Studi penerapan high pass damped filter, static var compensator dan dynamic voltage restorer untuk kehandalan sistem distribusi listrik = Study of application of high pass filter damped, static var compensator and dynamic voltage restorer for electrical distribution system reliability / Muhammad Asrul Fahrul
Muhammad Asrul Fahrul;
Iwa Garniwa M.K., supervisor; Ridwan Gunawan, examiner; Chairul Hudaya, examiner; Amien Rahardjo, examiner
([Publisher not identified]
, 2017)
|
ABSTRAK Perkembangan yang cukup pesat dalam bidang teknologi elektronika daya telah memungkinkan kita untuk mengurangi gangguan kinerja dalam suatu sistem ketenagalistrikan. Antara harmonisa dan kualitas tegangan yang ada dalam dunia industri, dapat dianggap sebagai sebuah masalah yang paling penting untuk beban yang sensitive dan keberlangsungan suatu industri. Dynamic Voltage Restrore DVR adalah suatu perangkat elektronika daya berbasis seri yang dapat dengan cepat dapat mengembalikan dan memperbaiki profil tegangan sistem dengan berbagai bentuk nilai pra-kesalahan. Kebutuhan jaringan distribusi, beban industri sensitif dan operasi komersil yang kritis semua dapat mengalami gangguan kinerja dan sebuah cara sistematis dapat digunaan untuk mengatasi gangguan yang diklasifikasikan dalam masalah yang berkaitan dengan kualitas tegangan. Instalasi Dynamic Voltage Restore DVR dan Static Var Compensator serta High Pass Damped Filter adalah salah satu dari solusi penghematan biaya untuk permasalahan kualitas tegangan listrik dan sejenisnya. Tujuan dasar dari penelitian ini untuk membandingkan, menganalisis model dan kinerja dari perangkat DVR, SVC dan High Pass Damped Filter dalam tinjauan kehandalan sistem ketenagalistrikan dalam suatu jaringan sistem distribusi listrik dalam berbagai kondisi dan variasi beban linear dan non linear. Kinerja dan efisiensi metoda yang diusulkan akan diselidiki dengan simulasi di program ETAP dan MATLAB. Kata Kunci: Kualitas Tegangan, Harmonisa, DVR, SVC, High Pass Damped Filter. ABSTRACT The development of a fairly rapidly in the field of power electronics technology has enabled us to reduce impaired performance in a system ketenagalistrikan. Between harmonic distortion and voltage quality that exists in the world of industry, can be considered as a most important issue for the sensitive loads and the sustainability of an industry. Dynamic Voltage Restrore DVR is a power electronics based series that can quickly be able to restore and improve voltage profile systems with different forms of pre value error. The needs of the distribution network, load sensitive industries and commercial operations that are critical can all crash performance and a systematic manner can only to overcome disorders classified in issues related to the quality of voltage. Installation of Dynamic V oltage Restore DVR and Static V ar Compensator and High Pass Filter are Damped one of the cost saving solution for voltage quality problems and the like. The basic purpose of this research was to compare, analyse and model the performance of the DVR, SVC and High Pass Filter in Damped views dependability system in a network of electrical distribution systems in a variety of linear and non linear load variations conditions. The performance and efficiency of the proposed method will be investigated with a simulation program of ETAP and MATLAB. Key Words Quality of Voltage, Harmonic Distortion, DVR, SVC, High Pass Filter Damped |
T48780-Muhammad Asrul Fahrul.pdf :: Unduh
|
No. Panggil : | T48780 |
Entri utama-Nama orang : | |
Entri tambahan-Nama orang : | |
Entri tambahan-Nama badan : | |
Subjek : | |
Penerbitan : | [Place of publication not identified]: [Publisher not identified], 2017 |
Program Studi : |
Bahasa : | ind |
Sumber Pengatalogan : | LibUI ind rda |
Tipe Konten : | text |
Tipe Media : | unmediated ; computer |
Tipe Carrier : | volume ; online resource |
Deskripsi Fisik : | xv, 147 pages : illustration ; 28 cm + appendix |
Naskah Ringkas : | |
Lembaga Pemilik : | Universitas Indonesia |
Lokasi : | Perpustakaan UI, Lantai 3 |
No. Panggil | No. Barkod | Ketersediaan |
---|---|---|
T48780 | 15-18-485874552 | TERSEDIA |
Ulasan: |
Tidak ada ulasan pada koleksi ini: 20454362 |