:: UI - Skripsi Membership :: Kembali

UI - Skripsi Membership :: Kembali

Komparasi perilaku struktur D-EBF material baja dan komposit (CFST) dengan memperhitungkan rigiditas sambungan menggunakan analisis pushover = Comparisons of the behavior structure D-EBF with steel and composite (CFST) materials and consider the rigidity connection using pushover analysis

Indradjati Rachmatullah; Henki Wibowo Ashadi, supervisor; Heru Purnomo, examiner; Sjahril A. Rahim, examiner (Fakultas Teknik Universitas Indonesia, 2017)

 Abstrak

Indonesia merupakan kawasan rawan gempa, struktur bangunan yang dibutuhkan harus memiliki kekuatan dan daktalitas yang memadai sesuai dengan aturan yang berlaku. Struktur bangunan dengan konfigurasi D-EBF merupakan salah satu solusi untuk struktur tahan gempa. Penggunaan material dan sambungan yang digunakan sangat mempengaruhi perilaku bangunan. Untuk mengetahui perilaku bangunan bisa menggunakan banyak metode dan salah satunya adalah pushover analysis.
Penelitian dilakukan dengan 2 buah aplikasi komputer yaitu ETABS sebagai pengecekan bangunan sesuai SNI dan Drain-2DX untuk melakukan analisis. Variasi material menggunakan baja WF dan komposit CFST membuktikan bahwa bangunan baja WF dengan luasan baja 2 kali lipat dari CFST lebih daktail tetapi tidak lebih kuat dan kaku dibandingkan CFST. Dengan rigiditas sambungan yang tinggi maka bangunan akan semakin kuat dan kaku tetapi daktalitas dari bangunan akan berkurang. Kekuatan dan kekakuan berbanding terbalik terhadap daktalitas. Pengaruh rigiditas sambungan untuk material baja WF dan CFST adalah sama.

Indonesia earthquake prone areas, building structures that are needed must have adequate strength and ductility in accordance with the applicable rules. Building structures with the configuration of D EBF is one solution for earthquake resistant structures. The use of materials and the connection that was used greatly influences the behaviour of the building. To know the behavior of the building could use a lot of mehtod and one of them was pushover analysis.
Research done with two fruity computer applications i.e ETABS as building appropriate checking rules and DRAIN 2DX to do anlysis. Variation of materials use WF steel and Composite CFST proves that steel buildings extents with WF steel two times of CFST more ductile but not stronger and stiffer than CFST. With the rigidity connection that high then the building will be more strong and stiff but ductility of the building wil be reduced. Strength and rigidity is inversely proportional against ductility. The influence of rigidity connection for materials WF Steel and CFST is the same.

 File Digital: 1

Shelf

 Metadata

No. Panggil : S68531
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Subjek :
Penerbitan : Depok: Fakultas Teknik Universitas Indonesia, 2017
Program Studi :
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : unmediated ; computer
Tipe Carrier : volume ; online resource
Deskripsi Fisik : xx, 338 pages : illustration ; 30 cm + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
No. Panggil No. Barkod Ketersediaan
S68531 14-19-519985082 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20456668