:: UI - Tesis Membership :: Kembali

UI - Tesis Membership :: Kembali

Perbandingan prediktabilitas refraksi biometri optikal dengan dan tanpa sikloplegik pada pasien pasca fakoemulsifikasi dan implantasi lensa intraokular = Comparison of refractive predictability optical biometry before and after cycloplegia in patients after phacoemulsification and intraocular lens implantation / Simon Alberti Siregar

Siregar, Simon Alberti; Yudisianil Eshaputra Kamal, examiner; Amir Shidik, examiner; Umar Mardianto, examiner; Herqutanto, examiner ([Publisher not identified] , 2016)

 Abstrak

ABSTRAK
Tujuan Membandingkan prediktabilitas refraksi pasca operasi katarak pada pasien yang telah dilakukan pemeriksaan kekuatan LIO menggunakan biometri optikal dengan dan tanpa sikloplegik.
Desain
Penelitian ini merupakan uji kuasi eksperimental 2 kelompok yang tidak berpasangan.
Metode
Sebanyak 34 mata dari 25 subjek penelitian dengan katarak senilis imatur yang memiliki axial length (AXL) 22-24.5 mm dilakukan pemeriksaan optikal tanpa dan dengan sikloplegik pada mata yang sama sebelum dilakukan operasi fakoemulsifikasi dengan implantasi lensa intraokular (LIO). Data pemeriksaan biometri optikal tanpa dan dengan sikloplegik merupakan dua kelompok tidak berpasangan. Lensa intraokular yang diimplantasikan kepada subjek penelitian ditentukan berdasarkan target refraksi minus terkecil pada mata tanpa pengaruh sikloplegik. Perhitungan power LIO dilakukan dengan menggunakan formula Haigis. LIO yang digunakan adalah 1 jenis berbahan akrilik foldable. Prediktabilitas refraksi dihitung berdasarkan selisih antara spherical equivalent (SE) pasca operasi 3 minggu dengan target refraksi pada masing-masing kelompok dalam nilai absolut.
Hasil
Rerata prediktabilitas refraksi pada kelompok tanpa sikloplegik 0,37 ± 0,22, sedangkan median kelompok dengan sikloplgeik 0,4 (0,04-1,21). Proporsi prediktabilitas refraksi pada kelompok dengan sikloplegik < 0,5 D adalah 70,6%, sedangkan kelompok dengan sikloplegik adalah 73,5%.
Kesimpulan
Prediktabilitas refraksi dan proporsi prediktabilitas refraksi dengan menggunakan rumus Haigis pada mata dengan AXL normal tidak berbeda signifikan secara statistik antara masing-masing kelompok penelitian

ABSTRACT
Aim Comparing the refractive predictability after cataract surgery in patients who undergo intraocular lens (IOL) calculation with and without effect of cycloplegia using optical biometry.
Design
This study is a quasi-experimental test of two unpaired groups.
Method
A total of 34 eyes from 25 subjects with immature senile cataract which has axial length 22-24.5 mm underwent intraocular lens (IOL) calculation with and without effect of cycloplegia using optical biometry before phacoemulsification and IOL implantation. The result data were separated into ?without cycloplegia? (first) group and ?with cycloplegia? (second) group. Implanted intraocular lenses were determined by the lowest myopic spheroequivalent residual refraction from the eye without effect of cycloplegia. Intraocular lens calculation were performed by using the Haigis formula. Intraocular lens used were made of acrylic foldable. Refractive predictability is calculated based on the difference between the refraction spherical equivalent (SE) 3 weeks postoperatively and target refraction for each group in absolute value.
Result
The refractive predictability mean in the first group is 0.37 ± 0.22, while the second group median is 0.4 (0.04 to 1.21). Proportion of refractive predictability in the first group <0.5 D is 70.6%, while the second group is 73.5%.
Conclusion
Refractive predictability and proportion of refractive predictability using the Haigis formula in eyes with normal AXL did not differ statistically significant between the respective research groups.

 File Digital: 1

Shelf
 T-Simon Alberti Siregar.pdf :: Unduh

LOGIN required

 Metadata

No. Panggil : T-Pdf
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Subjek :
Penerbitan : [Place of publication not identified]: [Publisher not identified], 2016
Program Studi :
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : computer
Tipe Carrier : online resource
Deskripsi Fisik : xv, 90 pages : illustration ; 28 cm + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
No. Panggil No. Barkod Ketersediaan
T-Pdf 15-18-295695113 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20433748