Analisis kegagalan peralatan dan optimasi proses sweetening di lapangan x = Equipment failure analysis and sweetening process optimization at field x / Rio Kurniawan

Rio Kurniawan; Slamet, supervisor; Sutrasno Kartohardjono, examiner; Yuswan Muharam, examiner; Mohammad Nasikin, examiner ([Publisher not identified] , 2016)

 Abstrak

ABSTRAK
Lapangan X memiliki gas dengan kandungan CO2 > 20% dan harus dikurangi menjadi 5% dikarenakan CO2 mempengaruhi heating value gas, toxicity dan sangat korosif. Proses pemurnian gas yang dilakukan adalah absorbsi CO2 dari gas alam menggunakan larutan activated methyldiethanolamine. Sejak beroperasinya unit CO2 removal di Lapangan X tahun 2003, telah mengalami kegagalan, yaitu 3 kali kerusakan pada peralatan CO2 removal, dimana terjadi penipisan pada dinding absorber dan kerusakan pada tray di low pressure flash, serta gas yang akan dijual masih di atas 5% sehingga dilakukan identifikasi terhadap kegagalan pada unit peralatan CO2 dengan melakukan survey lapangan dan pengujian di laboratorium, serta analisis proses CO2. menggunakan simulasi HYSYS. Hasil analisis data laboratorium menunjukkan kegagalan pada peralatan dapat disebabkan karena korosi CO2, Cl- dan beban mekanik, sedangkan pada simulasi, kegagalan disebabkan oleh tidak efektifnya proses absorbsi CO2, dimana sulitnya mengatur temperatur regenerasi amine yang berdampak pada temperatur lean amine sehingga regenerasi CO2 tidak sempurna yang menyebabkan tingginya CO2 pada outlet gas absorber, acid loading, dan loses amine & H2O. Oleh karena itu perlu dilakukan optimasi proses absorbsi CO2 di Lapangan X, dengan penambahan cooler setelah LP flash sehingga temperatur regenerasi dapat mencapai 90 oC dengan tetap menjaga temperatur lean amine pada 50-60 oC. Konsentrasi amine yang dapat digunakan sekitar 40 ? 50 wt% dan flowrate amine sekitar 700 ? 1083 m3/h.

ABSTRACT
Field X produces nature gas which content CO2 more than 20% and should be reduced to be less than 5%. CO2 very affects to the gas heating value, toxicity, and its corrosive level. Field X does absorption process to purify natural gas from CO2 using activated methyldiethanolamine. Since the establishment of CO2 removal unit at Field X, the equipment for CO2 absorption process has been damaged three times, in example depletion of the absorber wall and damage to the tray at low pressure flash. Besides, the gas has not met the specification yet, which is CO2 level above 5%. According to the situation described, we need to identify the cause of CO2 equipment unit failure trough some field research, lab testing, and analysis CO2 process using HYSYS simulation. Lab test result shows equipment failure can be caused by CO2 corrosion, Cl- and mechanical load, while simulation result shows this failure can be caused by CO2 absorption process. The difficulty to set amine regeneration temperature will impact to lean amine temperature so that CO2 regeneration process not complete and cause the high value of CO2 in absorber outlet gas, acid loading, and loses amine and H2O. Therefore we need to do optimization for CO2 absorption process in Field X, such as adding a cooler after LP Flash so regeneration temperature reach 90˚C but still keep the lean amine temperature in 50 ? 60˚C. Amine concentration that can be used around 40-50 wt% and amine flowrate around 700 ? 1083 m3/h.;

 File Digital: 1

Shelf
 T46656-Rio Kurniawan.pdf :: Unduh

LOGIN required

 Metadata

No. Panggil : T46656
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Subjek :
Penerbitan : [Place of publication not identified]: [Publisher not identified], 2016
Program Studi :
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : unmediated ; computer
Tipe Carrier : volume ; online resource
Deskripsi Fisik : xvi, 104 pages : illustration ; 28 cm + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
No. Panggil No. Barkod Ketersediaan
T46656 15-18-003956867 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20433726