:: Artikel Jurnal :: Kembali

Artikel Jurnal :: Kembali

Penentuan recovery dan limit deteksi unsur kadmium, kobalt, tembaga, mangan, nikel, molibdenum dan timbal pada uranium oksida menggunakan spektrofotometer serapan atom / Deni Mustika, Asminar, Rahmiati, Torowati

Deni Mustika (Pusat Teknologi Bahan Bakar Nuklir Badan Tenaga Nuklir Nasional, 2016)

 Abstrak

Telah dilakukan Penentuan Recovery dan Limit Deteksi Unsur Kadmium, Kobalt, Tembaga, Mangan, Nikel, Molibdenum dan Timbal pada Uranium Oksida Menggunakan Spektrofotometer Serapan Atom - flame yang didahului dengan proses ekstraksi menggunakan TBP, TBP + CCL4 20 % dan CCL4. Validasi metode dilakukan untuk menentukan unjuk kerja suatu metode pengujian yang dikembangkan diantaranya perolehan kembali (recovery) dan limit deteksi. Penelitian ini bertujuan menentukan perolehan kembali (recovery) dan limit deteksi unsur Cd, Co, Cu, Mn, Ni, Mo dan Pb dalam Uranium Oksida (U3O8) menggunakan alat spektrofotometer serapan atom - flame yang didahului dengan proses ekstraksi menggunakan TBP, TBP + CCL4 20 % dan CCL4. Pada penelitian ini Uranium Oksida dilarutkan dengan HNO3, dilakukan ekstraksi menggunakan TBP, TBP + CCl4 20 % dan CCL4, selanjutnya fase air dalam asam encer dianalisis menggunakan SSA ? flame, recovery ditentukan dengan metode adisi (spike). Diperoleh persentase recovery antara 81,84 % hingga 113 %, penurunan persentase recovery menunjukkan adanya kehilangan analit selama berlangsungnya proses preparasi, kenaikan persentase recovery menandakan adanya penambahan analit yang berasal dari pelarut atau ekstraktan selama proses preparasi. Limit deteksi pengujian yang diperoleh adalah antara 0,0021 mg/L dan 0,8998 mg/L, lebih tinggi dibanding limit deteksi instrumen.
Studies on the determination recovery and detection limit of Cadmium, Cobalt, Copper, Manganese, Nickel, Molybdenum and Lead in Uranium Oxide using Atomic Absorption Spectrophotometer - Flame are described. A method developed should be validated to verify its performance parameter. The studies aim to determine the recovery and detection limit of Cadmium, Cobalt, Copper, Manganese, Nickel, Molybdenum and Lead in Uranium Oxide using Atomic Absorption Spectrophotometer ? Flame. In this study, the bulk of the matrix is dissolved with nitric acid and separated by batch extraction using TBP, TBP +CCl4 20 % and CCL4. The final aqueous phase containing the metallic impurities is fed to AAS ? flame, the recovery is determined by spike method. It is found that the recovery for various elements is in range 81,84 % - 113 % while the limit of detection for various elements is in range 0.0021 mg/L ? 0.8998 mg/L.

 File Digital: 1

 Metadata

No. Panggil : 620 PIN 9:17 (2016)
Entri tambahan-Nama orang :
Subjek :
Penerbitan : [Place of publication not identified]: Pusat Teknologi Bahan Bakar Nuklir Badan Tenaga Nuklir Nasional, 2016
Sumber Pengatalogan : LibUI ind rda
ISSN : 19792409
Majalah/Jurnal : PIN Pengelolaan Instalasi Nuklir
Volume : Vol. 9, No. 17, Oktober 2016: Hal. 12-21
Tipe Konten : text
Tipe Media : unmediated ; computer
Tipe Carrier : volume ; online resource
Akses Elektronik : http://jurnal.batan.go.id/index.php/pin/article/view/3310/2935
Institusi Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 4, R. Koleksi Jurnal
  • Ketersediaan
  • Ulasan
No. Panggil No. Barkod Ketersediaan
620 PIN 9:17 (2016) TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20449733