Pemodelan mikromekanik pada komposit carbon nano tube/polydimethylsiloxane untuk aplikasi wireless electrode = Micromodelling of carbon nano tube/polydimethylsiloxane for wireless electrode application
Muhammad Reza Alfin;
Yudan Whulanza, supervisor; Ario Soeryo Baskoro, examiner; Agus Sunjarianto Pamitran, examiner; Sugeng Supriadi, examiner; Ardiansyah, examiner
([Publisher not identified]
, 2015)
|
ABSTRAK Dalam pengembangan teknologi di dunia medis, pemantauan kesehatan secara konstan danberkesinambungan yang dilakukan secara realtime merupakan salah satu parameter utamatercapainya keberhasilan dalam proses penyembuhan pasien.Namun hingga saat ini masihterdapat berbagai kendala seperti degradasi kualitastransfer pembacaan sinyal elektrik olehelektroda konduktif hingga yang bersifat biologis seperti iritasi pada kulit jika dilakukanpemantauan jangka panjang. Salah satu solusi untuk mengatasi hal tersebut ialah denganmelakukan substitusi terhadap material bioelektroda Ag/AgCl yang telah digunakan secarakonvensional dengan bioelektrodacampuran Polydimethylsiloxane (PDMS) dan CarbonNanotube (CNT) yang memiliki tingkat fleksibilitas mekanik maupun parameterbiodegradabilitas yanglebih baik. Pada penelitian ini telah dilakukan proses fabrikasikomposit PDMS dengan material filler penguat berupa Carbon Nanotube Berdinding Tunggal(SWCNT) dengan perbedaan variabel konsentrasi sebesar 3%, 5%, dan 7%. Didapatkanbahwa saat dilakukan proses karakterisasi mekanik modulus elastisitas (E) dari kompositdengan prosedur uji tarik mikro, besarnya peningkatan konsentrasi CNT berpengaruh padanilai modulus, dengan rincian pada spesimen awal ialah sebesar 1,794 MPa dan mengalamipeningkatan signifikan menjadi 3,149 MPa lalu tingkat kenaikannya melemah menjadi 3,27MPa. Pemodelan analitik mikromekanik juga telah dilakukan mencakup pemodelan aturanpencampuran Voigt dan Reuss, hingga pemodelan Halpin-Tsai yang lebih kompleks ABSTRACT The development in the medical technology area, a constant and continous health monitoringperformed in real time is one of the main parameters to achieve success in the healing processof the patient. But until now there are still many obstacles such as the degradation of thequality of the reading transfer using electrical signals by conductive electrodes to thebiological problem such as irritation to the skin if done on long-term monitoring. Onesolution to overcome this problem is to conduct the substitution of the bioelectrode materialof Ag / AgCl which has been used conventionally with a novel bioelectrode, a mixture ofPolydimethylsiloxane (PDMS) and Carbon Nano Tube (CNT) which has a better qualityinmechanical flexibility and biodegradability parameters. This study has been conducted withfabrication PDMS composite and its reinforcing filler material in the form of Single-WalledCarbon Nano Tube (SWCNT) with the difference of concentrations variable consist 3%, 5%and 7%. We report that when the process is carried out the mechanical characterization of themodulus of elasticity (E) of the composite with micro tensile test procedure, the amount ofincrease in the concentration of CNTs cause an effect on the value of modulus, with detailson the first specimen is at 1.794 MPa and increased significantly to 3,149 MPa, then the ratesof increase weakened to 3.27 MPa. Analytic modeling micromechanical modeling has alsobeen covered include Voigt and Reuss model which known as aRules of Mixture, and morecomplex model such as Halpin-Tsai model |
S65100-Muhammad reza alfin .pdf :: Unduh
|
No. Panggil : | S65100 |
Entri utama-Nama orang : | |
Entri tambahan-Nama orang : | |
Entri tambahan-Nama badan : | |
Subjek : | |
Penerbitan : | [Place of publication not identified]: [Publisher not identified], 2015 |
Program Studi : |
Bahasa : | ind |
Sumber Pengatalogan : | LibUI ind rda |
Tipe Konten : | text |
Tipe Media : | unmediated ; computer |
Tipe Carrier : | volume ; online resource |
Deskripsi Fisik : | xii, 46 pages : illustration ; 29 cm + appendix |
Naskah Ringkas : | |
Lembaga Pemilik : | Universitas Indonesia |
Lokasi : | Perpustakaan UI, Lantai 3 |
No. Panggil | No. Barkod | Ketersediaan |
---|---|---|
S65100 | 14-18-861375097 | TERSEDIA |
Ulasan: |
Tidak ada ulasan pada koleksi ini: 20441963 |