:: UI - Skripsi Open :: Kembali

UI - Skripsi Open :: Kembali

Kontaminasi bakteri Escherichia coli pada produk depot air minum isi ulang di Kecamatan Pancoran Mas, Depok, Tahun 2009 = The Escherichia coli contamination of water refilling station product in Pancoran Mas Subdistrict, Depok, Year 2009

Tegar Rezavie Ramadhan; Sri Tjahjani Budi Utami, supervisor; Zakianis, examiner; Rina Fithri Anni Bahar, examiner (Fakultas Kesehatan Masyarakat Universitas Indonesia, 2009)

 Abstrak

Permintaan terhadap air minum dalam kemasan semakin meningkat. Hal ini menjadi masalah dengan ditemukannya kontaminasi fekal coli pada produk depot air minum isi ulang di Kota Depok. Walaupun demikian, penelitian yang ada belum meneliti bakteri indikator kontaminasi fekal manusia, Escherichia coli. Selain itu, faktorfaktor yang kemungkinan mempengaruhi kontaminasi juga belum diteliti. Untuk itu, penelitian ini dilakukan untuk mengetahui gambaran kontaminasi Escherichia coli di depot air minum isi ulang dan faktor yang kemungkinan berhubungan dengan terjadinya kontaminasi, yaitu higiene perorangan operator serta sanitasi lingkungan depot air minum. Penelitian yang dilakukan bersifat kuantitatif deskriptif dengan mengambil sampel sebanyak 21 depot di Kecamatan Pancoran Mas, Depok. Jumlah E. coli dienumerasi dengan teknik MPN. Sedangkan higiene perorangan dan sanitasi lingkungan dikuantifikasi dengan skoring. Hasil penelitian menemukan bahwa dari 21 depot yang diteliti ada dua depot (9.5%) terkontaminasi Escherichia coli. Depot yang terkontaminasi masing-masing terletak di wilayah kerja Puskesmas Cipayung dan Depok Jaya. Hasil observasi mengindikasikan bahwa sanitasi lingkungan kemungkinan lebih berpengaruh terhadap terjadinya kontaminasi pada air minum bila dibandingkan dengan higiene perorangan. Untuk itu peneliti menyarankan agar pengusaha melengkapi sarana dan prasarana sanitasi serta menjaga kebersihan DAMIU miliknya.

The demand of packaged water products is increasing. This create problems as the findings of fecal contamination on those water refilling station packaged water products is becoming often in Depok. Even so, the previous research have not examine human faecal bacteria indicator, Escherichia coli. Some more the factors that have influence to contaminate have not examine too. Therefore, this research is conducted to projects the Escherichia coli contamination on the products along with its risk, personal hygiene and environment sanitation. This is a quantitative descriptive research that acquires sample from 21 depot in Pancoran Mas Subdistrict, Depok. Quantity of E. coli was enumerated by MPN. Whereas personal hygiene and enviroment sanitation was quantified by scoring. Research detects the Escherichia coli contamination on two (9.5%) the sample products from 21 samples was taken. Contaminated depot reside in Puskesmas Cipayung and Depok Jaya working area. Observation indicate that environment sanitation have higher possibility to contaminate water product than personal hygiene. Therefore, researcher suggest to water refilling enterpriser for completing sanitation infrastructure and keep clean their the water refilling station.

 File Digital: 1

 Metadata

No. Panggil : S-Pdf
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Subjek :
Penerbitan : Depok: Fakultas Kesehatan Masyarakat Universitas Indonesia, 2009
Program Studi :
Bahasa : ind
Sumber Pengatalogan : LibUI ita rda
Tipe Konten : text
Tipe Media : computer
Tipe Carrier : online resource
Deskripsi Fisik : xiv, 79 pages : illustration ; 28 cm + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
No. Panggil No. Barkod Ketersediaan
S-Pdf 14-24-70780513 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20439517