungan kerja dengan pajanan tekanan panas

ABSTRACT
The aim of this study was to make an assessment of the heat stress exposure in a Batik
Workshop located at Kecamatan Mauk, Tangerang. 84% of interviewed workers
complained about the working environment temperature that tends to be very hot,
although the building already has a built-up control to heat stress. The assessment is
based on three criteria by Worksafe BC 2007 that is environmental, worker, and work
factors. The result showed that the Wet Bulb Globe Temperature (WBGT) outdoor
higher than indoor, and the heat index is at dangerous area with a high risk level.
Observation on worker (acclimatization, hydratin and clothing) and work (work load
and work rate) factors did not show any control measures undertaken. The level of
risk can be reduced by modification of engineering control, administrative control and
the proper personal protective equipment (clothing).

 File Digital: 1

Shelf
 T46391-Rumiris Feronika Simaremare.pdf :: Unduh

LOGIN required

 Metadata

No. Panggil : T46391
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Subjek :
Penerbitan : [Place of publication not identified]: [Publisher not identified], 2016
Program Studi :
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : unmediated ; Computer (rdadontent)
Tipe Carrier : volume ; online resource
Deskripsi Fisik : xviii, 111 pages : illustration ; 28 cm + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
No. Panggil No. Barkod Ketersediaan
T46391 15-18-052204328 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20433159