Sensitivitas, spesifisitas, dan akurasi pemeriksaan kramer terhadap neonatal jaundice: perbandingan dengan total serum bilirubin = Sensitivity specificity and accuracy of kramer examination to neonatal jaundice comparison with total serum bilirubin
Zesi Aprillia;
Fajar Tri Waluyanti, supervisor; Dewi Gayatri, supervisor; Yeni Rustina, examiner; Yanti Riyantini, examiner
([Publisher not identified]
, 2017)
|
ABSTRAK Neonatal jaundice sering terjadi pada minggu pertama awal kehidupan bayi setelah lahir. Deteksi dini neonatal jaundice dapat mencegah terjadinya kernikterus sebagai komplikasi tingginya kadar bilirubin pada neonatus. Visual assessment merupakan salah satu pemeriksaan untuk menilai neonatal jaundice yang diperkenalkan oleh Kramer. Tujuan penelitian ini adalah mengetahui nilai sensitivitas, spesifitas dan akurasi visual assessment atau pemeriksaan Kramer pada neonatal jaundice. Penelitian ini menggunakan desain cross sectional pada 102 bayi dengan teknik pengambilan sampel consecutive sampling. Analisis data dilakukan dengan tabel uji diagnostik 2x2. Hasil penelitian ini menunjukkan bahwa visual assessment pada neonatal jaundice nilai sensitivitas 76,92 , spesifisitas 89,47 , dan nilai akurasi 86,27 . Penelitian ini dapat menjadi informasi untuk pengembangan pemeriksaan noninvasif lainnya dalam menilai neonatal jaundice untuk menurunkan angka mobiditas neonatus. Kata Kunci: akurasi, neonatal jaundice, sensitivitas, spesitifitas, visual assessment ABSTRACT Neonatal jaundice often occurs in the first week after birth. Early detection of neonatal jaundice can prevent kernicterus as a complication of high levels of bilirubin in neonates. Visual assessment is one of the examinations to assess the neonatal jaundice introduced by Kramer. The purpose of this study was to determine the sensitivity, specificity and accuracy of visual assessment or Kramer examination in neonatal jaundice. This study used cross sectional design to examine 102 babies as the sample which was selected by convenience sampling method. 2x2 table diagnostic test was employed in this study to analyze the data. The results of this study showed that visual assessment in neonatal jaundice had sensitivity valued 76.92 , specificity valued 89.47 , and accuracy valued 86.27 . This research can be acknowledged for the development of other non invasive examinations in assessing neonatal jaundice for decreasing the number of neonatal morbidity. Keywords accuracy, neonatal jaundice, sensitivity, specificity, visual assessment |
![]()
|
No. Panggil : | T47657 |
Entri utama-Nama orang : | |
Entri tambahan-Nama orang : | |
Entri tambahan-Nama badan : | |
Subjek : | |
Penerbitan : | [Place of publication not identified]: [Publisher not identified], 2017 |
Program Studi : |
Bahasa : | ind |
Sumber Pengatalogan : | LibUI ind rda |
Tipe Konten : | text |
Tipe Media : | unmediated ; computer |
Tipe Carrier : | volume ; online resource |
Deskripsi Fisik : | xv, 96 pages : illustration ; 28 cm + appendix |
Naskah Ringkas : | |
Lembaga Pemilik : | Universitas Indonesia |
Lokasi : | Perpustakaan UI, Lantai 3 |
No. Panggil | No. Barkod | Ketersediaan |
---|---|---|
T47657 | 15-20-886989603 | TERSEDIA |
Ulasan: |
Tidak ada ulasan pada koleksi ini: 20454842 |