:: UI - Tesis Membership :: Kembali

UI - Tesis Membership :: Kembali

Penetapan kadar asam folat serum dengan teknik enzyme labeled protein ligand binding assay yang disempurnakan = Determination of serum folic acid concentration using improved enzyme labeled protein ligand binding assay

Muhamad Arif Budiman; Ani Retno Prijanti, supervisor; Mohamad Sadikin, supervisor; Dwirini Retno Gunarti, examiner; Harahap, Alida Roswita, examiner; Frans Ferdinal, examiner (Fakultas Kedokteran Universitas Indonesia, 2017)

 Abstrak

Latar Belakang. Penelitian ini bertujuan untuk membakukan teknik pengukuran asam folat serum menggunakan protein ikat folat PIF yang diisolasi dan dimurnikan secara utuh dari susu sapi segar dengan teknik enzyme labeled protein ligand binding assay ELPLBA . Metode. Metode yang digunakan adalah metode eksperimen yang menguji validitas dan perbandingan teknik ELPLBA untuk pembakuan teknik pengukuran folat serum.Hasil. Hasil isolasi dan pemurnian PIF menghasilkan kadar 3 tiga mg/mL. Identifikasi SDS-PAGE dan Western blot menunjukkan 3 tiga pita protein yang diperiksa adalah protein ikat folat. Validitas teknik uji keterulangan menunjukkan nilai yang dapat diterima CV.

Background. This study was aimed to standarized technique of folic acid level serum measurment using folate binding protein FBP that isolated and purified from fresh bovine milk with enzyme labeled protein ligand binding assay ELPLBA technique. Method in this study, we performed an experiment research validated dan compared measurement techniques of ELPLBA with competitive ELISA for the standardization of the serum folic acid measurement technique. Results. FBP concentration yielded from isolated and purification was resulted 3 mg mL. SDS PAGE and western blot result showed 3 three protein bands that was confirmed to be FBP. Validity test repeatability indicate an acceptable CV 10 , whereas reproducible test showed poor results over a 5 day period. The results of the accuracy test of the enzyme labeled protein ligand binding assay technique showed good accuration. Linearity test of two samples showed quite linear results. Comparison of folic acid level measurement in serum between ELPLBA and ELISA technique showed there is no difference between both technique based on independent test T test at 95 confidence level. Conclusion. the enzyme labeled protein ligand binding assay technique on serum folic acid measurements were quite valid dan equivalent to the results obtained by competitive ELISA techniques.

 File Digital: 1

Shelf
 T-Muhamad Arif Budiman.pdf :: Unduh

LOGIN required

 Metadata

No. Panggil : T-pdf
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Subjek :
Penerbitan : Depok: Fakultas Kedokteran Universitas Indonesia, 2017
Program Studi :
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : computer
Tipe Carrier : online resource
Deskripsi Fisik : xvi, 54 pages : illustration ; 28 cm + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI
  • Ketersediaan
  • Ulasan
No. Panggil No. Barkod Ketersediaan
T-pdf 15-22-77180548 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20455665